Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 6AG2232-4HD32-1XB0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 6AG2232-4HD32-1XB0

SIPLUS S7-1200 SM 1232 T1 rail based on 6ES7232-4HD32-0XB0 with conformal coating, -25…+60 °C, OT1 with ST1/2 (+70 °C für 10 minutes), S7-1200, analog output, SM 1232, 4 AQ, +/-10 V, 14-bit resolution, or 0-20 mA, 13-bit resolution:

SiemensMFR # 6AG2232-4HD32-1XB0SKU # CEY-8EF3B0388DFC
Product type designationSM 1232 AQ 4x 14 bit
based on6ES7232-4HD32-0XB0
Rated value (DC)24 V
Current consumption, typ.45 mA
from backplane bus 5 V DC, typ.80 mA
Power loss, typ.1.5 W
Share

About This Product

SIPLUS S7-1200 SM 1232 T1 rail based on 6ES7232-4HD32-0XB0 with conformal coating, -25…+60 °C, OT1 with ST1/2 (+70 °C für 10 minutes), S7-1200, analog output, SM 1232, 4 AQ, +/-10 V, 14-bit resolution, or 0-20 mA, 13-bit resolution:

Siemens 6AG2232-4HD32-1XB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationSM 1232 AQ 4x 14 bit
based on6ES7232-4HD32-0XB0
Supply voltage
Rated value (DC)24 V
Input current
Current consumption, typ.45 mA
from backplane bus 5 V DC, typ.80 mA
Power loss
Power loss, typ.1.5 W
Analog outputs
Number of analog outputs4; Current or voltage
Output ranges, voltage
-10 V to +10 VYes
Output ranges, current
0 to 20 mAYes
Load impedance (in rated range of output)
with voltage outputs, min.1 000 Ω
with current outputs, max.600 Ω
Cable length
shielded, max.100 m; shielded, twisted pair
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.14 bit; Voltage: 14 bit; Current : 13 bit
Errors/accuracies
Temperature error (relative to output range), (+/-)25 °C ±0.3%, to 55 °C ±0.6% total measurement range
Basic error limit (operational limit at 25 °C)
Voltage, relative to output range, (+/-)0.3 %
Current, relative to output range, (+/-)0.3 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Common mode voltage, max.12 V
Interrupts/diagnostics/status information
AlarmsYes
Diagnostics functionYes
Alarms
Diagnostic alarmYes
Diagnoses
Monitoring the supply voltageYes
Wire breakYes
short-circuitYes
Diagnostics indication LED
for status of the outputsYes
for maintenanceYes
Isolation
Isolation tested with750 V DC (type test) and according to EN 50155 (routine test)
Degree and class of protection
IP degree of protectionIP20
Standards, approvals, certificates
CE markYes
Ecological footprint
environmental product declarationYes
Global warming potential
— global warming potential, (total) [CO2 eq]36.4 kg
— global warming potential, (during production) [CO2 eq]7.46 kg
— global warming potential, (during operation) [CO2 eq]29.1 kg
— global warming potential, (after end of life cycle) [CO2 eq]-0.18 kg
Railway application
EN 50121-3-2Yes; EMC for rail vehicles
EN 50121-4Yes; EMC for signal and telecommunications systems
EN 50124-1Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC
EN 50125-1Yes; Rail vehicles - see ambient conditions
EN 50125-2Yes; Stationary electrical equipment - see ambient conditions
EN 50125-3Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)
EN 50155Yes; Rail vehicles - temperature class OT1, ST1/ST2, horizontal mounting position
EN 61373Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B
Fire protection acc. to EN 45545-2Yes; For proof of conformity, see Service & Support
Free fall
Fall height, max.0.3 m; five times, in product package
Ambient temperature during operation
horizontal installation, min.-25 °C; = Tmin (incl. condensation/frost)
horizontal installation, max.60 °C; = Tmax; +70 °C for 10 min (OT1, ST1/ST2 acc. to EN 50155)
vertical installation, min.-25 °C; = Tmin
vertical installation, max.50 °C; = Tmax
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.2 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on land craft, rail vehicles and special-purpose vehicles
— to biologically active substances according to EN 60721-3-5Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request
— to chemically active substances according to EN 60721-3-5Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-5Yes; Class 5S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Electronic equipment on rolling stock acc. to EN 50155Yes; Class PC2 protective coating acc. to EN 50155:2017
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Connection method
required front connectorYes
Mechanics/material
plasticYes
Dimensions
Width45 mm
Height100 mm
Depth75 mm
Weights
Weight, approx.180 g
Other
Note:for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776

Related Products

1FY2901-0EB00
Siemens 1FY2901-0EB00
View Details

Siemens

1FY2901-0EB00

MFR #1FY2901-0EB00

SKU #YLSJVRF7YVE9X

1FN3050-8SA00-0AA0
View Details

Siemens

1FN3050-8SA00-0AA0

MFR #1FN3050-8SA00-0AA0

SKU #YLSPEYTCHSLPEPH

1FN3100-8SA00-0AA0
View Details

Siemens

1FN3100-8SA00-0AA0

MFR #1FN3100-8SA00-0AA0

SKU #YLSJZNRPZ4VXXL

1FN3150-8SA00-0AA0
View Details

Siemens

1FN3150-8SA00-0AA0

MFR #1FN3150-8SA00-0AA0

SKU #YLSZOWEGFUAGXOH

1FN3300-8SA00-0AA0
View Details

Siemens

1FN3300-8SA00-0AA0

MFR #1FN3300-8SA00-0AA0

SKU #YLSZMAEBPCROKIZ

1FN3450-8SA00-0AA0
View Details

Siemens

1FN3450-8SA00-0AA0

MFR #1FN3450-8SA00-0AA0

SKU #YLSNONBMS6EF28

1FN3600-8SA00-0AA0
View Details

Siemens

1FN3600-8SA00-0AA0

MFR #1FN3600-8SA00-0AA0

SKU #YLS8CPR47M6DMNJ

1FN3900-8SA00-0AA0
View Details

Siemens

1FN3900-8SA00-0AA0

MFR #1FN3900-8SA00-0AA0

SKU #YLSQEN1CGSWWALU

1FY2105-0AA00
View Details

Siemens

1FY2105-0AA00

MFR #1FY2105-0AA00

SKU #YLSGTZWOTRQID

1FY2105-4AA00
View Details

Siemens

1FY2105-4AA00

MFR #1FY2105-4AA00

SKU #YLSDLAYIMNHTZJE

Featured Products

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
View Details

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

AW20-N02CG-6CZ-B
SMC AW20-N02CG-6CZ-B
View Details

SMC

AW20-N02CG-6CZ-B

MFR #AW20-N02CG-6CZ-B

SKU #YLSNOOF0IBCZ3J3

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

MXS-AS16L
SMC MXS-AS16L
View Details

SMC

MXS-AS16L

MFR #MXS-AS16L

SKU #YLSAP0XXFGFSWY6

MXQ25L-40B-M9NZ
SMC MXQ25L-40B-M9NZ
View Details

SMC

MXQ25L-40B-M9NZ

MFR #MXQ25L-40B-M9NZ

SKU #YLSD1VANMRI726Z

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

Related Searches