Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 6AG1416-3XS07-7AB0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 6AG1416-3XS07-7AB0

SIPLUS S7-400 CPU 416-3 based on 6ES7416-3XS07-0AB0 with conformal coating, -25…+70 °C, central processing unit with: work memory 16 MB, (8 MB code, 8 MB data), interfaces 1st interface MPI/DP 12 Mbps, 2nd interface PROFIBUS DP, 3rd interface plug-in IFM module

SiemensMFR # 6AG1416-3XS07-7AB0SKU # YLSZSX5PG1IEAV
Product type designationCPU 416-3
HW functional status01
Firmware versionV7.0
based on6ES7416-3XS07-0AB0
Isochronous modeYes; For PROFIBUS only
Programming packageSTEP 7 V5.4 or higher with HSP 261
Share

About This Product

SIPLUS S7-400 CPU 416-3 based on 6ES7416-3XS07-0AB0 with conformal coating, -25…+70 °C, central processing unit with: work memory 16 MB, (8 MB code, 8 MB data), interfaces 1st interface MPI/DP 12 Mbps, 2nd interface PROFIBUS DP, 3rd interface plug-in IFM module

Siemens 6AG1416-3XS07-7AB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationCPU 416-3
HW functional status01
Firmware versionV7.0
based on6ES7416-3XS07-0AB0
Product function
Isochronous modeYes; For PROFIBUS only
Engineering with
Programming packageSTEP 7 V5.4 or higher with HSP 261
CiR - Configuration in RUN
CiR synchronization time, basic load100 ms
CiR synchronization time, time per I/O byte10 µs
Supply voltage
Rated value (DC)Power supply via system power supply
Input current
from backplane bus 5 V DC, typ.1.1 A
from backplane bus 5 V DC, max.1.3 A
from backplane bus 24 V DC, max.450 mA; 150 mA per DP interface
from interface 5 V DC, max.90 mA; At each DP interface
Power loss
Power loss, typ.5.5 W
Storage
Type of memoryRAM
Work memory
integrated16 Mbyte
integrated (for program)8 Mbyte
integrated (for data)8 Mbyte
expandableNo
Load memory
expandable FEPROMYes; with Memory Card (FLASH)
expandable FEPROM, max.64 Mbyte
integrated RAM, max.1 Mbyte
expandable RAMYes; with Memory Card (RAM)
expandable RAM, max.64 Mbyte
Backup
presentYes
with batteryYes; all data
without batteryNo
Backup battery
Backup current, typ.180 µA; up to 40 °C
Backup current, max.850 µA
Backup time, max.Dealt with in the module data manual with the secondary conditions and the factors of influence
Feeding of external backup voltage to CPU5 V DC to 15 V DC
CPU processing times
for bit operations, typ.12.5 ns
for word operations, typ.12.5 ns
for fixed point arithmetic, typ.12.5 ns
for floating point arithmetic, typ.25 ns
DB
Number, max.10 000; Number range: 1 to 16000
Size, max.64 kbyte
FB
Number, max.5 000; Number range: 0 to 7999
Size, max.64 kbyte
FC
Number, max.5 000; Number range: 0 to 7999
Size, max.64 kbyte
OB
Number, max.see instruction list
Size, max.64 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs8; OB 10-17
Number of delay alarm OBs4; OB 20-23
Number of cyclic interrupt OBs9; OB 30-38 (shortest cycle that can be set = 500 µs)
Number of process alarm OBs8; OB 40-47
Number of DPV1 alarm OBs3; OB 55-57
Number of isochronous mode OBs4; OB 61-64
Number of multicomputing OBs1; OB 60
Number of background OBs1; OB 90
Number of startup OBs3; OB 100-102
Number of asynchronous error OBs9; OB 80-88
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class24
additional within an error OB2
S7 counter
Number2 048
Retentivity
— adjustableYes
— presetZ 0 to Z 7
Counting range
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 timer
Number2 048
Retentivity
— adjustableYes
— presetNo times retentive
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.Total working and load memory (with backup battery)
Flag
Size, max.16 kbyte; Size of bit memory address area
Retentivity availableYes
Retentivity presetMB 0 to MB 15
Number of clock memories8; in 1 memory byte
Local data
adjustable, max.32 kbyte
preset16 kbyte
I/O address area
Inputs16 kbyte
Outputs16 kbyte
Process image
Inputs, adjustable16 kbyte
Outputs, adjustable16 kbyte
Inputs, default512 byte
Outputs, default512 byte
consistent data, max.244 byte
Access to consistent data in process imageYes
Subprocess images
Number of subprocess images, max.15
Digital channels
Inputs131 072
— of which central131 072
Outputs131 072
— of which central131 072
Analog channels
Inputs8 192
— of which central8 192
Outputs8 192
— of which central8 192
Hardware configuration
Number of expansion units, max.21
connectable OPs95
MulticomputingYes; 4 CPUs max. (with UR1 or UR2)
Interface modules
Number of connectable IMs (total), max.6
Number of connectable IM 460s, max.6
Number of connectable IM 463s, max.4; IM 463-2
Number of DP masters
integrated2
via CP10; CP 443-5 Extended
via IM 4674
Mixed mode IM + CP permittedNo; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode
via interface module1
Number of pluggable S5 modules (via adapter capsule in central device), max.6
Number of IO Controllers
Integrated0
Via CP4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
Number of operable FMs and CPs (recommended)
FMLimited by number of slots and number of connections
CP, PtPCP 440: Limited by number of slots; CP 441: limited by number of connections
PROFIBUS and Ethernet CPs14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller
Slots
required slots2
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Resolution1 ms
Deviation per day (buffered), max.1.7 s; Power off
Deviation per day (unbuffered), max.8.6 s; For power On
Operating hours counter
Number16
Number/Number range0 to 15
Range of valuesSFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
Granularity1 h
retentiveYes
Clock synchronization
supportedYes
to MPI, masterYes
on MPI, deviceYes
to DP, masterYes
on DP, deviceYes
in AS, masterYes
in AS, deviceYes
on Ethernet via NTPNo; Via CP
to IF 964 DPYes
Time difference in system when synchronizing via
MPI, max.200 ms
Interfaces
Interfaces/bus type1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 1 x PROFIBUS DP (optionally pluggable)
Number of RS 485 interfaces2; Combined MPI / PROFIBUS DP and PROFIBUS DP
Number of other interfaces1; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04-0AB0)
1. Interface
Interface typeMPI/PROFIBUS DP
IsolatedYes
Interface types
RS 485Yes
Output current of the interface, max.150 mA
Protocols
MPIYes
PROFIBUS DP masterYes
PROFIBUS DP deviceYes
MPI
Number of connections44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
PROFIBUS DP master
Number of connections, max.32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
Transmission rate, max.12 Mbit/s
max. number of DP devices32
Services
— PG/OP communicationYes
— RoutingYes; S7 routing
— Global data communicationNo
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— EquidistanceYes
— Isochronous modeYes
— SYNC/FREEZEYes
— activation/deactivation of DP devicesYes
— Direct data exchange (slave-to-slave communication)Yes
— DPV1Yes
Address area
— Inputs, max.2 kbyte
— Outputs, max.2 kbyte
User data per DP device
— user data per DP device, max.244 byte
— Inputs, max.244 byte
— Outputs, max.244 byte
— Slots, max.244
— per slot, max.128 byte
PROFIBUS DP device
Number of connections32
Transmission rate, max.12 Mbit/s
automatic baud rate searchNo
Address area, max.32; Virtual slots
User data per address area, max.32 byte
— of which consistent, max.32 byte
Services
— PG/OP communicationYes; with interface active
— RoutingYes; with interface active
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— Direct data exchange (slave-to-slave communication)No
— DPV1No
Transfer memory
— Inputs244 byte
— Outputs244 byte
2. Interface
Interface typePROFIBUS DP
IsolatedYes
Interface types
RS 485Yes
Output current of the interface, max.150 mA
Protocols
PROFIBUS DP masterYes
PROFIBUS DP deviceYes
PROFIBUS DP master
Number of connections, max.32
Transmission rate, max.12 Mbit/s
max. number of DP devices125
Services
— PG/OP communicationYes
— RoutingYes; S7 routing
— Global data communicationNo
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— EquidistanceYes
— Isochronous modeYes
— SYNC/FREEZEYes
— activation/deactivation of DP devicesYes
— Direct data exchange (slave-to-slave communication)Yes
— DPV1Yes
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
User data per DP device
— user data per DP device, max.244 byte
— Inputs, max.244 byte
— Outputs, max.244 byte
— Slots, max.244
— per slot, max.128 byte
PROFIBUS DP device
Number of connections32
Transmission rate, max.12 Mbit/s
Address area, max.32
User data per address area, max.32 byte
— of which consistent, max.32 byte
Services
— RoutingYes; with interface active
Transfer memory
— Inputs244 byte
— Outputs244 byte
3. Interface
Interface typepluggable interface module (IF), technical data as for 2nd interface
Plug-in interface modulesIF 964-DP (MLFB: 6AG1964-2AA04-2AB0)
IsolatedYes
automatic detection of transmission rateNo
Interface types
RS 485Yes
Output current of the interface, max.150 mA
Protocols
MPINo
PROFIBUS DP masterYes
PROFIBUS DP deviceYes
PROFIBUS DP master
Number of connections, max.32
Transmission rate, max.12 Mbit/s
max. number of DP devices125
Services
— PG/OP communicationYes
— RoutingYes; S7 routing
— Global data communicationNo
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— EquidistanceYes
— Isochronous modeYes
— SYNC/FREEZEYes
— activation/deactivation of DP devicesYes
— Direct data exchange (slave-to-slave communication)Yes
— DPV0Yes
— DPV1Yes
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
User data per DP device
— user data per DP device, max.244 byte
— Inputs, max.244 byte
— Outputs, max.244 byte
— Slots, max.244
— per slot, max.128 byte
PROFIBUS DP device
Number of connections32
Transmission rate, max.12 Mbit/s
automatic baud rate searchNo
Address area, max.32
User data per address area, max.32 byte
— of which consistent, max.32 byte
Services
— PG/OP communicationYes
— RoutingYes; with interface active
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— Direct data exchange (slave-to-slave communication)No
— DPV1No
Transfer memory
— Inputs244 byte
— Outputs244 byte
SIMATIC communication
S7 routingYes
Open IE communication
ISO-on-TCP (RFC1006)Via CP 443-1 and loadable FB
— Data length, max.1 452 bytes via CP 443-1 Adv.
Web server
supportedNo
Isochronous mode
EquidistanceYes
Number of DP masters with isochronous mode3
payload per isochronous device, max.244 byte
shortest clock pulse1 ms; 0.5 ms without use of SFC 126, 127
max. cycle32 ms
Communication functions
PG/OP communicationYes
Number of connectable OPs with message processing95; When using Alarm_S/SQ and Alarm_D/DQ
Number of connectable OPs without message processing95
Data record routingYes
Global data communication
supportedYes
Number of GD loops, max.16
Number of GD packets, transmitter, max.16
Number of GD packets, receiver, max.32
Size of GD packets, max.54 byte
Size of GD packet (of which consistent), max.1 variable
S7 basic communication
supportedYes
User data per job, max.76 byte
User data per job (of which consistent), max.1 variable
S7 communication
supportedYes
as serverYes
as clientYes
User data per job, max.64 kbyte
User data per job (of which consistent), max.462 byte; 1 variable
S5 compatible communication
supportedYes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
User data per job, max.8 kbyte
User data per job (of which consistent), max.240 byte
Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.64/64
Standard communication (FMS)
supportedYes; Via CP and loadable FB
Number of connections
overall96
usable for PG communication95
— reserved for PG communication1
— adjustable for PG communication, max.0
usable for OP communication95
— reserved for OP communication1
— adjustable for OP communication, max.0
usable for S7 basic communication94
— reserved for S7 basic communication0
— adjustable for S7 basic communication, max.0
usable for S7 communication94
— reserved for S7 communication0
— adjustable for S7 communication, max.0
usable for routing47
— reserved for routing0
— adjustable for routing, max.0
S7 message functions
Number of login stations for message functions, max.95; Max. 95 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
Symbol-related messagesYes
SCAN procedureYes
Program alarmsYes
Process diagnostic messagesYes
simultaneously active Alarm_S blocks, max.1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
Alarm 8-blocksYes
Number of instances for alarm 8 and S7 communication blocks, max.4 000
preset, max.600
Process control messagesYes
Number of archives that can log on simultaneously (SFB 37 AR_SEND)32
Number of messages
overall, max.1 024
in 100 ms grid, max.128
in 500 ms grid, max.512
in 1000 ms grid, max.1 024
Number of additional values
with 100 ms grid, max.1
with 500, 1000 ms grid, max.10
Test commissioning functions
Status blockYes; Up to 16 simultaneously
Single stepYes
Number of breakpoints16
Status/control
Status/control variableYes; Up to 16 variable tables
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.70; Status/control
Forcing
ForcingYes
Forcing, variablesInputs, outputs, bit memories, peripheral inputs, peripheral outputs
Number of variables, max.512
Diagnostic buffer
presentYes
Number of entries, max.3 200
— can be setYes
— preset120
Service data
Can be read outYes
Ambient temperature during operation
min.-25 °C; = Tmin
max.70 °C; = Tmax
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Configuration software
STEP 7Yes
Programming
Command setsee instruction list
Nesting levels7
Access to consistent data in process imageYes
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Number of simultaneously active SFCs
— DPSYC_FR2; SFC 11; per interface
— D_ACT_DP8; SFC 12; per interface
— RD_REC8; SFC 59; per interface
— WR_REC8; SFC 58; per interface
— WR_PARM8; SFC 55; per interface
— PARM_MOD1; SFC 57; per interface
— WR_DPARM2; SFC 56; per interface
— DPNRM_DG8; SFC 13; per interface
— RDSYSST8; SFC 51
— DP_TOPOL1; SFC 103; per interface
Number of simultaneously active SFBs
— RDREC8; SFB 52; per interface, but not more than 32 across all external interfaces
— WRREC8; SFB 53; per interface, but not more than 32 across all external interfaces
Know-how protection
User program protection/password protectionYes
Block encryptionYes; With S7 block Privacy
Dimensions
Width50 mm
Height290 mm
Depth219 mm
Weights
Weight, approx.900 g

Accessories 2

Genuine accessories that can be used with the Siemens 6AG1416-3XS07-7AB0 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
9LF1110-6DA13-2AB1Servis · Service Card
9TF6276-2XA11-1AL4Servis

Related Products

1FY2901-0EB00
Siemens 1FY2901-0EB00
View Details

Siemens

1FY2901-0EB00

MFR #1FY2901-0EB00

SKU #YLSJVRF7YVE9X

1FN3050-8SA00-0AA0
View Details

Siemens

1FN3050-8SA00-0AA0

MFR #1FN3050-8SA00-0AA0

SKU #YLSPEYTCHSLPEPH

1FN3100-8SA00-0AA0
View Details

Siemens

1FN3100-8SA00-0AA0

MFR #1FN3100-8SA00-0AA0

SKU #YLSJZNRPZ4VXXL

1FN3150-8SA00-0AA0
View Details

Siemens

1FN3150-8SA00-0AA0

MFR #1FN3150-8SA00-0AA0

SKU #YLSZOWEGFUAGXOH

1FN3300-8SA00-0AA0
View Details

Siemens

1FN3300-8SA00-0AA0

MFR #1FN3300-8SA00-0AA0

SKU #YLSZMAEBPCROKIZ

1FN3450-8SA00-0AA0
View Details

Siemens

1FN3450-8SA00-0AA0

MFR #1FN3450-8SA00-0AA0

SKU #YLSNONBMS6EF28

1FN3600-8SA00-0AA0
View Details

Siemens

1FN3600-8SA00-0AA0

MFR #1FN3600-8SA00-0AA0

SKU #YLS8CPR47M6DMNJ

1FN3900-8SA00-0AA0
View Details

Siemens

1FN3900-8SA00-0AA0

MFR #1FN3900-8SA00-0AA0

SKU #YLSQEN1CGSWWALU

1FY2105-0AA00
View Details

Siemens

1FY2105-0AA00

MFR #1FY2105-0AA00

SKU #YLSGTZWOTRQID

1FY2105-4AA00
View Details

Siemens

1FY2105-4AA00

MFR #1FY2105-4AA00

SKU #YLSDLAYIMNHTZJE

Featured Products

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
View Details

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

MXQ25L-40B-M9NZ
SMC MXQ25L-40B-M9NZ
View Details

SMC

MXQ25L-40B-M9NZ

MFR #MXQ25L-40B-M9NZ

SKU #YLSD1VANMRI726Z

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
View Details

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

CG5EN50SV-150
SMC CG5EN50SV-150
View Details

SMC

CG5EN50SV-150

MFR #CG5EN50SV-150

SKU #YLST11TLVYPVP7H

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

Related Searches