Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 6AG1410-5HX08-7AB0

SIPLUS PCS 7 CPU 410-5H based on 6ES7410-5HX08-0AB0 with conformal coating, -25…+70 °C, central processing unit for S7-400 and S7-400H/F/FH, 5 interfaces: 1x PN, 1x DP, 2x for Sync modules and 1x service . only for spare parts supply; without System Expansion Card

SiemensMFR # 6AG1410-5HX08-7AB0SKU # CEY-8EF3B03886D3
Product type designationCPU 410-5H
Design of PLC basic unitwith conformal coating
based on6ES7410-5HX08-0AB0
Field interface securityYes
CiR synchronization time, basic load60 ms
from backplane bus 5 V DC, typ.2 A
Share

About This Product

SIPLUS PCS 7 CPU 410-5H based on 6ES7410-5HX08-0AB0 with conformal coating, -25…+70 °C, central processing unit for S7-400 and S7-400H/F/FH, 5 interfaces: 1x PN, 1x DP, 2x for Sync modules and 1x service . only for spare parts supply; without System Expansion Card

Siemens 6AG1410-5HX08-7AB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationCPU 410-5H
Design of PLC basic unitwith conformal coating
based on6ES7410-5HX08-0AB0
Product function
SysLogYes; via TCP; up to 4 receivers can be parameterized; buffer capacity max. 3 200 entries
Field interface securityYes
Engineering with
Programming packagefrom SIMATIC PCS 7 V10.0.1 (HSP 324, 325, 326)
CiR - Configuration in RUN
CiR synchronization time, basic load60 ms
CiR synchronization time, time per I/O byte0 µs
Input current
from backplane bus 5 V DC, typ.2 A
from backplane bus 5 V DC, max.2.4 A
from backplane bus 24 V DC, max.150 mA; DP interface
from interface 5 V DC, max.90 mA; At the DP interface
Power loss
Power loss, typ.10 W
Processor
CPU speed450 MHz; Multi-processor system
Storage
PCS 7 process objects100 ... approx. 2 600, adjustable with System Expansion Card
Work memory
integrated32 Mbyte; max., dependent on the System Expansion Card used
integrated (for program)Dependent on the System Expansion Card used
integrated (for data)Dependent on the System Expansion Card used
expandableDependent on the System Expansion Card used
Load memory
integrated RAM, max.48 Mbyte
expandable RAMNo
Backup
with batteryYes; all data
without batteryYes; Program and data of the load memory
Backup battery
Backup current, typ.370 µA; Valid up to 40°C
Backup current, max.2.1 mA
Backup time, max.Dealt with in the module data manual with the secondary conditions and the factors of influence
Feeding of external backup voltage to CPUNo
CPU processing times
for bit operations, typ.7.5 ns
for word operations, typ.7.5 ns
for fixed point arithmetic, typ.7.5 ns
for floating point arithmetic, typ.15 ns
average processing time of PCS 7 typicals110 µs; with APL Typicals
Process tasks, max.9; Individually adjustable from 10 ms to 5 s
DB
Number, max.16 000; Number range: 1 to 16 000 (= Instances)
Size, max.64 kbyte
FB
Number, max.8 000; Number range: 0 to 7999
Size, max.64 kbyte
FC
Number, max.8 000; Number range: 0 to 7999
Size, max.64 kbyte
OB
Number, max.see instruction list
Size, max.64 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs8; OB 10-17
Number of delay alarm OBs4; OB 20-23
Number of cyclic interrupt OBs9; OB 30-38 (= Process Tasks)
Number of process alarm OBs8; OB 40-47
Number of DPV1 alarm OBs3; OB 55-57
Number of startup OBs2; OB 100, 102
Number of asynchronous error OBs9; OB 80-88
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class24
additional within an error OB2
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.Total working and load memory (with backup battery)
Flag
Size, max.16 384 byte
Retentivity availableYes
Number of clock memories8; in 1 memory byte
Local data
adjustable, max.64 kbyte
I/O address area
Inputs16 kbyte; max., dependent on the System Expansion Card used
Outputs16 kbyte; max., dependent on the System Expansion Card used
Process image
Inputs, default16 kbyte; Dependent on the System Expansion Card used
Outputs, default16 kbyte; Dependent on the System Expansion Card used
consistent data, max.244 byte
Access to consistent data in process imageYes
Subprocess images
Number of subprocess images, max.15
Hardware configuration
Number of expansion units, max.21; S7-400 expansion devices
connectable OPs119
MulticomputingNo
Interface modules
Number of connectable IMs (total), max.6
Number of connectable IM 460s, max.6
Number of connectable IM 463s, max.4; Single mode only
Number of DP masters
integrated1
via CP10; CP 443-5 Extended
Number of IO Controllers
Integrated2
Via CP0
Number of operable FMs and CPs (recommended)
PROFIBUS and Ethernet CPs11; Of which max. 10 CP as DP master
Slots
required slots2
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Resolution1 ms
Deviation per day (buffered), max.1.7 s; Power off
Deviation per day (unbuffered), max.8.6 s; Power on
Operating hours counter
Number16
Number/Number range0 to 15
Range of valuesSFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
Granularity1 h
retentiveYes
Clock synchronization
supportedYes
to DP, masterYes
on DP, deviceYes
in AS, masterYes
in AS, deviceYes
on Ethernet via NTPNTP as client and as server/client via SIMATIC procedure
Interfaces
Number of PROFINET interfaces2
Number of RS 485 interfaces1; PROFIBUS DP
Number of other interfaces2; 2x synchronization
1. Interface
Interface typeRS 485 / PROFIBUS
IsolatedYes
Number of connections16
Interface types
Output current of the interface, max.150 mA
Protocols
PROFIBUS DP masterYes
PROFIBUS DP deviceNo
PROFIBUS DP master
Number of connections, max.16
Transmission rate, max.12 Mbit/s
max. number of DP devices96
Number of slots per interface, max.1 632
Services
— PG/OP communicationYes
— RoutingYes; S7 routing
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— EquidistanceNo
— Isochronous modeNo
— SYNC/FREEZENo
— activation/deactivation of DP devicesYes; Approved for stand-alone operation only, not in conjunction with CiR (Configuration in Run)
— Direct data exchange (slave-to-slave communication)No
— DPV1Yes
Address area
— Inputs, max.6 kbyte
— Outputs, max.6 kbyte
User data per DP device
— user data per DP device, max.244 byte
— Inputs, max.244 byte
— Outputs, max.244 byte
— Slots, max.244
— per slot, max.128 byte
2. Interface
Interface typePROFINET
IsolatedYes
automatic detection of transmission rateYes; Autosensing
AutonegotiationYes
AutocrossingYes
System redundancyYes
Redundant subnetworksYes
Change of IP address at runtime, supportedNo
Number of connections120
Interface types
Number of ports2
integrated switchYes
Protocols
PROFINET IO ControllerYes
PROFINET IO DeviceNo
PROFINET CBANo
Open IE communicationYes
Web serverNo
Media redundancyYes
PROFINET IO Controller
Transmission rate, max.100 Mbit/s
Services
— PG/OP communicationYes
— S7 communicationYes
— Shared deviceNo; however, usable as part of S7
— Prioritized startupNo
— Number of connectable IO Devices, max.250
— Number of connectable IO Devices for RT, max.250
— of which in line, max.250
— Activation/deactivation of IO DevicesYes; Approved for stand-alone operation only, not in conjunction with CiR (Configuration in Run)
— IO Devices changing during operation (partner ports), supportedNo
— Device replacement without swap mediumYes
— Send cycles250 µs, 500 µs, 1 ms, 2 ms, 4 ms
— Updating time250 µs to 512 ms, minimum value depends on the number of configured user data and the configured single or redundant mode
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
— User data consistency, max.1 024 byte
Open IE communication
Number of connections, max.118
Local port numbers used at the system end0, 20, 21, 25, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535
Keep-alive function, supportedYes
3. Interface
Interface typePROFINET
IsolatedYes
automatic detection of transmission rateYes; Autosensing
AutonegotiationYes
AutocrossingYes
System redundancyYes
Redundant subnetworksYes
Number of connections120
Interface types
Number of ports2
integrated switchYes
Protocols
PROFINET IO ControllerYes
PROFINET IO deviceNo
PROFINET CBANo
Open IE communicationYes
Web serverNo
Media redundancyYes
PROFINET IO Controller
Transmission rate, max.100 Mbit/s
Services
— PG/OP communicationYes
— S7 communicationYes
— Shared deviceNo; however, usable as part of S7
— Prioritized startupNo
— Number of connectable IO Devices, max.250
— Number of connectable IO Devices for RT, max.250
— of which in line, max.250
— Activation/deactivation of IO DevicesYes; Approved for stand-alone operation only, not in conjunction with CiR (Configuration in Run)
— IO Devices changing during operation (partner ports), supportedNo
— Device replacement without swap mediumYes
— Send cycles250 µs, 500 µs, 1 ms, 2 ms, 4 ms
— Updating time250 µs to 512 ms, minimum value depends on the number of configured user data and the configured single or redundant mode
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
— User data consistency, max.1 024 byte
Open IE communication
Number of connections, max.118
Local port numbers used at the system end0, 20, 21, 25, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535
Keep-alive function, supportedYes
4. Interface
Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization modules 6AG1960-1AA06-7XA0 or 6AG1960-1AB06-7XA0
5. Interface
Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization modules 6AG1960-1AA06-7XA0 or 6AG1960-1AB06-7XA0
Protocols
Supports protocol for PROFINET IOYes
PROFINET CBANo
PROFIsafeYes
PROFIBUSYes
AS-InterfaceYes; Via add-on
Media redundancy
— Switchover time on line break, typ.< 200 ms
— Number of stations in the ring, max.50
SIMATIC communication
S7 routingYes
Open IE communication
TCP/IPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.118
— Data length, max.32 kbyte
— several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs
— Number of connections, max.118
— Data length, max.32 kbyte; 1 452 bytes via CP 443-1 Adv.
UDPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.118
— Data length, max.1 472 byte
Further protocols
Foundation FieldbusYes; via DP/FF Link
MODBUSYes; Via add-on
Communication functions
PG/OP communicationYes
Number of connectable OPs with message processing119; When using Alarm_S/SQ and Alarm_D/DQ
Number of connectable OPs without message processing119
Data record routingYes
S7 communication
supportedYes
as serverYes
as clientYes
User data per job, max.64 kbyte
User data per job (of which consistent), max.462 byte; 1 variable
S5 compatible communication
supportedYes; via CP and FC AG_SEND and FC AG_RECV
User data per job, max.8 kbyte
User data per job (of which consistent), max.240 byte
Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.64/64
Standard communication (FMS)
supportedYes; Via CP and loadable FB
Number of connections
overall120
— reserved for PG communication1
— reserved for OP communication1
S7 message functions
Number of login stations for message functions, max.119; max. 119 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
Program alarmsYes
Process diagnostic messagesYes
simultaneously active Alarm_S blocks, max.1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
Alarm 8-blocksYes
Number of instances for alarm 8 and S7 communication blocks, max.10 000
Process control messagesYes
Number of archives that can log on simultaneously (SFB 37 AR_SEND)64
Test commissioning functions
Status blockYes
Single stepYes
Number of breakpoints4
Status/control
Status/control variableYes
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.70
Diagnostic buffer
presentYes
Number of entries, max.3 200
Service data
Can be read outYes
Ambient temperature during operation
min.-25 °C; = Tmin
max.70 °C; = Tmax
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m); with "F-System" applications max. +2 000 m above sea level permissible
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Programming
Command setsee instruction list
Nesting levels7
Access to consistent data in process imageYes
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
— SCLYes
— CFCYes
Number of simultaneously active SFCs
— RD_REC8; SFC 59; per interface
— WR_REC8; SFC 58; per interface
— WR_PARM8; SFC 55; per interface
— PARM_MOD1; SFC 57; per interface
— WR_DPARM2; SFC 56; per interface
— DPNRM_DG8; SFC 13; per interface
— RDSYSST8; SFC 51
— DP_TOPOL1; SFC 103; per interface
Number of simultaneously active SFBs
— RDREC8; SFB 52; per interface, but not more than 32 across all external interfaces
— WRREC8; SFB 53; per interface, but not more than 32 across all external interfaces
Know-how protection
User program protection/password protectionYes
Block encryptionYes; With S7 block Privacy
Dimensions
Width50 mm
Height290 mm
Depth219 mm
Weights
Weight, approx.1.1 kg

Related Products

1FY2901-0EB00
Siemens 1FY2901-0EB00
View Details

Siemens

1FY2901-0EB00

MFR #1FY2901-0EB00

SKU #YLSJVRF7YVE9X

1FN3050-8SA00-0AA0
View Details

Siemens

1FN3050-8SA00-0AA0

MFR #1FN3050-8SA00-0AA0

SKU #YLSPEYTCHSLPEPH

1FN3100-8SA00-0AA0
View Details

Siemens

1FN3100-8SA00-0AA0

MFR #1FN3100-8SA00-0AA0

SKU #YLSJZNRPZ4VXXL

1FN3150-8SA00-0AA0
View Details

Siemens

1FN3150-8SA00-0AA0

MFR #1FN3150-8SA00-0AA0

SKU #YLSZOWEGFUAGXOH

1FN3300-8SA00-0AA0
View Details

Siemens

1FN3300-8SA00-0AA0

MFR #1FN3300-8SA00-0AA0

SKU #YLSZMAEBPCROKIZ

1FN3450-8SA00-0AA0
View Details

Siemens

1FN3450-8SA00-0AA0

MFR #1FN3450-8SA00-0AA0

SKU #YLSNONBMS6EF28

1FN3600-8SA00-0AA0
View Details

Siemens

1FN3600-8SA00-0AA0

MFR #1FN3600-8SA00-0AA0

SKU #YLS8CPR47M6DMNJ

1FN3900-8SA00-0AA0
View Details

Siemens

1FN3900-8SA00-0AA0

MFR #1FN3900-8SA00-0AA0

SKU #YLSQEN1CGSWWALU

1FY2105-0AA00
View Details

Siemens

1FY2105-0AA00

MFR #1FY2105-0AA00

SKU #YLSGTZWOTRQID

1FY2105-4AA00
View Details

Siemens

1FY2105-4AA00

MFR #1FY2105-4AA00

SKU #YLSDLAYIMNHTZJE

Featured Products

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
View Details

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

AW20-N02CG-6CZ-B
SMC AW20-N02CG-6CZ-B
View Details

SMC

AW20-N02CG-6CZ-B

MFR #AW20-N02CG-6CZ-B

SKU #YLSNOOF0IBCZ3J3

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

Related Searches

Siemens 6AG1410-5HX08-7AB0 priceSiemens 6AG1410-5HX08-7AB0 quotebuy Siemens 6AG1410-5HX08-7AB06AG1410-5HX08-7AB0 price6AG1410-5HX08-7AB0 stock availabilitySiemens spare partsSiemens 6AG1410-5HX08-7AB0 equivalentSiemens 6AG1410-5HX08-7AB0 specifications