product brand nameSIPLUS
transfer rate
at the 1st interface10 ... 100 Mbit/s
interfaces
number of interfaces / according to Industrial Ethernet2
at the 1st interface / according to Industrial Ethernet2
for power supply1
of Industrial Ethernet interfaceRJ45 port
at the 1st interface / according to Industrial EthernetRJ45 port
for power supply2-pole plugable terminal block
supply voltage, current consumption, power loss
type of voltage / of the supply voltageDC
supply voltage / 1 / from backplane bus5 V
supply voltage24 V
supply voltage / external24 V
supply voltage / external / at DC / rated value24 V
relative positive tolerance / at DC / at 24 V20 %
relative negative tolerance / at DC / at 24 V15 %
from backplane bus / at DC / at 5 V / typical0.2 A
from external supply voltage / at DC / at 24 V / typical0.16 A
from external supply voltage / at DC / at 24 V / maximum0.2 A
power loss [W]5.8 W
ambient conditions
for vertical installation / during operation-25 ... +40 °C
for horizontally arranged busbars / during operation-25 ... +60 °C
during storage-40 ... +70 °C
during transport-40 ... +70 °C
installation altitude / at height above sea level / maximum5000 m
ambient condition / relating to ambient temperature - air pressure - installation altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
with condensation / according to IEC 60068-2-38 / maximum100 %; RH including condensation/frost (no commissioning when condensation is present), horizontal installation
chemical resistance / to commercially available cooling lubricantsYes; incl. airborne diesel and oil droplets
conformity according to EN 60721-3-3Yes; Class 3B2 mold and fungal spores (excluding fauna), Class 3B3 on request
conformity according to EN 60721-3-6Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna)
conformity according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray in accordance with EN 60068-2-52 (Severity 3). The supplied plug covers must remain in place on the unused interfaces during operation.
conformity according to EN 60721-3-6Yes
conformity according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation.
conformity according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation.
coating / for equipped printed circuit board / according to EN 61086Yes; Class 2 for high availability
type of coating / protection against pollution according to EN 60664-3Yes; Protection of the type 1
type of test / of the coating / according to MIL-I-46058CYes; Coating discoloration during service life possible
product conformity / of the coating / Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, class A
protection class IPIP20
design, dimensions and weights
module formatCompact module S7-300 single width
width40 mm
height125 mm
depth120 mm
net weight0.22 kg
S7-300 rail mountingYes
performance data / open communication
number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum8
as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum8 Kibyte
as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum8 Kibyte
as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum2 Kibyte
number of Multicast stations8
performance data / S7 communication
maximum4
of SIMATIC communication / as serverYes
performance data / multi-protocol mode
number of active connections / with multi-protocol mode12
performance data / PROFINET communication / as PN IO controller
product function / PROFINET IO controllerNo
performance data / PROFINET communication / as PN IO device
product function / PROFINET IO deviceYes
as user data for input variables / as PROFINET IO device / maximum512 byte
as user data for output variables / as PROFINET IO device / maximum512 byte
as user data for input variables / for each sub-module as PROFINET IO device240 byte
as user data for output variables / for each sub-module as PROFINET IO device240 byte
as user data for the consistency area for each sub-module240 byte
number of submodules / per PROFINET IO-Device32
performance data / telecontrol
TCP/IPYes
product functions / management, configuration, engineering
product function / MIB supportYes
SNMP v1Yes
DCPYes
LLDPYes
requiredSTEP 7 V5.4 or higher / STEP 7 Professional V11 (TIA Portal) or higher
I&M0 - device-specific informationYes
I&M1 - higher level designation/location designationYes
product functions / diagnostics
product function / web-based diagnosticsYes
product functions / switch
product feature / switchYes
switch-managedNo
with IRT / PROFINET IO switchNo
configuration with STEP 7Yes
product functions / redundancy
ring redundancyYes
redundancy managerNo
protocol / is supported / Media Redundancy Protocol (MRP)Yes
product functions / security
password protection for Web applicationsNo
ACL - IP-basedYes
ACL - IP-based for PLC/routingNo
switch-off of non-required servicesYes
blocking of communication via physical portsYes
log file for unauthorized accessNo
product functions / time
product function / SICLOCK supportYes
product function / pass on time synchronizationYes
NTPYes