Siemens 6AG1331-7KB02-2AB0

Replacement only, no repair. For new rail projects possibly migration to S7-1200, S7-1500, ET200SP SM 331 2 AI 20-pole based on 6ES7331-7KB02-0AB0 with conformal coating, -25…+70 °C, analog input isolated 2 AI, resolution 9/12/14 bits, U/I/thermocouple/resistor, alarm, diagnostics, 1x 20-pole, removing/inserting with active backplane bus

SiemensMFR # 6AG1331-7KB02-2AB0SKU # CEY-8EF3B0388707
based on6ES7331-7KB02-0AB0
Isochronous modeNo
Rated value (DC)24 V
Reverse polarity protectionYes
from backplane bus 5 V DC, max.50 mA
Power loss, typ.1.3 W
Share

About This Product

Replacement only, no repair. For new rail projects possibly migration to S7-1200, S7-1500, ET200SP SM 331 2 AI 20-pole based on 6ES7331-7KB02-0AB0 with conformal coating, -25…+70 °C, analog input isolated 2 AI, resolution 9/12/14 bits, U/I/thermocouple/resistor, alarm, diagnostics, 1x 20-pole, removing/inserting with active backplane bus

Siemens 6AG1331-7KB02-2AB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
based on6ES7331-7KB02-0AB0
Product function
Isochronous modeNo
Load voltage L+
Rated value (DC)24 V
Reverse polarity protectionYes
Input current
from load voltage L+ (without load), max.80 mA
from backplane bus 5 V DC, max.50 mA
Power loss
Power loss, typ.1.3 W
Analog inputs
Number of analog inputs2
For resistance measurement1
permissible input voltage for voltage input (destruction limit), max.20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)
permissible input current for current input (destruction limit), max.40 mA
Constant measurement current for resistance-type transmitter, typ.1.67 mA
Input ranges
VoltageYes
CurrentYes
ThermocoupleYes
Resistance thermometerYes
ResistanceYes
Input ranges (rated values), voltages
0 to +10 VNo
1 V to 5 VYes
— Input resistance (1 V to 5 V)100 kΩ
1 V to 10 VNo
-1 V to +1 VYes
— Input resistance (-1 V to +1 V)10 MΩ
-10 V to +10 VYes
— Input resistance (-10 V to +10 V)100 kΩ
-2.5 V to +2.5 VYes
— Input resistance (-2.5 V to +2.5 V)100 kΩ
-250 mV to +250 mVYes
— Input resistance (-250 mV to +250 mV)10 MΩ
-5 V to +5 VYes
— Input resistance (-5 V to +5 V)100 kΩ
-50 mV to +50 mVNo
-500 mV to +500 mVYes
— Input resistance (-500 mV to +500 mV)10 MΩ
-80 mV to +80 mVYes
— Input resistance (-80 mV to +80 mV)10 MΩ
Input ranges (rated values), currents
0 to 20 mAYes
— Input resistance (0 to 20 mA)25 Ω
-10 mA to +10 mAYes
— Input resistance (-10 mA to +10 mA)25 Ω
-20 mA to +20 mAYes
— Input resistance (-20 mA to +20 mA)25 Ω
-3.2 mA to +3.2 mAYes
— Input resistance (-3.2 mA to +3.2 mA)25 Ω
4 mA to 20 mAYes
— Input resistance (4 mA to 20 mA)25 Ω
Input ranges (rated values), thermocouples
Type EYes
— Input resistance (Type E)10 MΩ
Type JYes
— Input resistance (type J)10 MΩ
Type KYes
— Input resistance (Type K)10 MΩ
Type LNo
Type NYes
— Input resistance (Type N)10 MΩ
Type RNo
Type SNo
Type TNo
Type UNo
Type TXK/TXK(L) to GOSTNo
Input ranges (rated values), resistance thermometer
Cu 10No
Ni 100Yes
— Input resistance (Ni 100)10 MΩ; Standard
Pt 100Yes
— Input resistance (Pt 100)10 kΩ; Standard
Input ranges (rated values), resistors
0 to 150 ohmsYes
— Input resistance (0 to 150 ohms)10 MΩ
0 to 300 ohmsYes
— Input resistance (0 to 300 ohms)10 MΩ
0 to 600 ohmsYes
— Input resistance (0 to 600 ohms)10 MΩ
0 to 6000 ohmsNo
Temperature compensation
— ParameterizableYes
— internal temperature compensationYes
— external temperature compensation with compensations socketYes
— for definable comparison point temperatureYes
Characteristic linearization
ParameterizableYes
— for thermocouplesType E, J, K, L, N
— for resistance thermometerPt100 (standard, climatic range), Ni100 (standard, climatic range)
Cable length
shielded, max.200 m; 50 m at 80 mV and thermocouples
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.15 bit; Unipolar: 9/12/12/14 bit; bipolar: 9 bit + sign/12 bit + sign/12 bit + sign/14 bit + sign
Integration time, parameterizableYes; 2,5 / 16,67 / 20 / 100 ms
Interference voltage suppression for interference frequency f1 in Hz400 / 60 / 50 / 10 Hz
Connection of signal encoders
for voltage measurementYes
for current measurement as 2-wire transducerYes
for current measurement as 4-wire transducerYes
for resistance measurement with two-wire connectionYes
for resistance measurement with three-wire connectionYes
for resistance measurement with four-wire connectionYes
Operational error limit in overall temperature range
Voltage, relative to input range, (+/-)1 %; ±1% (80 mV); ±0.6% (250 mV to 1 000 mV); ±0.8% (2.5 V to 10 V) @ 0 ... +60 °C; ±1.3% (80 mV); ±0.8% (250 mV to 1 000 mV); ±1% (2.5 V to 10 V) @ -25 ... +70 °C
Current, relative to input range, (+/-)0.7 %; @ 0 ... +60 °C; ±0.9% @ -25 ... +70 °C; from 3.2 mA to 20 mA
Resistance, relative to input range, (+/-)0.7 %; @ 0 ... +60 °C; ±0.9% @ -25 ... +70 °C; 150, 300, 600 ohm
Resistance thermometer, relative to input range, (+/-)0.7 %; ±0.7 % (Pt100 / Ni100); ±0.8 % (Pt100 climate) @ 0 ... +60 °C; ±0.9 % (Pt100 / Ni100); ±1 % (Pt100 climate) @ -25 ... +70 °C
Thermocouple, relative to input range, (+/-)1.1 %; @ 0 ... +60 °C; 1.3% @ -25 ... +70 °C; type E, J, K, L, N
Basic error limit (operational limit at 25 °C)
Voltage, relative to input range, (+/-)0.6 %; ±0.6% (80 mV, 2.5 V to 10 V); ±0.4% (250 mV to 1 000 mV)
Current, relative to input range, (+/-)0.5 %; 3.2 to 20 mA
Resistance, relative to input range, (+/-)0.5 %; 150, 300, 600 Ohm
Resistance thermometer, relative to input range, (+/-)0.6 %; ±0.5% (Pt100/ Ni100), ±0.6% (Pt100 climate)
Thermocouple, relative to input range, (+/-)0.7 %; Type E, N, J, K, L
Interrupts/diagnostics/status information
Diagnostics functionYes; Parameterizable
Alarms
Diagnostic alarmYes
Limit value alarmYes; Parameterizable, channel 0
Diagnoses
Diagnostic information readableYes
Diagnostics indication LED
Group error SF (red)Yes
Potential separation analog inputs
between the channelsNo
between the channels and backplane busYes
between the channels and the power supply of the electronicsYes; Not for 2-wire transmitters
Isolation
Isolation tested with500 V DC
Standards, approvals, certificates
CE markYes
UL approvalYes; File E239877
RCM (formerly C-TICK)Yes
KC approvalYes
EAC (formerly Gost-R)Yes
Railway application
EN 50121-4No
EN 50155No
Ambient temperature during operation
min.-25 °C; = Tmin
max.70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Connection method
required front connector20-pin
Dimensions
Width40 mm
Height125 mm
Depth120 mm
Weights
Weight, approx.250 g

Accessories 2

Genuine accessories that can be used with the Siemens 6AG1331-7KB02-2AB0 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
6ES7392-1AJ00-0AA0Aksesuar · Connection plug
6ES7392-1BJ00-0AA0Aksesuar · Connection plug

Related Products

1FY2901-0EB00
Siemens 1FY2901-0EB00
View Details

Siemens

1FY2901-0EB00

MFR #1FY2901-0EB00

SKU #YLSJVRF7YVE9X

1FN3050-8SA00-0AA0
View Details

Siemens

1FN3050-8SA00-0AA0

MFR #1FN3050-8SA00-0AA0

SKU #YLSPEYTCHSLPEPH

1FN3100-8SA00-0AA0
View Details

Siemens

1FN3100-8SA00-0AA0

MFR #1FN3100-8SA00-0AA0

SKU #YLSJZNRPZ4VXXL

1FN3150-8SA00-0AA0
View Details

Siemens

1FN3150-8SA00-0AA0

MFR #1FN3150-8SA00-0AA0

SKU #YLSZOWEGFUAGXOH

1FN3300-8SA00-0AA0
View Details

Siemens

1FN3300-8SA00-0AA0

MFR #1FN3300-8SA00-0AA0

SKU #YLSZMAEBPCROKIZ

1FN3450-8SA00-0AA0
View Details

Siemens

1FN3450-8SA00-0AA0

MFR #1FN3450-8SA00-0AA0

SKU #YLSNONBMS6EF28

1FN3600-8SA00-0AA0
View Details

Siemens

1FN3600-8SA00-0AA0

MFR #1FN3600-8SA00-0AA0

SKU #YLS8CPR47M6DMNJ

1FN3900-8SA00-0AA0
View Details

Siemens

1FN3900-8SA00-0AA0

MFR #1FN3900-8SA00-0AA0

SKU #YLSQEN1CGSWWALU

1FY2105-0AA00
View Details

Siemens

1FY2105-0AA00

MFR #1FY2105-0AA00

SKU #YLSGTZWOTRQID

1FY2105-4AA00
View Details

Siemens

1FY2105-4AA00

MFR #1FY2105-4AA00

SKU #YLSDLAYIMNHTZJE

Featured Products

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
View Details

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

CG5EN50SV-150
SMC CG5EN50SV-150
View Details

SMC

CG5EN50SV-150

MFR #CG5EN50SV-150

SKU #YLST11TLVYPVP7H

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

Related Searches

Siemens 6AG1331-7KB02-2AB0 priceSiemens 6AG1331-7KB02-2AB0 quotebuy Siemens 6AG1331-7KB02-2AB06AG1331-7KB02-2AB0 price6AG1331-7KB02-2AB0 stock availabilitySiemens spare partsSiemens 6AG1331-7KB02-2AB0 equivalentSiemens 6AG1331-7KB02-2AB0 specifications