Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 6AG1317-6FF04-2AB0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 6AG1317-6FF04-2AB0

For new rail projects possibly migration to S7-1200, S7-1500, ET200SP CPU 317F-2DP based on 6ES7317-6FF04-0AB0 with conformal coating, -25…+60 °C, central processing unit with 1.5 MB work memory, 1st interface MPI/DP 12 Mbps, 2nd interface DP master/ device, Micro Memory Card required can be used with software package S7 Distributed Safety V5.2 SP1 or higher

SiemensMFR # 6AG1317-6FF04-2AB0SKU # CEY-8EF3B0388728
Product type designationCPU 317F-2 DP
based on6ES7317-6FF04-0AB0
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Current consumption (rated value)870 mA
Share

About This Product

For new rail projects possibly migration to S7-1200, S7-1500, ET200SP CPU 317F-2DP based on 6ES7317-6FF04-0AB0 with conformal coating, -25…+60 °C, central processing unit with 1.5 MB work memory, 1st interface MPI/DP 12 Mbps, 2nd interface DP master/ device, Micro Memory Card required can be used with software package S7 Distributed Safety V5.2 SP1 or higher

Siemens 6AG1317-6FF04-2AB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationCPU 317F-2 DP
based on6ES7317-6FF04-0AB0
Engineering with
Programming packageSTEP 7 V5.5 + SP1 or higher or STEP 7 V5.2 + SP1 or higher with HSP 202 + Distributed Safety
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)2 A min.
Input current
Current consumption (rated value)870 mA
Current consumption (in no-load operation), typ.120 mA
Inrush current, typ.4 A
I²t1 A²·s
Power loss
Power loss, typ.4.5 W
Work memory
integrated1 536 kbyte
expandableNo
Load memory
Plug-in (MMC)Yes
Plug-in (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 a
Backup
presentYes; Guaranteed by MMC (maintenance-free)
without batteryYes; Program and data
CPU processing times
for bit operations, typ.0.025 µs
for word operations, typ.0.03 µs
for fixed point arithmetic, typ.0.04 µs
for floating point arithmetic, typ.0.16 µs
CPU-blocks
Number of elements (total)2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
Number, max.2 048; Number range: 1 to 16000
Size, max.64 kbyte
FB
Number, max.2 048; Number range: 0 to 7999
Size, max.64 kbyte
FC
Number, max.2 048; Number range: 0 to 7999
Size, max.64 kbyte
OB
Number, max.see instruction list
Size, max.64 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs2; OB 20, 21
Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
Number of process alarm OBs1; OB 40
Number of DPV1 alarm OBs3; OB 55, 56, 57
Number of isochronous mode OBs1; OB 61
Number of startup OBs1; OB 100
Number of asynchronous error OBs5; OB 80, 82, 85, 86, 87
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class16
additional within an error OB4
S7 counter
Number512
Retentivity
— adjustableYes
— presetZ 0 to Z 7
Counting range
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 timer
Number512
Retentivity
— adjustableYes
— presetNo retentivity
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.256 kbyte
Flag
Size, max.4 096 byte
Retentivity availableYes; From MB 0 to MB 4 095
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Data blocks
Retentivity adjustableYes; via non-retain property on DB
Retentivity presetYes
Local data
per priority class, max.32 768 byte; Max. 2048 bytes per block
I/O address area
Inputs8 192 byte
Outputs8 192 byte
of which distributed
— Inputs8 192 byte
— Outputs8 192 byte
Process image
Inputs8 192 byte
Outputs8 192 byte
Inputs, adjustable8 192 byte
Outputs, adjustable8 192 byte
Inputs, default1 024 byte
Outputs, default1 024 byte
Subprocess images
Number of subprocess images, max.1
Digital channels
Inputs65 536
— of which central1 024
Outputs65 536
— of which central1 024
Analog channels
Inputs4 096
— of which central256
Outputs4 096
— of which central256
Hardware configuration
Number of expansion units, max.3
Number of DP masters
integrated2
via CP4
Number of operable FMs and CPs (recommended)
FM8
CP, PtP8
CP, LAN10
Rack
Racks, max.4
Modules per rack, max.8
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Backup time6 wk; At 40 °C ambient temperature
Deviation per day, max.10 s; Typ.: 2 s
Behavior of the clock following POWER-ONClock continues running after POWER OFF
Behavior of the clock following expiry of backup periodthe clock continues at the time of day it had when power was switched off
Operating hours counter
Number4
Number/Number range0 to 3
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 h
retentiveYes; Must be restarted at each restart
Clock synchronization
supportedYes
to MPI, masterYes
on MPI, deviceYes
to DP, masterYes; With DP slave only slave clock
on DP, deviceYes
in AS, masterYes
in AS, deviceYes
on Ethernet via NTPNo
Digital inputs
Number of digital inputs0
Digital outputs
Number of digital outputs0
Analog inputs
Number of analog inputs0
Interfaces
Number of PROFINET interfaces0
Number of RS 485 interfaces2
Number of RS 422 interfaces0
1. Interface
Interface typeIntegrated RS 485 interface
IsolatedYes
Interface types
RS 485Yes
Output current of the interface, max.200 mA
Protocols
MPIYes
PROFIBUS DP masterYes
PROFIBUS DP deviceYes
Point-to-point connectionNo
MPI
Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes; Only server, configured on one side
— S7 communication, as clientNo; but via CP and loadable FB
— S7 communication, as serverYes
PROFIBUS DP master
Transmission rate, max.12 Mbit/s
max. number of DP devices124
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationYes; I blocks only
— S7 communicationYes; Only server, configured on one side
— S7 communication, as clientNo
— S7 communication, as serverYes
— EquidistanceYes
— Isochronous modeNo
— SYNC/FREEZEYes
— activation/deactivation of DP devicesYes
— max. number of DP devices that can be activated/deactivated at the same time8
— Direct data exchange (slave-to-slave communication)Yes; as subscriber
— DPV1Yes
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
User data per DP device
— Inputs, max.244 byte
— Outputs, max.244 byte
PROFIBUS DP device
Transmission rate, max.12 Mbit/s
automatic baud rate searchYes; only with passive interface
Address area, max.32
User data per address area, max.32 byte
Services
— PG/OP communicationYes
— RoutingYes; Only with active interface
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes; Only server, configured on one side
— S7 communication, as clientNo
— S7 communication, as serverYes; Connection configured on one side only
— Direct data exchange (slave-to-slave communication)Yes
— DPV1No
Transfer memory
— Inputs244 byte
— Outputs244 byte
2. Interface
Interface typeIntegrated RS 485 interface
IsolatedYes
Interface types
RS 485Yes
Output current of the interface, max.200 mA
Protocols
MPINo
PROFIBUS DP masterYes
PROFIBUS DP deviceYes
Point-to-point connectionNo
PROFIBUS DP master
Transmission rate, max.12 Mbit/s
max. number of DP devices124
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationYes; I blocks only
— S7 communicationYes; Only server, configured on one side
— S7 communication, as clientNo; but via CP and loadable FB
— S7 communication, as serverYes
— EquidistanceYes
— Isochronous modeYes; OB 61
— SYNC/FREEZEYes
— activation/deactivation of DP devicesYes
— max. number of DP devices that can be activated/deactivated at the same time8
— Direct data exchange (slave-to-slave communication)Yes; as subscriber
— DPV1Yes
Address area
— Inputs, max.8 192 byte
— Outputs, max.8 192 byte
User data per DP device
— Inputs, max.244 byte
— Outputs, max.244 byte
PROFIBUS DP device
Transmission rate, max.12 Mbit/s
automatic baud rate searchYes; only with passive interface
Address area, max.32
User data per address area, max.32 byte
Services
— PG/OP communicationYes
— RoutingYes; Only with active interface
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes; Only server, configured on one side
— S7 communication, as clientNo; but via CP and loadable FB
— S7 communication, as serverYes
— Direct data exchange (slave-to-slave communication)Yes
— DPV1No
Transfer memory
— Inputs244 byte
— Outputs244 byte
Protocols
PROFIsafeNo
Communication functions
PG/OP communicationYes
Data record routingYes
Global data communication
supportedYes
Number of GD loops, max.8
Number of GD packets, max.8
Number of GD packets, transmitter, max.8
Number of GD packets, receiver, max.8
Size of GD packets, max.22 byte
Size of GD packet (of which consistent), max.22 byte
S7 basic communication
supportedYes
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
supportedYes
as serverYes
as clientYes; Via CP and loadable FB
User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication
supportedYes; via CP and loadable FC
Number of connections
overall32
usable for PG communication31
— reserved for PG communication1
— adjustable for PG communication, min.1
— adjustable for PG communication, max.31
usable for OP communication31
— reserved for OP communication1
— adjustable for OP communication, min.1
— adjustable for OP communication, max.31
usable for S7 basic communication30
— reserved for S7 basic communication0
— adjustable for S7 basic communication, min.0
— adjustable for S7 basic communication, max.30
usable for routingX1 as a MPI, max. 10; X1 as DP Master max. 24; X1 as DP Slave (active) max. 14; X2 as DP Master max. 24; X2 as DP Slave (active) max. 14
S7 message functions
Number of login stations for message functions, max.32; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm_S blocks, max.300
Test commissioning functions
Status blockYes; Up to 2 simultaneously
Single stepYes
Number of breakpoints4
Status/control
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.30
— of which status variables, max.30
— of which control variables, max.14
Forcing
ForcingYes
Forcing, variablesInputs, outputs
Number of variables, max.10
Diagnostic buffer
presentYes
Number of entries, max.500
— can be setNo
— of which powerfail-proof100; Only the last 100 entries are retained
Number of entries readable in RUN, max.499
— can be setYes; From 10 to 499
— preset10
Service data
Can be read outYes
Standards, approvals, certificates
CE markYes
UL approvalYes
KC approvalYes
EAC (formerly Gost-R)Yes
Use in hazardous areas
ATEX markingYes
Ambient temperature during operation
min.-25 °C; = Tmin
max.60 °C; = Tmax
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.2 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Configuration software
STEP 7Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203
STEP 7 LiteNo
Programming
Command setsee instruction list
Nesting levels8
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Know-how protection
User program protection/password protectionYes
Block encryptionYes; With S7 block Privacy
Dimensions
Width40 mm
Height125 mm
Depth130 mm
Weights
Weight, approx.360 g

Related Products

1FY2901-0EB00
Siemens 1FY2901-0EB00
View Details

Siemens

1FY2901-0EB00

MFR #1FY2901-0EB00

SKU #YLSJVRF7YVE9X

1FN3050-8SA00-0AA0
View Details

Siemens

1FN3050-8SA00-0AA0

MFR #1FN3050-8SA00-0AA0

SKU #YLSPEYTCHSLPEPH

1FN3100-8SA00-0AA0
View Details

Siemens

1FN3100-8SA00-0AA0

MFR #1FN3100-8SA00-0AA0

SKU #YLSJZNRPZ4VXXL

1FN3150-8SA00-0AA0
View Details

Siemens

1FN3150-8SA00-0AA0

MFR #1FN3150-8SA00-0AA0

SKU #YLSZOWEGFUAGXOH

1FN3300-8SA00-0AA0
View Details

Siemens

1FN3300-8SA00-0AA0

MFR #1FN3300-8SA00-0AA0

SKU #YLSZMAEBPCROKIZ

1FN3450-8SA00-0AA0
View Details

Siemens

1FN3450-8SA00-0AA0

MFR #1FN3450-8SA00-0AA0

SKU #YLSNONBMS6EF28

1FN3600-8SA00-0AA0
View Details

Siemens

1FN3600-8SA00-0AA0

MFR #1FN3600-8SA00-0AA0

SKU #YLS8CPR47M6DMNJ

1FN3900-8SA00-0AA0
View Details

Siemens

1FN3900-8SA00-0AA0

MFR #1FN3900-8SA00-0AA0

SKU #YLSQEN1CGSWWALU

1FY2105-0AA00
View Details

Siemens

1FY2105-0AA00

MFR #1FY2105-0AA00

SKU #YLSGTZWOTRQID

1FY2105-4AA00
View Details

Siemens

1FY2105-4AA00

MFR #1FY2105-4AA00

SKU #YLSDLAYIMNHTZJE

Featured Products

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

MTS32-150M
SMC MTS32-150M
View Details

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
View Details

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

MXS-AS16L
SMC MXS-AS16L
View Details

SMC

MXS-AS16L

MFR #MXS-AS16L

SKU #YLSAP0XXFGFSWY6

MY1M20-200AH
SMC MY1M20-200AH
View Details

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
View Details

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

Related Searches

Siemens 6AG1317-6FF04-2AB0 priceSiemens 6AG1317-6FF04-2AB0 quotebuy Siemens 6AG1317-6FF04-2AB06AG1317-6FF04-2AB0 price6AG1317-6FF04-2AB0 stock availabilitySiemens spare partsSiemens 6AG1317-6FF04-2AB0 equivalentSiemens 6AG1317-6FF04-2AB0 specifications