Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 6AG1214-1BH50-7XB0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 6AG1214-1BH50-7XB0

SIPLUS S7-1200 G2: CPU 1214C AC/DC/RLY based on 6ES7214-1BH50-0XB0 with conformal coating -40...+70 °C . power supply: AC 85-264 V AC at 47-63 Hz; onboard I/O: 14x DI 24 V DC; 10 DO relay 2 A; memory: program 250 KB data: 750 KB, retentivity: 20 KB

SiemensMFR # 6AG1214-1BH50-7XB0SKU # YLSROTRPA4GQMYB
Product type designationCPU 1214C AC/DC/Relay
FW update possibleYes
based on6ES7214-1BH50-0XB0
I&M dataYes; I&M0 to I&M3
SysLogYes
120 V ACYes
Share

About This Product

SIPLUS S7-1200 G2: CPU 1214C AC/DC/RLY based on 6ES7214-1BH50-0XB0 with conformal coating -40...+70 °C . power supply: AC 85-264 V AC at 47-63 Hz; onboard I/O: 14x DI 24 V DC; 10 DO relay 2 A; memory: program 250 KB data: 750 KB, retentivity: 20 KB

Siemens 6AG1214-1BH50-7XB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationCPU 1214C AC/DC/Relay
FW update possibleYes
based on6ES7214-1BH50-0XB0
Product function
I&M dataYes; I&M0 to I&M3
SysLogYes
Supply voltage
120 V ACYes
230 V ACYes
permissible range, lower limit (AC)85 V
permissible range, upper limit (AC)264 V
Line frequency
permissible range, lower limit47 Hz
permissible range, upper limit63 Hz
Input current
Current consumption (rated value)80 mA at 120 V AC; 44 mA at 240 V AC
Current consumption, max.480 mA at 120 V AC; 275 mA at 240 V AC
Inrush current, max.20 A; at 264 V
I²t0.8 A²·s
Output current
for backplane bus (5 V DC), max.1 600 mA; Max. 5 V DC for SM and CM
24 V encoder supply
24 VYes; 20.4 to 28.8V
Short-circuit protectionYes
Output current, max.400 mA
Power loss
Power loss, typ.4 W
Work memory
integrated1 000 kbyte
integrated (for program)250 kbyte
integrated (for data)750 kbyte
Load memory
Integrated8 Mbyte
Plug-in (SIMATIC Memory Card), max.32 Gbyte; with SIMATIC memory card
Backup
presentYes
maintenance-freeYes
without batteryYes
CPU processing times
for bit operations, typ.37 ns; / instruction
for word operations, typ.30 ns; / instruction
for floating point arithmetic, typ.74 ns; / instruction
CPU-blocks
Number of elements (total)4 000; Blocks (OB, FB, FC, DB) and UDTs
OB
Number of free cycle OBs100
Number of time alarm OBs20
Number of delay alarm OBs20
Number of cyclic interrupt OBs20; with minimum OB 3x cycle of 1 ms
Number of process alarm OBs50
Number of DPV1 alarm OBs3
Number of isochronous mode OBs1
Number of startup OBs100
Number of asynchronous error OBs4
Number of synchronous error OBs2
Number of diagnostic alarm OBs1
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.20 kbyte
Flag
Size, max.8 kbyte; Size of bit memory address area
Local data
per priority class, max.64 kbyte; max. 16 KB per block
Process image
Inputs, adjustable1 kbyte
Outputs, adjustable1 kbyte
Hardware configuration
Number of modules per system, max.10
number of expansion boards (SB, CB, BB)1
number of signal modules (SM)6; depends on the number of CMs
number of communications modules (CM)3
Clock
Hardware clock (real-time)Yes
Backup time480 h; Typical
Deviation per day, max.2 s; at 25 °C
Digital inputs
Number of digital inputs14; Integrated
of which inputs usable for technological functions8; HSC (High Speed Counting)
Sourcing/sinking inputYes
all mounting positions
— up to 40 °C, max.14
Input voltage
Rated value (DC)24 V
for signal "0"5 V DC or 0.5 mA
for signal "1"15 V DC at 2.5 mA
for standard inputs
— parameterizable0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms
— at "0" to "1", min.0.1 µs
— at "0" to "1", max.20 ms
for interrupt inputs
— parameterizableYes
for technological functions
— parameterizablesingle phase: 6 HSCs @ 100 kHz & 2 standard @ 30 kHz, quadrature phase: 6 HSCs @ 80 kHz & 2 standard @ 20 kHz
Cable length
shielded, max.500 m; 50 m for technological functions
unshielded, max.300 m; for technological functions: No
Digital outputs
Number of digital outputs10; Relays
Switching capacity of the outputs
with resistive load, max.2 A
on lamp load, max.30 W with DC, 200 W with AC
Output delay with resistive load
"0" to "1", max.10 ms; max.
"1" to "0", max.10 ms; max.
Switching frequency
of the pulse outputs, with resistive load, max.Not recommended
Relay outputs
Number of relay outputs10
Number of operating cycles, max.mechanically 10 million, at rated load voltage 100 000
Cable length
shielded, max.500 m
unshielded, max.150 m
Analog inputs
Number of analog inputs0
Analog outputs
Number of analog outputs0
Connectable encoders
2-wire sensorYes
Interfaces
Number of PROFINET interfaces1
1. Interface
Interface typePROFINET
IsolatedYes
automatic detection of transmission rateYes
AutonegotiationYes
AutocrossingYes
Interface types
RJ 45 (Ethernet)Yes
Number of ports2
integrated switchYes
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO DeviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyYes
PROFINET IO Controller
Transmission rate, max.100 Mbit/s
Services
— PG/OP communicationYes; encryption with TLS V1.3 pre-selected
— Isochronous modeYes
— IRTYes
— PROFIenergyYes; per user program
— Prioritized startupYes
— Number of IO devices with prioritized startup, max.16
— Number of connectable IO Devices, max.31
— Of which IO devices with IRT, max.31
— Number of connectable IO Devices for RT, max.31
— of which in line, max.31
— Number of IO Devices that can be simultaneously activated/deactivated, max.8
— Updating timeThe minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
Update time for IRT
— for send cycle of 1 ms1 ms to 16 ms
— for send cycle of 2 ms2 ms to 32 ms
— for send cycle of 4 ms4 ms to 64 ms
Update time for RT
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
Services
— PG/OP communicationYes; encryption with TLS V1.3 pre-selected
— Isochronous modeNo
— IRTYes
— PROFIenergyYes; per user program
— Shared deviceYes
— Number of IO Controllers with shared device, max.2
Protocols
Supports protocol for PROFINET IOYes
PROFIsafeNo
PROFIBUSNo
OPC UANo
AS-InterfaceNo
Protocols (Ethernet)
TCP/IPYes
DHCPYes
SNMPYes
DCPYes
LLDPYes
Number of connections
Number of connections, max.128; via integrated interfaces of the CPU and connected CPs / CMs
Number of connections reserved for ES/HMI/web10
Number of connections via integrated interfaces88
Media redundancy
— MRPYes; as MRP redundancy manager and/or MRP client
— MRPDYes
SIMATIC communication
S7 routingNo
S7 communication, as serverYes
S7 communication, as clientYes
Open IE communication
TCP/IPYes
— Data length, max.8 kbyte
— several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes
— Data length, max.8 kbyte
UDPYes
— Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
DHCPYes
DNSYes
SNMPYes
DCPYes
LLDPYes
EncryptionYes; Optional
Web server
supportedYes
HTTPSYes
web APIYes
— Number of sessions, max.30
User-defined websitesYes
Further protocols
MODBUSYes
S7 communication
supportedYes
as serverYes
as clientYes
User data per job, max.See online help (S7 communication, user data size)
Number of connections
overallPG Connections: 4 reserved; HMI Connections: 4 reserved / 82 max; S7 Connections: 78 max; Open User Connections: 78 max; Web Connections: 2 reserved / 80 max; Total Connections: 10 reserved / 88 max
S7 message functions
Number of login stations for message functions, max.32
Program alarmsYes
Number of configurable program messages, max.5 000
Number of loadable program messages in RUN, max.2 500
Number of program alarms600
Number of alarms for system diagnostics100
Number of alarms for motion technology objects160
Status/control
Status/control variableYes
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Forcing
ForcingYes
Diagnostic buffer
presentYes
Traces
Number of configurable Traces4
Memory size per trace, max.512 kbyte
Diagnostics indication LED
RUN/STOP LEDYes
ERROR LEDYes
MAINT LEDYes
Supported technology objects
Motion ControlYes
Number of available Motion Control resources for technology objects800
— per speed-controlled axis40
— per positioning axis80
— per synchronous axis160
— per external encoder80
— per output cam20
— per cam track160
— per probe40
Number of available Extended Motion Control resources for technology objects40
— per cam (1 000 points and 50 segments)2; 1000 points and 1 segment
— for each set of kinematics30
— kinematics with up to 4 interpolating axesYes
— kinematics with 5 or more interpolating axesNo
— user-defined kinematicsNo
— SIMATIC Safe KinematicsNo
— Number of positioning axes at motion control cycle of 4 ms (typical value)10
— Number of positioning axes at motion control cycle of 8 ms (typical value)10
Integrated Functions
CounterYes
Number of counters8
Counting frequency, max.100 kHz; Ia.0 to Ia.5: 100 kHz (80 kHz in quadrature mode), Ia.6 to Ib.5: 30 kHz (20 kHz in quadrature mode)
Frequency measurementYes
PID controllerYes
Number of pulse outputs8; individually assigned to CPU and Signal Board
Limit frequency (pulse)100 kHz
Potential separation digital inputs
Potential separation digital inputsYes; field side to logic: 707 V DC (type test)
between the channelsNo
Number of potential groups1
Potential separation digital outputs
Potential separation digital outputsRelays
between the channelsNo
Number of potential groups1
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2Yes
— Test voltage at air discharge8 kV
— Test voltage at contact discharge6 kV
Interference immunity to cable-borne interference
Interference immunity on supply lines acc. to IEC 61000-4-4Yes
Interference immunity on signal cables acc. to IEC 61000-4-4Yes
Interference immunity against voltage surge
Interference immunity on supply lines acc. to IEC 61000-4-5Yes
Interference immunity against conducted variable disturbance induced by high-frequency fields
Interference immunity against high-frequency radiation acc. to IEC 61000-4-6Yes
Emission of radio interference acc. to EN 55 011
Limit class A, for use in industrial areasYes; Group 1
Limit class B, for use in residential areasYes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011
Degree and class of protection
IP degree of protectionIP20
Standards, approvals, certificates
Siemens Eco Profile (SEP)Siemens EcoTech
Ecological footprint
environmental product declarationYes; type 2 acc. to ISO 14021
Global warming potential
— global warming potential, (total) [CO2 eq]68 kg
— global warming potential, (during production) [CO2 eq]14.4 kg
— global warming potential, (during operation) [CO2 eq]54.2 kg
— global warming potential, (after end of life cycle) [CO2 eq]-0.723 kg
Security
signed firmware updateYes
Secure BootYes
securely removing dataNo
Free fall
Fall height, max.0.3 m; five times, in product package
Ambient temperature during operation
min.-40 °C
max.40 °C; 40 °C horizontal or 30 °C vertical at max. voltages and max. specifications
horizontal installation, min.-40 °C; incl. condensation/frost
horizontal installation, max.70 °C; at rated voltages, 50 % of max. specification and alternate IO active
vertical installation, min.-40 °C
vertical installation, max.50 °C; at rated voltages, 50 % of max. specification and alternate IO active
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Air pressure acc. to IEC 60068-2-13
Operation, min.540 hPa
Operation, max.1 140 hPa
Storage/transport, min.540 hPa
Storage/transport, max.1 140 hPa
Altitude during operation relating to sea level
Installation altitude, min.-1 000 m
Installation altitude, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Vibrations
Vibration resistance during operation acc. to IEC 60068-2-63.5 mm from 5 - 8.4 Hz, 1g from 8.4 - 150 Hz
Operation, tested according to IEC 60068-2-6Yes
Shock testing
tested according to IEC 60068-2-27Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna)
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Programming language
— LADYes
— FBDYes
— SCLYes
Know-how protection
User program protection/password protectionYes
Access protection
protection of confidential configuration dataYes
Protection level: Write protectionYes
Protection level: Read/write protectionYes
Protection level: Complete protectionYes
User administrationYes; device-wide
Number of users100
Number of groups100
Number of roles50
Cycle time monitoring
can be setYes
Dimensions
Width80 mm
Height125 mm
Depth100 mm
Weights
Weight, approx.417 g

Accessories 1

Genuine accessories that can be used with the Siemens 6AG1214-1BH50-7XB0 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
9TF6276-2XA11-1AL4Servis

Related Products

1FY2901-0EB00
Siemens 1FY2901-0EB00
View Details

Siemens

1FY2901-0EB00

MFR #1FY2901-0EB00

SKU #YLSJVRF7YVE9X

1FN3050-8SA00-0AA0
View Details

Siemens

1FN3050-8SA00-0AA0

MFR #1FN3050-8SA00-0AA0

SKU #YLSPEYTCHSLPEPH

1FN3100-8SA00-0AA0
View Details

Siemens

1FN3100-8SA00-0AA0

MFR #1FN3100-8SA00-0AA0

SKU #YLSJZNRPZ4VXXL

1FN3150-8SA00-0AA0
View Details

Siemens

1FN3150-8SA00-0AA0

MFR #1FN3150-8SA00-0AA0

SKU #YLSZOWEGFUAGXOH

1FN3300-8SA00-0AA0
View Details

Siemens

1FN3300-8SA00-0AA0

MFR #1FN3300-8SA00-0AA0

SKU #YLSZMAEBPCROKIZ

1FN3450-8SA00-0AA0
View Details

Siemens

1FN3450-8SA00-0AA0

MFR #1FN3450-8SA00-0AA0

SKU #YLSNONBMS6EF28

1FN3600-8SA00-0AA0
View Details

Siemens

1FN3600-8SA00-0AA0

MFR #1FN3600-8SA00-0AA0

SKU #YLS8CPR47M6DMNJ

1FN3900-8SA00-0AA0
View Details

Siemens

1FN3900-8SA00-0AA0

MFR #1FN3900-8SA00-0AA0

SKU #YLSQEN1CGSWWALU

1FY2105-0AA00
View Details

Siemens

1FY2105-0AA00

MFR #1FY2105-0AA00

SKU #YLSGTZWOTRQID

1FY2105-4AA00
View Details

Siemens

1FY2105-4AA00

MFR #1FY2105-4AA00

SKU #YLSDLAYIMNHTZJE

Featured Products

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
View Details

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
View Details

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

MTS32-150M
SMC MTS32-150M
View Details

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

MY1M20-200AH
SMC MY1M20-200AH
View Details

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

Related Searches

Siemens 6AG1214-1BH50-7XB0 priceSiemens 6AG1214-1BH50-7XB0 quotebuy Siemens 6AG1214-1BH50-7XB06AG1214-1BH50-7XB0 price6AG1214-1BH50-7XB0 stock availabilitySiemens spare partsSiemens 6AG1214-1BH50-7XB0 equivalentSiemens 6AG1214-1BH50-7XB0 specifications