product type designation
product brand nameSIPLUS
product type designationX202-2P IRT
transfer rate
transfer rate10, 100 Mbit/s
interfaces / for communication / integrated
for network components or terminal equipment2
number of 100 Mbit/s SC-RJ-ports / for POF FOC / with push-pull connection system2
interfaces / other
for signaling contact1
for power supply1
for signaling contact2-pole terminal block
for power supply4-pole terminal block
C-PLUGYes
at DC / rated value24 V
at DC / maximum0.1 A
supply voltage, current consumption, power loss
type of voltage / 1 / of the supply voltageDC
supply voltage / 1 / rated value24 V
power loss [W] / 1 / rated value4.8 W
supply voltage / 1 / voltage range18 ... 32
consumed current / 1 / maximum0.2 A
product component / 1 / fusing at power supply inputYes
fuse protection type / 1 / at input for supply voltage2.5 A (cannot be replaced by user)
ambient conditions
ambient temperature / in horizontal mounting position / during operation-40 ... +60 °C
installation altitude / at height above sea level / maximum5000 m
with condensation / according to IEC 60068-2-38 / maximum100 %; RH including condensation/frost (no commissioning when condensation is present), horizontal installation
chemical resistance / to commercially available cooling lubricantsYes; incl. airborne diesel and oil droplets
ambient condition / relating to ambient temperature - air pressure - installation altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
conformity according to EN 60721-3-3Yes; Class 3B2 mold and fungal spores (excluding fauna); class 3B3 on request
conformity according to EN 60721-3-6Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna)
conformity according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
conformity according to EN 60721-3-6Yes; Class 6C3 (RH < 75%) incl. salt spray acc. to EN 60068-2-52 (Severity degree 3); *
conformity according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust; *
conformity according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
environmental category / according to IEC 60721 / note* The supplied plug covers must remain in place on the unused interfaces during operation!
coating / for equipped printed circuit board / according to EN 61086Yes; Class 2 for high availability
type of coating / protection against pollution according to EN 60664-3Yes; protection of the type 1
type of test / of the coating / according to MIL-I-46058CYes; coating discoloration during service life possible
product conformity / of the coating / Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; conformal coating, class A
protection class IPIP30
design, dimensions and weights
designcompact
width60 mm
height125 mm
depth124 mm
net weight0.78 kg
35 mm top hat DIN rail mountingYes
wall mountingYes
S7-300 rail mountingYes
S7-1500 rail mountingNo
product features, product functions, product components / general
cascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s50
cascading in cases of star topologyany (depending only on signal propagation time)
product functions / management, configuration, engineering
CLIYes
web-based managementYes
MIB supportYes
TRAPs via emailYes
configuration with STEP 7Yes
port mirroringNo
multiport mirroringNo
with IRT / PROFINET IO switchYes
PROFINET IO diagnosisYes
switch-managedYes
PROFINET conformity classC
network load class / according to PROFINETII
TelnetYes
HTTPYes
HTTPSYes
TFTPYes
FTPYes
BOOTPNo
DCPYes
LLDPYes
SNMP v1Yes
SNMP v2Yes
SNMP v3Yes
I&M0 - device-specific informationYes
I&M1 - higher level designation/location designationYes
product functions / diagnostics
port diagnosticsYes
statistics Packet SizeYes
statistics packet typeYes
error statisticsYes
product functions / DHCP
DHCP clientYes
product functions / redundancy
protocol / is supported / Media Redundancy Protocol (MRP)Yes
media redundancy protocol (MRP) with redundancy managerYes
Media Redundancy Protocol for Planned Duplication (MRPD)Yes
ring redundancyYes
high speed redundancy protocol (HRP) with redundancy managerYes
high speed redundancy protocol (HRP) with standby redundancyYes
Parallel Redundancy Protocol (PRP)/operation in the PRP-networkYes
Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)No
passive listeningYes
product functions / security
SSHYes
product functions / time
SICLOCK supportYes
NTPNo
SNTPYes
standards, specifications, approvals
CE markingYes
KC approvalYes
Regulatory Compliance Mark (RCM)Yes
for EMC interference emissionEN 61000-6-4:2001 (Class A)
for immunity to EMCEN 61000-6-4:2001
for safety / from CSA and ULUL 60950-1, CSA C22.2 No. 60950-1
standards, specifications, approvals / hazardous environments
ATEXYes
UKEXYes
IECExYes
CCC / for hazardous zone according to GB standardYes
FM registrationYes
standards, specifications, approvals / other
railway application in accordance with EN 50155No
railway application in accordance with EN 50124-1No
RoHS conformityYes
resistance to air pollution / conformity according to ANSI/ISA-71.04Yes; G3
standards, specifications, approvals / Environmental Product Declaration
Environmental Product DeclarationYes
total179.66 kg
during manufacturing29.12 kg
during operation150.31 kg
after end of life0.23 kg
product functions / general
MTBF83.72 a
warranty period5 a
product function / is supported / identification linkYes; acc. to IEC 61406-1:2022
Approvals / Certificates
global warming potential [CO2 eq] / during manufacturing29.12 kg
global warming potential [CO2 eq] / during operation150.31 kg
global warming potential [CO2 eq] / after end of life0.23 kg
global warming potential [CO2 eq] / total179.66 kg