General information
Product type designationF-RQ 1x24 V DC/24 ... 230 V AC/5 A
based on6ES7136-6RA00-0BF0
usable BaseUnitsBU type F0
Color code for module-specific color-coded labelCC42
Product function
I&M dataYes; I&M0 to I&M3
Engineering with
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
power supply according to NEC Class 2 requiredNo
Power
Power consumption from the backplane bus100 mW
Power loss
Power loss, typ.1 W
Address space per module
Inputs1 byte
Hardware configuration
Automatic encodingYes
Mechanical coding elementYes
Type of mechanical coding elementtype C
Digital outputs
Type of digital outputRelays
Number of digital outputs1
Limitation of inductive shutdown voltage toNo
Controlling a digital inputYes
Switching capacity of the outputs
with resistive load, max.5 A
on lamp load, max.25 W
Switching frequency
with resistive load, max.2 Hz
with inductive load, max.0.1 Hz; See data in manual
with inductive load (acc. to IEC 60947-5-1, DC13), max.0.1 Hz
with inductive load (acc. to IEC 60947-5-1, AC15), max.2 Hz
horizontal installation
— up to 40 °C, max.5 A; note derating data in the manual
— up to 50 °C, max.4 A; note derating data in the manual
— up to 60 °C, max.3 A; note derating data in the manual
— up to 70 °C, max.3 A; note derating information in the manual; only with configured slots to the left and right of the module
vertical installation
— up to 50 °C, max.3 A; note derating data in the manual
Relay outputs
Number of relay outputs1; 2 NO contacts
Rated supply voltage of relay coil L+ (DC)24 V
Current consumption of relays (coil current of all relays), max.70 mA
external protection for relay outputsyes; 6 A, see data in manual
Relay approved acc. to UL 508Yes; Pilot Duty B300, R300
Switching capacity of contacts
— with inductive load, max.see additional description in the manual
— with resistive load, max.see additional description in the manual
— Thermal continuous current, max.5 A
— Switching current, min.1 mA
— Switching current after exceeding 300 mA, min.10 mA
— Switching current after exceeding 300 mA, max.5 A
— Rated switching voltage (DC)24 V
— Rated switching voltage (AC)230 V
Cable length
shielded, max.500 m; for load contacts
unshielded, max.300 m; for load contacts
Control cable (input), max.10 m
Interrupts/diagnostics/status information
Diagnostics functionYes
Diagnostics indication LED
RUN LEDYes; green/red DIAG LED
Channel status displayYes; green LED
Potential separation channels
between the channelsYes; for SELV / PELV only
between the channels and backplane busYes
between the channels and the power supply of the electronicsYes
Permissible potential difference
between channels and backplane bus/supply voltage250 V AC (reinforced insulation)
Isolation
Isolation tested with2 545 V DC/2 s (routine test)
Overvoltage categoryIII (according to IEC/EN 61131-2:2007 and EN 298:2022), II (according to IEC 61131-2:2017 and IEC 61010-2-201)
Standards, approvals, certificates
Suitable for safety functionsYes
Ecological footprint
environmental product declarationYes
Global warming potential
— global warming potential, (total) [CO2 eq]52 kg
— global warming potential, (during production) [CO2 eq]6.8 kg
— global warming potential, (during operation) [CO2 eq]45.8 kg
— global warming potential, (after end of life cycle) [CO2 eq]-0.628 kg
Highest safety class achievable in safety mode
Performance level according to ISO 13849-1PLe
Category according to ISO 13849-14
SIL acc. to IEC 61508SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
— Low demand mode: PFDavg in accordance with SIL2< 1.00E-04, function test 1x per year
— Low demand mode: PFDavg in accordance with SIL3< 1.00E-05, function test 1x per month
— High demand/continuous mode: PFH in accordance with SIL2< 1.00E-08 1/h, function test 1x per year
— High demand/continuous mode: PFH in accordance with SIL3< 6.00E-09 1/h, function test 1x per month
Ambient temperature during operation
horizontal installation, min.-30 °C; = Tmin (incl. condensation/frost)
horizontal installation, max.60 °C; = Tmax; +70 °C with spacing modules (6AG1193-6BN00-7BA0) or configured slots to the left and right of the module
vertical installation, min.-30 °C; = Tmin
vertical installation, max.50 °C; = Tmax
Altitude during operation relating to sea level
Installation altitude above sea level, max.2 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna)
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Dimensions
Width20 mm
Height73 mm
Depth58 mm
Weights
Weight, approx.90 g