General information
Product type designationF-TM Count 1x1Vpp sin/cos HF
FW update possibleYes
based on6ES7136-6CB00-0CA0
usable BaseUnitsBU type A0
Color code for module-specific color-coded labelCC01
Product function
I&M dataYes; I&M0 to I&M3
Engineering with
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Supply voltage
Rated value (DC)24 V
power supply according to NEC Class 2 requiredNo
Load voltage L+
Rated value (DC)24 V
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Input current
Current consumption, max.50 mA; without load, 150 mA with 300 mA encoder load
5 V encoder supply
5 VYes; 5.1 V ±3.5 %
Short-circuit protectionYes; Electronic overload protection; no protection on applying a normal or counter voltage.
Output current, max.300 mA
Power loss
Power loss, typ.1.25 W
Address space per module
Inputs14 byte; S7-300/400F CPU, 13 byte
Outputs5 byte; S7-300/400F CPU, 4 byte
Hardware configuration
Automatic encodingYes
Electronic coding element type HYes
Digital inputs
Number of digital inputs1; (counter input)
Digital inputs, parameterizableYes
Digital input functions, parameterizable
Gate start/stopYes
Counter for incremental encoderYes
— Number, max.1
Input voltage
Type of input voltagesin/cos 1 Vpp
Input delay (for rated value of input voltage)
Minimum pulse width for program reactions2.5 µs
for technological functions
— ParameterizableYes
Cable length
shielded, max.150 m
Connectable encoders
Incremental encoder (symmetrical)Yes; up to 200 kHz depending on cable type and length
Encoder signals, incremental encoder (symmetrical)
Input voltage1 Vpp, centered at 2.5 V offset
Input frequency, max.200 kHz
Counting frequency, max.800 kHz; with quadruple evaluation
Cable length, shielded, max.150 m
Incremental encoder with A/B tracks, 90° phase offsetYes; sin/cos
Incremental encoder with A/B tracks, 90° phase offset and zero trackYes; sin/cos/zero
Interfaces
Number of RS 485 interfaces0
Interrupts/diagnostics/status information
Diagnostics functionYes; see chapter "Diagnostic Messages" in the manual
Alarms
Diagnostic alarmYes
Hardware interruptNo
Diagnoses
Monitoring the supply voltageYes
Wire breakYes
short-circuitYes
A/B transition error at incremental encoderYes
Diagnostics indication LED
RUN LEDYes; green LED
ERROR LEDYes; red LED
Monitoring of the supply voltage (PWR-LED)Yes; green LED
Channel status displayYes; green LED
for channel diagnosticsYes; red LED
for module diagnosticsYes; green/red DIAG LED
Integrated Functions
CounterYes
Number of counters1
Counting frequency, max.800 kHz; with quadruple evaluation
Safety monitoring functions
Safe Operating Stop (SOS)Yes
Safely-Limited Speed (SLS)Yes
Safe Direction (SDI)Yes
Safe Speed Monitor (SSM)Yes
Counting functions
Continuous countingYes
Counter response parameterizableYes
Software gateYes
Counting range, parameterizableYes
Measuring range
— Frequency measurement, min.0.04 Hz
— Frequency measurement, max.800 kHz; with quadruple evaluation
— Cycle duration measurement, min.1 µs
— Cycle duration measurement, max.25 s
— Velocity measurement, min.0 (speed in configured units per selected time basis - speed*1 000)
— Velocity measurement, max.2 147 483 (speed in configured units per selected time basis - speed*1 000)
Accuracy
— Frequency measurementup to 100 ppm; depending on measuring interval and signal evaluation; at low frequency external noise may have an effect on accuracy (reference the graph in 2.2.3)
— Cycle duration measurementup to 100 ppm; depending on measuring interval and signal evaluation; at low frequency external noise may have an effect on accuracy (reference the graph in 2.2.3)
— Velocity measurementup to 100 ppm; depending on measuring interval and signal evaluation; at low frequency external noise may have an effect on accuracy (reference the graph in 2.2.3)
Potential separation channels
between the channelsNo; Only one channel is available
between the channels and backplane busYes
Between the channels and load voltage L+No
between the channels and the power supply of the electronicsNo
Isolation
Isolation tested with707 V DC (type test)
Standards, approvals, certificates
Suitable for safety functionsYes
Ecological footprint
environmental product declarationYes
Global warming potential
— global warming potential, (total) [CO2 eq]88.3 kg
— global warming potential, (during production) [CO2 eq]13.1 kg
— global warming potential, (during operation) [CO2 eq]76.6 kg
— global warming potential, (after end of life cycle) [CO2 eq]-1.37 kg
Highest safety class achievable in safety mode
Performance level according to ISO 13849-1Cat. 4, PLe
SIL acc. to IEC 61508SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
— low demand mode: PFDavg in accordance with SIL1< 2.00E-03 signal monitoring disabled
— Low demand mode: PFDavg in accordance with SIL3< 3.00E-05
— high demand/continuous mode: PFH in accordance with SIL1< 3.00E-08 1/h signal monitoring disabled
— High demand/continuous mode: PFH in accordance with SIL3< 1.00E-09 1/h
Ambient temperature during operation
horizontal installation, min.-25 °C; = Tmin (incl. condensation/frost)
horizontal installation, max.60 °C; = Tmax; +70 °C with spacing modules (6AG1193-6BN00-7BA0) or configured slots to the left and right of the module
vertical installation, min.-25 °C; = Tmin
vertical installation, max.55 °C; = Tmax
Altitude during operation relating to sea level
Installation altitude above sea level, max.2 000 m
Ambient air temperature-barometric pressure-altitudeOn request: Installation altitudes greater than 2 000 m
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
— Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0//6AG1193-6AB00-0AA0)
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna)
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-6Yes; class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Dimensions
Width15 mm
Height73 mm
Depth58 mm
Weights
Weight, approx.42 g