General information
Product type designationRQ 4x120 VDC ... 230 VAC/5 A NO ST
FW update possibleNo
based on6ES7132-6HD01-0BB1
usable BaseUnitsBU type B0, B1
Product function
I&M dataYes; I&M0 to I&M3
Isochronous modeNo
Engineering with
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Operating mode
DQYes
DQ with energy-saving functionNo
PWMNo
OversamplingNo
MSONo
Redundancy
Redundancy capabilityYes
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Input current
Current consumption (rated value)55 mA; without load
Output voltage
Rated value (AC)230 V
Power loss
Power loss, typ.1.5 W
Address space per module
Inputs+ 1 byte for QI information
Outputs1 byte
Hardware configuration
Automatic encodingYes
Mechanical coding elementYes
Type of mechanical coding elementtype C
Selection of BaseUnit for connection variants
2-wire connectionBU type B1
3-wire connectionBU type B0
Digital outputs
Type of digital outputRelays
Number of digital outputs4
Current-sinkingYes
Current-sourcingYes
Digital outputs, parameterizableYes
Short-circuit protectionNo
Parallel switching of two outputs
for logic linksYes
for upratingNo
for redundant control of a loadYes
Switching frequency
with resistive load, max.2 Hz
with inductive load (acc. to IEC 60947-5-1, DC13), max.0.5 Hz; provide one freewheeling diode for switching frequencies higher than 0.1 Hz
with inductive load (acc. to IEC 60947-5-1, AC15), max.0.5 Hz
on lamp load, max.2 Hz
Total current of the outputs
Current per channel, max.5 A; > +60 °C max. continuous current per relay 3 A
Current per module, max.20 A
horizontal installation
— up to 50 °C, max.20 A
— up to 60 °C, max.16 A
vertical installation
— up to 40 °C, max.20 A
— up to 50 °C, max.16 A; in all other mounting positions
Relay outputs
Number of relay outputs4
Rated supply voltage of relay coil L+ (DC)24 V
Current consumption of relays (coil current of all relays), max.40 mA
external protection for relay outputsYes, with miniature fuse max. 6 A tripping current and quick-response tripping characteristic
Number of operating cycles, max.7 000 000; see additional description in the manual
Switching capacity of contacts
— with inductive load, max.2 A; see additional description in the manual
— with resistive load, max.5 A; see additional description in the manual
— Thermal continuous current, max.5 A; Max. 1 385 VA, 150 W
— Switching current, min.100 mA; 5 V DC
— Rated switching voltage (DC)24 V DC to 120 V DC
— Rated switching voltage (AC)24V AC to 230V AC
Cable length
shielded, max.1 000 m
unshielded, max.200 m
Interrupts/diagnostics/status information
Diagnostics functionYes
Substitute values connectableYes
Alarms
Diagnostic alarmYes
Diagnoses
Monitoring the supply voltageYes
Wire breakNo
Short-circuitNo
Diagnostics indication LED
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Channel status displayYes; green LED
for channel diagnosticsNo
for module diagnosticsYes; green/red DIAG LED
Potential separation channels
between the channelsYes
between the channels and backplane busYes
between the channels and the power supply of the electronicsYes
Permissible potential difference
between channels and backplane bus/supply voltage240 V AC
Isolation
Isolation tested with2 500 V DC (type test)
tested with
between channels and backplane bus/supply voltage2 500 V DC
between backplane bus and supply voltage707 V DC (type test)
Standards, approvals, certificates
Suitable for safety functionsNo
Ambient temperature during operation
horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
horizontal installation, max.70 °C; = Tmax; see Derating BasedOn (e.g. manual), additionally Tmax > 60 °C max. continuous current of 3 A per relay
vertical installation, min.-40 °C; in all other mounting positions
vertical installation, max.50 °C; in all other mounting positions
Altitude during operation relating to sea level
Installation altitude above sea level, max.3 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 1 K/100 m) at 795 hPa ... 701 hPa (+2 000 m ... +3 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; incl. condensation / frost permitted (no commissioning under condensation conditions)
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
— Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-6Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Dimensions
Width20 mm
Height73 mm
Depth58 mm
Weights
Weight, approx.40 g