Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 5WG1501-1AB01

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 5WG1501-1AB01

N 501/01 - KNX Combination blind actuator, 4 x AC 230 V, 6 A, 8 x binary inputs. 8 inputs for DC or AC in the range from 12 to 230 V 8 relay contact outputs locked in pairs against each other for controlling 4 × AC 230 V sunblind drives Contact rated voltage AC 230 V Contact rated current 6 A, p.f. = 1 Electronics powered by a AC 230 V integrated power supply Device functional even without bus connection or if the bus communication fails Preset on delivery for direct output control for each blind button function via momentary contact switches connected to the inputs Key for switching between bus and direct mode Button for each relay contact output, for switching the output in direct mode Selectable function for each input when using the ETS: Switching status, send binary value Switching on leading edge, switching Short/Long 1-pushbutton dimming, sunblind control, group control 1-bit/8-bit scene control 8-bit/16-bit value leading edge, Short/Long 16-bit floating point value leading edge, Short/Long Or for each pair of inputs: Acting directly on the corresponding outputs as blind button 2-button dimming with stop telegram or with cyclical sending 2-pushbutton sunblind control Selectable blocking of each input via a corresponding blocking object Sending of input objects after change Selectable cyclical input object sending Individual or shared configuration of actuator channels Communication objects for each blind channel for driving the sun protection into the end positions or for stopping the procedure and adjusting the blind slats in steps Communication objects for setting position of slats and blinds in percentage information Automatic opening of the blind slats to a preconfigured nominal setting after uninterrupted driving down of the blind from the top to the bottom end position, with integrated 1-bit scene control for storing and calling up (reproduction) of 2 interim blind and slat settings Integrated 1-bit/8-bit scene control, 8 scenes can be integrated per channel Optional "Sun" object for integration in a sunlight tracking control system Differentiation between automatic and manual mode and with automatic switchover from automatic to manual mode for the channel in question by pressing a bus button for manual control of the corresponding sun protection Manual mode taking precedence over automatic position commands Optional central command for each device or each channel for switching the relevant channels to automatic mode and driving the sun protection into the up or down end position Alarm: move to safety position, Locking in this position for as long as alarm is active Travel lock (e. g. for cleaning the outer shutter/blinds) Status objects for each channel for querying or for automatic sending of sun protection and slat settings as a percentage value Optional status objects for reporting that the up or down position has been reached Integrated bus coupling unit, Bus connection via bus terminal or contact system to data rail Modular installation devices for mounting on TH35 EN 60715 mounting rail

SiemensMFR # 5WG1501-1AB01SKU # CEY-8EF3B03073FD
Share

About This Product

N 501/01 - KNX Combination blind actuator, 4 x AC 230 V, 6 A, 8 x binary inputs. 8 inputs for DC or AC in the range from 12 to 230 V 8 relay contact outputs locked in pairs against each other for controlling 4 × AC 230 V sunblind drives Contact rated voltage AC 230 V Contact rated current 6 A, p.f. = 1 Electronics powered by a AC 230 V integrated power supply Device functional even without bus connection or if the bus communication fails Preset on delivery for direct output control for each blind button function via momentary contact switches connected to the inputs Key for switching between bus and direct mode Button for each relay contact output, for switching the output in direct mode Selectable function for each input when using the ETS: Switching status, send binary value Switching on leading edge, switching Short/Long 1-pushbutton dimming, sunblind control, group control 1-bit/8-bit scene control 8-bit/16-bit value leading edge, Short/Long 16-bit floating point value leading edge, Short/Long Or for each pair of inputs: Acting directly on the corresponding outputs as blind button 2-button dimming with stop telegram or with cyclical sending 2-pushbutton sunblind control Selectable blocking of each input via a corresponding blocking object Sending of input objects after change Selectable cyclical input object sending Individual or shared configuration of actuator channels Communication objects for each blind channel for driving the sun protection into the end positions or for stopping the procedure and adjusting the blind slats in steps Communication objects for setting position of slats and blinds in percentage information Automatic opening of the blind slats to a preconfigured nominal setting after uninterrupted driving down of the blind from the top to the bottom end position, with integrated 1-bit scene control for storing and calling up (reproduction) of 2 interim blind and slat settings Integrated 1-bit/8-bit scene control, 8 scenes can be integrated per channel Optional "Sun" object for integration in a sunlight tracking control system Differentiation between automatic and manual mode and with automatic switchover from automatic to manual mode for the channel in question by pressing a bus button for manual control of the corresponding sun protection Manual mode taking precedence over automatic position commands Optional central command for each device or each channel for switching the relevant channels to automatic mode and driving the sun protection into the up or down end position Alarm: move to safety position, Locking in this position for as long as alarm is active Travel lock (e. g. for cleaning the outer shutter/blinds) Status objects for each channel for querying or for automatic sending of sun protection and slat settings as a percentage value Optional status objects for reporting that the up or down position has been reached Integrated bus coupling unit, Bus connection via bus terminal or contact system to data rail Modular installation devices for mounting on TH35 EN 60715 mounting rail

Siemens 5WG1501-1AB01

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Related Products

410455828
Siemens 410455828
View Details

Siemens

410455828

MFR #410455828

SKU #YLSL5RI1TVEAXYN

500-019614
Siemens 500-019614
View Details

Siemens

500-019614

MFR #500-019614

SKU #YLSLWCTJNEBHGM

500-688977
Siemens 500-688977
View Details

Siemens

500-688977

MFR #500-688977

SKU #YLSIOUQOSOIRZHE

5WG1125-1AB13
Siemens 5WG1125-1AB13
View Details

Siemens

5WG1125-1AB13

MFR #5WG1125-1AB13

SKU #YLSTYMOKKXUB0

5WG1125-1AB23
Siemens 5WG1125-1AB23
View Details

Siemens

5WG1125-1AB23

MFR #5WG1125-1AB23

SKU #YLSLERTZCFLXF0P

5WG1125-4CB33
Siemens 5WG1125-4CB33
View Details

Siemens

5WG1125-4CB33

MFR #5WG1125-4CB33

SKU #YLSW0XGZCPXHCDE

5WG1141-1AB14
Siemens 5WG1141-1AB14
View Details

Siemens

5WG1141-1AB14

MFR #5WG1141-1AB14

SKU #YLSVGXP12BHBWLH

5WG1141-1AB32
Siemens 5WG1141-1AB32
View Details

Siemens

5WG1141-1AB32

MFR #5WG1141-1AB32

SKU #YLSY0VBN7VTSVY

5WG1146-1AB03
Siemens 5WG1146-1AB03
View Details

Siemens

5WG1146-1AB03

MFR #5WG1146-1AB03

SKU #YLSAGHWH4KDB30E

5WG1148-1AB23
Siemens 5WG1148-1AB23
View Details

Siemens

5WG1148-1AB23

MFR #5WG1148-1AB23

SKU #YLSLJIXSIVM1Y

Featured Products

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

MTS32-150M
SMC MTS32-150M
View Details

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

Related Searches

Siemens 5WG1501-1AB01 priceSiemens 5WG1501-1AB01 quotebuy Siemens 5WG1501-1AB015WG1501-1AB01 price5WG1501-1AB01 stock availabilitySiemens spare partsSiemens 5WG1501-1AB01 equivalentSiemens 5WG1501-1AB01 specifications