
Siemens
410455828
MFR #410455828
SKU #YLSL5RI1TVEAXYN
We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Photo may not represent actual item. Refer to name and product specs for all details.
N 141/21 - KNX/DALI Gateway Twin plus, 2 channels. With emergency lighting, with sensors For communication via KNX EIB with electronic ballasts (ECG) with a DALI interface Two DALI outputs with DALI-2 certification acc. to IEC 62386-101 and 103, each for communication with up to 64 DALI ECG Ed.1 and DALI-2 and at least 10 (from which max. 8 movement detectors) DALI sensors (currently only Osram and Siemens DALI sensors are supported) Integrated power supply with input voltage AC 110-240 V, 50-60 Hz or DC 120-240 V for powering the gateway electronics and DALI output Maximum DALI output voltage of 19 V, short circuit resistant Incorrect voltage detection during commissioning if incorrect power line is connected to a DALI output LED display for displaying operation mode and error messages Pushbutton for switching between bus and direct operating mode One pair of pushbuttons for switching On/Off of all connected DALI ECG One LED per DALI output for status signal of all connected luminaries in direct mode Configurable behaviour for bus failure (stand-alone mode) Configurable pre-loaded applications without software ETS Scheduler for day, week, date with astro function Control of all connected luminaries together in broadcast mode Status signal and display of lamp and ECG failure per group and per DALI device Transformation of dimming commands into a temporary setpoint adjustment for ECG with integrated constant light level control and directly connected light level sensor One or two level timer Up to 4 integrated one time or cyclical control of repeatable sequences or color effects Distinction between self-contained emergency luminaries with one or two DALI devices Starting the self-conducted testing of each individual inverter and reporting the test result via bus or save in a persistent memory with memory space monitoring over object Distinction between function test, short duration test, and long duration test Per channel up to 6 stand-by-area analysis for activation of switch actuators Scene control for up to 16 scenes per channel 16 integrated 2-level-controller for brightness control and 16 constant light level controller for main luminaries group and up to 4 additional luminaries groups Assignment of a CIN to a DALI ECG Reintegration defective DALI ECG without ETS Assignment of DALI ECG to groups and test option for ECG, groups, scenes and effects via ETS Assignment of DALI sensors and test option of sensors via ETS Integrated bus coupling unit with only half a standard bus load, bus connection via bus terminal Mounting on DIN rail EN 60715-TH35-7.5
N 141/21 - KNX/DALI Gateway Twin plus, 2 channels. With emergency lighting, with sensors For communication via KNX EIB with electronic ballasts (ECG) with a DALI interface Two DALI outputs with DALI-2 certification acc. to IEC 62386-101 and 103, each for communication with up to 64 DALI ECG Ed.1 and DALI-2 and at least 10 (from which max. 8 movement detectors) DALI sensors (currently only Osram and Siemens DALI sensors are supported) Integrated power supply with input voltage AC 110-240 V, 50-60 Hz or DC 120-240 V for powering the gateway electronics and DALI output Maximum DALI output voltage of 19 V, short circuit resistant Incorrect voltage detection during commissioning if incorrect power line is connected to a DALI output LED display for displaying operation mode and error messages Pushbutton for switching between bus and direct operating mode One pair of pushbuttons for switching On/Off of all connected DALI ECG One LED per DALI output for status signal of all connected luminaries in direct mode Configurable behaviour for bus failure (stand-alone mode) Configurable pre-loaded applications without software ETS Scheduler for day, week, date with astro function Control of all connected luminaries together in broadcast mode Status signal and display of lamp and ECG failure per group and per DALI device Transformation of dimming commands into a temporary setpoint adjustment for ECG with integrated constant light level control and directly connected light level sensor One or two level timer Up to 4 integrated one time or cyclical control of repeatable sequences or color effects Distinction between self-contained emergency luminaries with one or two DALI devices Starting the self-conducted testing of each individual inverter and reporting the test result via bus or save in a persistent memory with memory space monitoring over object Distinction between function test, short duration test, and long duration test Per channel up to 6 stand-by-area analysis for activation of switch actuators Scene control for up to 16 scenes per channel 16 integrated 2-level-controller for brightness control and 16 constant light level controller for main luminaries group and up to 4 additional luminaries groups Assignment of a CIN to a DALI ECG Reintegration defective DALI ECG without ETS Assignment of DALI ECG to groups and test option for ECG, groups, scenes and effects via ETS Assignment of DALI sensors and test option of sensors via ETS Integrated bus coupling unit with only half a standard bus load, bus connection via bus terminal Mounting on DIN rail EN 60715-TH35-7.5

Siemens
MFR #410455828
SKU #YLSL5RI1TVEAXYN

Siemens
MFR #500-019614
SKU #YLSLWCTJNEBHGM

Siemens
MFR #500-688977
SKU #YLSIOUQOSOIRZHE

Siemens
MFR #5WG1125-1AB13
SKU #YLSTYMOKKXUB0

Siemens
MFR #5WG1125-1AB23
SKU #YLSLERTZCFLXF0P

Siemens
MFR #5WG1125-4CB33
SKU #YLSW0XGZCPXHCDE

Siemens
MFR #5WG1141-1AB14
SKU #YLSVGXP12BHBWLH

Siemens
MFR #5WG1141-1AB32
SKU #YLSY0VBN7VTSVY

Siemens
MFR #5WG1146-1AB03
SKU #YLSAGHWH4KDB30E

Siemens
MFR #5WG1148-1AB23
SKU #YLSLJIXSIVM1Y

SMC
MFR #AW20-N02CG-6CZ-B
SKU #YLSNOOF0IBCZ3J3

SMC
MFR #MXS-AS16L
SKU #YLSAP0XXFGFSWY6

SMC
MFR #VQC2101R-51
SKU #YLSSEY6NT0YLZ8G

SMC
MFR #MXQ25L-40B-M9NZ
SKU #YLSD1VANMRI726Z

SMC
MFR #CM2B40-75Z
SKU #YLSOGLJ512KWTEJ

SMC
MFR #AR30-N02E-1Z-B
SKU #YLSYFNHADE6GRKV

Danfoss Aeroquip LLC
MFR #EH22512
SKU #YLSRZ91UGVO64DG

SMC
MFR #MDBB63-100Z
SKU #YLSNBPQBGLI90UX

SMC
MFR #NCDMC150-0600-X155US
SKU #YLS8ICKGSKYC93L

SMC
MFR #MGPM25-100Z-XC4
SKU #YLSH71U0VZZBO5I
Siemens 5WG1141-1AB21 priceSiemens 5WG1141-1AB21 quotebuy Siemens 5WG1141-1AB215WG1141-1AB21 price5WG1141-1AB21 stock availabilitySiemens spare partsSiemens 5WG1141-1AB21 equivalentSiemens 5WG1141-1AB21 specifications