Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3UF7600-1AB01-0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3UF7600-1AB01-0

multifunction module, 4 inputs and 2 relay outputs, input voltage 24 V DC, relay outputs monostable, analog residual current detection, with residual-current transformer 3UL23 connection temperature sensor Pt100/Pt1000/KTY/NTC, max. 1 multifunction module per basic device SIMOCODE pro S

SiemensMFR # 3UF7600-1AB01-0SKU # CEY-937FC780B99F
product brand nameSIMOCODE
product designationMultifunction module
product type designationMM
input for thermistor connectionNo
digital inputYes
input for residual current converterYes
Share

About This Product

multifunction module, 4 inputs and 2 relay outputs, input voltage 24 V DC, relay outputs monostable, analog residual current detection, with residual-current transformer 3UL23 connection temperature sensor Pt100/Pt1000/KTY/NTC, max. 1 multifunction module per basic device SIMOCODE pro S

Siemens 3UF7600-1AB01-0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIMOCODE
product designationMultifunction module
product type designationMM
1 of residual current transformer connectable3UL2302-1A
2 of residual current transformer connectable3UL2303-1A
3 of residual current transformer connectable3UL2304-1A
4 of residual current transformer connectable3UL2305-1A
5 of residual current transformer connectable3UL2306-1A
6 of residual current transformer connectable3UL2307-1A
General technical data
product function residual current displayYes
adjustable current response value current40 ... 0.03 A
input for thermistor connectionNo
digital inputYes
input for residual current converterYes
input for analog temperature sensorsYes
input for ground fault detectionYes
relay outputYes
consumed active power0.8 W
insulation voltage with degree of pollution 3 at AC rated value300 V
surge voltage resistance rated value4 000 V
when mounted on current measuring module according to IEC 60068-2-2710 g / 11 ms
according to IEC 60068-2-2715 g / 11 ms
according to IEC 60068-2-61 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2 g
when mounted on current measuring module according to IEC 60068-2-61 ... 4 Hz / 15 mm, 4 ... 500 Hz / 1g
at 24 V6 A
at 120 V6 A
at 230 V3 A
at 24 V2 A
at 60 V0.55 A
at 125 V0.25 A
mechanical service life (operating cycles) typical10 000 000
electrical endurance (operating cycles) typical100 000
buffering time in the event of power failure0 s
reference code according to IEC 81346-2K
at 50 °C6 A
at 60 °C5 A
Substance Prohibitance (day/month/year)05/01/2012
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1
Net Weight0.207 kg
with NTC minimum80 °C
with NTC maximum160 °C
with KTY 84 minimum-40 °C
with KTY 84 maximum300 °C
with KTY 83-110 minimum-50 °C
with KTY 83-110 maximum175 °C
with Pt 1000 minimum-50 °C
with Pt 1000 maximum500 °C
with Pt 100 minimum-50 °C
with Pt 100 maximum500 °C
relative temperature-related measurement deviation at 20 °C2 %
sensor current for Pt 100 typical1 mA
sensor current for Pt 1000/KTY 83-110/KTY 84/NTC typical0.2 mA
short-circuit detectionYes
open-circuit detectionYes
short-circuit detectionYes
open-circuit detectionYes
short-circuit detectionYes
open-circuit detectionYes
short-circuit detectionYes
open-circuit detectionYes
short-circuit detectionYes
open-circuit detectionNo
type of connection technology of sensor circuit2-wire or 3-wire connection
A/D conversion time at sensor circuit500 ms
measurable line frequency initial value16 Hz
measurable line frequency full-scale value400 Hz
Electromagnetic compatibility
EMC emitted interference according to IEC 60947-1class A
EMC immunity according to IEC 60947-1corresponds to degree of severity 3
due to burst according to IEC 61000-4-42 kV (power ports) / 1 kV (signal ports)
due to conductor-earth surge according to IEC 61000-4-52 kV
due to conductor-conductor surge according to IEC 61000-4-51 kV
due to high-frequency radiation according to IEC 61000-4-610 V
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
conducted HF interference emissions according to CISPR11corresponds to degree of severity A
field-bound HF interference emission according to CISPR11corresponds to degree of severity A
Inputs/ Outputs
parameterizable inputsYes
parameterizable outputsYes
number of inputs4
number of digital inputs4
with a common reference potential4
type 1 acc. to IEC 61131No
type 2 acc. to IEC 61131Yes
number of analog inputs0
for ground fault detection1
for temperature measurement1
input voltage at digital input at DC rated value24 V
number of outputs2
number of semiconductor outputs0
number of outputs as contact-affected switching element2
number of analog outputs0
switching behaviormonostable
property of contacts of the relay outputsFloating NO contacts (NC reaction parameterizable via internal signal conditioning), of which 2 relay outputs connected to common ground and one relay output separately, can be freely assigned to the control functions (e.g. line, star (wye), delta contactor or signaling of the operating state)
wire length for digital signals maximum300 m
Protective and monitoring functions
product function ground fault detectionYes
type of current for monitoringType A (alternating currents and pulsing DC residual currents)
response time maximum0 s
diagnostics function at sensor input with residual current transformer short-circuit detectionYes
diagnostics function at sensor input with residual current transformer open-circuit detectionYes
relative measurement deviation of residual current transformer7.5 %
design of the sensor for temperature measurement connectablePT100 / PT1000 / KTY83-110 / KTY84 / NTC
Precision
temperature drift per °C0.05 %/°C
Installation/ mounting/ dimensions
mounting positionany
height100 mm
width22.5 mm
depth124.5 mm
top40 mm
bottom40 mm
left0 mm
right0 mm
diameter of inlet opening of connectable residual current transformer35 ... 210 mm
Connections/ Terminals
product component removable terminal for auxiliary and control circuitYes
type of electrical connection for auxiliary and control circuitscrew-type terminals
solid1x (0.5 ... 2.5 mm²), 2x ( 0.5 ... 1.5 mm²)
finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
for AWG cables solid1x (20 ... 14), 2x (20 ... 16)
for AWG cables stranded1x (20 ... 12), 2x (20 ... 14)
tightening torque with screw-type terminals0.6 ... 0.8 N·m
tightening torque [lbf·in] with screw-type terminals5.2 ... 7 lbf·in
Ambient conditions
1 maximum2 000 m
2 maximum3 000 m; max. +50 °C (no protective separation)
3 maximum4 000 m; No protective separation at 40 °C
during operation-25 ... +60 °C
during storage-40 ... +80 °C
during transport-40 ... +80 °C
during operation according to IEC 607213K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
during storage according to IEC 607211K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4
during transport according to IEC 607212K2, 2C1, 2S1, 2M2
relative humidity during operation10 ... 95 %
contact rating of auxiliary contacts according to ULB300 / R300
Short-circuit protection
design of short-circuit protection per outputFuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A)
Electrical Safety
touch protection against electrical shockfinger-safe
ATEX
certificate of suitability according to ATEX directive 2014/34/EUBVS 06 ATEX F001
explosion device group and category according to ATEX directive 2014/34/EUII (2) G, II (2 ) D, I (M2)
Galvanic isolation
(electrically) protective separation according to IEC 60947-1All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information)
galvanic isolation between inputs and electronicsNo
Control circuit/ Control
type of voltage of the control supply voltageDC
control supply voltage at DC rated value24 V
initial value0.8
full-scale value1.2

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

MXQ25L-40B-M9NZ
SMC MXQ25L-40B-M9NZ
View Details

SMC

MXQ25L-40B-M9NZ

MFR #MXQ25L-40B-M9NZ

SKU #YLSD1VANMRI726Z

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
View Details

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

Related Searches

Siemens 3UF7600-1AB01-0 priceSiemens 3UF7600-1AB01-0 quotebuy Siemens 3UF7600-1AB01-03UF7600-1AB01-0 price3UF7600-1AB01-0 stock availabilitySiemens spare partsSiemens 3UF7600-1AB01-0 equivalentSiemens 3UF7600-1AB01-0 specifications