Siemens 3UF7123-1AA01-0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3UF7123-1AA01-0

current/voltage measuring module for dry-running protection of centrifugal pumps in hazardous areas, current setting 20...200 A voltage measurement up to 690 V, width 120 mm, straight-through transformer

SiemensMFR # 3UF7123-1AA01-0SKU # YLSL9RJLAY0ZYG
product brand nameSIMOCODE
product designationCurrent/voltage measuring module
product type designationIUM
measuring procedureRMS value measurement
size of the circuit-breakerS6
current measurementYes
Share

About This Product

current/voltage measuring module for dry-running protection of centrifugal pumps in hazardous areas, current setting 20...200 A voltage measurement up to 690 V, width 120 mm, straight-through transformer

Siemens 3UF7123-1AA01-0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIMOCODE
product designationCurrent/voltage measuring module
product type designationIUM
General technical data
measuring procedureRMS value measurement
size of the circuit-breakerS6
current measurementYes
voltage measurementYes
active power measurementYes
energy measurementYes
frequency measurementYes
active power monitoring for pump dry-run according to Ignition protection type Ex bYes
measuring procedure for current measurementTRMS
current measuring range extension with external current transformersNo
measuring procedure for voltage measurementTRMS
measurable supply voltage between the line conductors at AC maximum rated value690 V
input for thermistor connectionNo
consumed active power0.5 W
with degree of pollution 3 at AC rated value690 V
for wires of main circuit according to IEC 60947-1 rated value6 kV
surge voltage resistance rated value6 000 V
shock resistance according to IEC 60068-2-2715 g / 11 ms; with basic unit snapped on
vibration resistance1 … 6 Hz / 15 mm; 6 … 500 Hz / 2 g; with basic unit snapped on: 1 g
Substance Prohibitance (day/month/year)05/28/2009
SVHC substance nameLead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1
Net Weight0.581 kg
Electromagnetic compatibility
EMC emitted interference according to IEC 60947-1class A
EMC immunity according to IEC 60947-1corresponds to degree of severity 3
due to burst according to IEC 61000-4-42 kV
due to conductor-earth surge according to IEC 61000-4-52 kV
due to conductor-conductor surge according to IEC 61000-4-51 kV
field-based interference according to IEC 61000-4-310 V/m
Inputs/ Outputs
number of outputs as contact-affected switching element0
Protective and monitoring functions
power factor monitoringYes
ground-fault monitoringYes
voltage detectionYes
trip classCLASS 5E, 7E, 10E, 15E, 20E, 25E, 30E, 35E and 40E adjustable
current detectionYes
overload protectionYes
Precision
of frequency measurement+/- 1.5 %, 15 A ... 400 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C
for current measurement 1+/- 1.5 %, in range 400 A ... 1600 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C
for current measurement 2+/- 5%, in range 400 A ... 1600 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C
for voltage measurement 1+/- 1.5 %, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C
at cos phi-measurement 1+/- 1.5 %, 15 A ... 400 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C
at cos phi-measurement 2+/- 5%, 400 A ... 1600 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
for active power measurement 1+/- 5%, 15 A ... 400 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
for active power measurement 2+/- 10%, 400 A ... 1600 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
for energy measurement 1+/- 5%, 47 A ... 1260 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
for energy measurement 2+/- 10%, 400 A ... 1600 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
for apparent power measurement 1+/- 3%, 15 A ... 400 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
for apparent power measurement 2+/- 5 %, 400 A ... 1600 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C
accuracy of ground-fault monitoringIn the range 30 % .. 120 %/Is: +/- 10 % (Class CI-A), in range 15 % .. 30 % Ie: +/- 25 % (Class CI-B), both values acc. to IEC 60947-1 Annex T
temperature drift per °C0.01 %/°C; Reference temperature: 25°C
measured variable frequency45 ... 65 Hz
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew and snap-on mounting
height95 mm
width120 mm
depth145 mm
top30 mm
bottom30 mm
left0 mm
right0 mm
diameter of inlet opening25 mm
diameter of inlet opening for current measurement25 mm
Connections/ Terminals
for main current circuitstraight-through transformers
for auxiliary and control circuitscrew-type terminals
type of electrical connection at the measurement inputs for voltagescrew-type terminals
finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
solid1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
for AWG cables solid1x (20 ... 12), 2x (20 ... 14)
for AWG cables stranded1x (20 ... 14), 2x (20 ... 16)
tightening torque at the measurement inputs for voltage0.8 ... 1.2 N·m
tightening torque [lbf·in] at the measurement inputs for voltage7 ... 10.3 lbf·in
test voltage for isolation test noteFor insulation tests, it is recommended to disconnect the voltage terminals; this is mandatory for DC test voltages.
Ambient conditions
1 maximum2 000 m
2 maximum3 000 m; max. +50 °C (no protective separation)
3 maximum4 000 m; max. +40 °C (no protective separation)
during operation-25 ... +60 °C
during storage-40 ... +80 °C
during transport-40 ... +80 °C
during operation according to IEC 607213K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
during storage according to IEC 607211K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4
during transport according to IEC 607212K2, 2C1, 2S1, 2M2
relative humidity during operation10 ... 95 %
Short-circuit protection
product function short circuit protectionNo
IEC 61508
Safety Integrity Level (SIL) according to IEC 615081
ATEX
IECExYes; IECEx PTB 18.0004X
according to ATEX directive 2014/34/EUBVS 06 ATEX F001, PTB 18 ATEX 5003 X
according to UKCAITS21UKEX0464, ITS21UKEX0455X
explosion device group and category according to ATEX directive 2014/34/EUII (2) G, II (2 ) D, I (M2) / I (M2), II (1/2) G, II (1G/2D)
Galvanic isolation
(electrically) protective separation according to IEC 60947-1All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information)
Main circuit
number of poles for main current circuit3
adjustable current response value current of the current-dependent overload release20 ... 200 A
— at 50 Hz rated value110 ... 690 V
— at 60 Hz rated value110 ... 690 V
operating frequency rated value50 ... 60 Hz
Control circuit/ Control
type of voltageAC
inrush current maximum2 000 A; 10 x Io
Product information
EAN4047621058221
UPC804766765520
Product familySIMOCODE pro 3UF7 motor management and control devices
Life cycle statusActive
Commodity code85371098
Delivery and logistics
Country of originGermany
Standard delivery time5 Day/Days
ReturnableYes
Net weight0.581 Kg
Packaging dimensions (L x W x H)145 x 139 x 175 MM
Standard package quantity1 Piece
Minimum order quantity1
Dangerous goodsNo
Export control regulationsAL : N / ECCN : 9N9999
Environment and compliance
RoHS conformitySince: 28-05-09
WEEE category5
REACH informationLead monoxide (lead oxide) CAS-No. 1317-36-8 > 0,1 % (w / w)
SCIP numberbd290299-9e56-4340-8e9e-c22b9cc3bfd8
Siemens catalog
Product group5836
Catalog IDCC-IC10
Group codeR711
Product classStraightforward, can be reused over the short term

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

AW20-N02CG-6CZ-B
SMC AW20-N02CG-6CZ-B
View Details

SMC

AW20-N02CG-6CZ-B

MFR #AW20-N02CG-6CZ-B

SKU #YLSNOOF0IBCZ3J3

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

MY1M20-200AH
SMC MY1M20-200AH
View Details

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
View Details

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

Related Searches

Siemens 3UF7123-1AA01-0 priceSiemens 3UF7123-1AA01-0 quotebuy Siemens 3UF7123-1AA01-03UF7123-1AA01-0 price3UF7123-1AA01-0 stock availabilitySiemens spare partsSiemens 3UF7123-1AA01-0 equivalentSiemens 3UF7123-1AA01-0 specifications