basic device SIMOCODE pro V EIP, EtherNet/IP, media redundancy, DLR (max. 20 participants) web server, transfer rate 100 Mbps, 2 x bus connection via RJ45, 4 I/3 O freely configurable, Us: 110...240 V AC/DC, input for thermistor connection monostable relay outputs, expandable by expansion modules

SiemensMFR # 3UF7013-1AU00-0SKU # YLSIZKUXCWJZV7
product brand nameSIMOCODE
product designationMotor management system
design of the productbasic unit 3
product type designationpro V EIP
current measurementNo
voltage measurementNo
Share

About This Product

basic device SIMOCODE pro V EIP, EtherNet/IP, media redundancy, DLR (max. 20 participants) web server, transfer rate 100 Mbps, 2 x bus connection via RJ45, 4 I/3 O freely configurable, Us: 110...240 V AC/DC, input for thermistor connection monostable relay outputs, expandable by expansion modules

Siemens 3UF7013-1AU00-0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIMOCODE
product designationMotor management system
design of the productbasic unit 3
product type designationpro V EIP
General technical data
current measurementNo
voltage measurementNo
active power measurementYes
energy measurementNo
frequency measurementNo
bus communicationYes
data acquisition functionYes
diagnostics functionYes
password protectionYes
test functionYes
maintenance functionYes
MRRT redundancy procedureNo
input for thermistor connectionYes
digital inputYes
input for analog temperature sensorsNo
input for ground fault detectionNo
relay outputYes
temperature monitoring moduleYes
current measuring moduleYes
current/voltage measuring moduleYes
fail-safe digital I/O moduleYes
ground-fault monitoring moduleYes
decoupling moduleYes
analog I/O moduleYes
digital I/O module with monostable outputsYes
digital I/O module with bistable outputsYes
control unit with displayYes
control unitYes
apparent power consumption8.3 V·A
consumed active power4.8 W
insulation voltage with degree of pollution 3 at AC rated value300 V
surge voltage resistance rated value4 000 V
according to IEC 60068-2-2715 g / 11 ms
vibration resistance1 … 6 Hz / 15 mm; 6 … 500 Hz / 2 g
at 24 V6 A
at 120 V6 A
at 230 V3 A
at 24 V2 A
at 60 V0.55 A
at 125 V0.25 A
mechanical service life (operating cycles) typical10 000 000
electrical endurance (operating cycles) typical100 000
buffering time in the event of power failure0.02 s
reference code according to IEC 81346-2F
at 50 °C6 A
at 60 °C5 A
type of input characteristicType 1 in accordance with EN 61131-2
Substance Prohibitance (day/month/year)03/01/2017
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1 4,4'-isopropylidenediphenol (Bisphenol A, BPA) CAS-No. 80-05-7 2-benzyl-2-dimethylamino-4'-morpholinobutyrophenone CAS-No. 119313-12-1
Net Weight0.305 kg
Electromagnetic compatibility
EMC emitted interference according to IEC 60947-1class A
EMC immunity according to IEC 60947-1corresponds to degree of severity 3
due to burst according to IEC 61000-4-42 kV (power ports) / 1 kV (signal ports)
due to conductor-earth surge according to IEC 61000-4-52 kV
due to conductor-conductor surge according to IEC 61000-4-51 kV
due to high-frequency radiation according to IEC 61000-4-610 V
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
conducted HF interference emissions according to CISPR11corresponds to degree of severity A
field-bound HF interference emission according to CISPR11corresponds to degree of severity A
Inputs/ Outputs
parameterizable inputsYes
parameterizable outputsYes
number of inputs4
for thermistor connection1
number of digital inputs with a common reference potential4
type 1 acc. to IEC 61131Yes
rated value24 V
number of outputs3
number of semiconductor outputs0
number of outputs as contact-affected switching element3
switching behaviormonostable
number of relay outputs3
type of relay outputsMonostable
wire length for digital signals maximum300 m
with conductor cross-section = 0.5 mm² maximum50 m
with conductor cross-section = 1.5 mm² maximum150 m
with conductor cross-section = 2.5 mm² maximum250 m
Protective and monitoring functions
asymmetry detectionYes
blocking current evaluationYes
power factor monitoringYes
ground fault detectionYes
ground-fault monitoringNo
phase failure detectionYes
phase sequence recognitionYes
voltage detectionYes
monitoring of number of start operationsYes
overvoltage detectionYes
overcurrent detection 1 phaseYes
undervoltage detectionYes
undercurrent detection 1 phaseYes
active power monitoringYes
current detectionYes
overload protectionYes
evaluation of thermistor motor protectionYes
total cold resistance number of sensors in series maximum1.5 kΩ
response value of thermoresistor3 400 ... 3 800 Ω
of the short-circuit control9 Ω
release value of thermoresistor1 500 ... 1 650 Ω
Motor control functions
parameterizable overload relayYes
circuit breaker controlYes
direct startYes
reverse startingYes
star-delta circuitYes
star-delta reversing circuitYes
Dahlander circuitYes
Dahlander reversing circuitYes
pole-changing switch circuitYes
pole-changing switch reversing circuitYes
slide controlYes
valve controlYes
Communication/ Protocol
PROFIBUS DP protocolNo
PROFINET IO protocolNo
PROFIsafe protocolNo
Modbus RTUNo
EtherNet/IPYes
OPC UA ServerNo
LLDPYes
Address Resolution Protocol (ARP)Yes
SNMPYes
HTTPSNo
NTPYes
Media Redundancy Protocol (MRP)No
web serverYes
shared deviceNo
at the Ethernet interface AutocrossoverYes
at the Ethernet interface AutonegotiationYes
at the Ethernet interface AutosensingYes
is supported Device Level Ring (DLR)Yes
is supported PROFINET system redundancy (S2)No
supports PROFIenergy measured valuesNo
supports PROFIenergy shutdownNo
transfer rate maximum100 Mbit/s
I&M0 - device-specific informationNo
I&M1 - higher level designation/location designationNo
I&M2 - installation dateNo
I&M3 - commentNo
type of electrical connection of the communication interface2x RJ45
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew and snap-on mounting
height111 mm
width45 mm
depth124 mm
top40 mm
bottom40 mm
left0 mm
right0 mm
Connections/ Terminals
product component removable terminal for auxiliary and control circuitYes
for auxiliary and control circuitscrew-type terminals
solid1x (0.5 ... 4.0mm²), 2x (0.5 ... 2.5 mm²)
finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
for AWG cables solid1x (20 ... 12), 2x (20 ... 14)
for AWG cables stranded1x (20 ... 14), 2x (20 ... 16)
tightening torque with screw-type terminals0.8 ... 1.2 N·m
tightening torque [lbf·in] with screw-type terminals7 ... 10.3 lbf·in
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-25 ... +60 °C
during storage-40 ... +80 °C
during transport-40 ... +80 °C
during operation according to IEC 607213K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
during storage according to IEC 607211K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4
during transport according to IEC 607212K2, 2C1, 2S1, 2M2
during operation5 ... 95 %
contact rating of auxiliary contacts according to ULB300 / R300
Short-circuit protection
design of short-circuit protection per outputFuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A)
Electrical Safety
touch protection against electrical shockfinger-safe
ATEX
IECExYes; IECEx BVS 20.0020 / IECEx PTB 18.0004X
according to ATEX directive 2014/34/EUBVS 06 ATEX F001, PTB 18 ATEX 5003 X
acc. to Equipment and Protective System Intended for Use in Potentially Explosive Atmospheres Regulations 2016 (S.I. 2016 No.1107)ITS21UKEX0464, ITS21UKEX0455X
according to UKCAITS21UKEX0464, ITS21UKEX0455X
explosion device group and category according to ATEX directive 2014/34/EUI (M2), II (2) G, II (2) D / I (M2), II (1/2) G, II (1G/2D)
Galvanic isolation
(electrically) protective separation according to IEC 60947-1All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information)
design of the electrical isolationProtective separation in accordance with IEC 60947-1 for all circuits
Control circuit/ Control
product function soft starter controlYes
type of voltage of the control supply voltageAC/DC
at 50 Hz rated value110 ... 240 V
at 60 Hz rated value110 ... 240 V
1 rated value50 Hz
2 rated value60 Hz
relative symmetrical tolerance of the control supply voltage frequency5 %
control supply voltage at DC rated value110 ... 240 V
initial value0.85
full-scale value1.1
initial value0.85
full-scale value1.1
initial value0.85
full-scale value1.1
at 240 V5 A
at 240 V1 ms
Product information
EAN4047621014869
UPC804766405136
Product familySIMOCODE pro 3UF7 motor management and control devices
Life cycle statusActive
Commodity code85371098
Delivery and logistics
Country of originGermany
Standard delivery time5 Day/Days
ReturnableYes
Net weight0.305 Kg
Packaging dimensions (L x W x H)132 x 58 x 135 MM
Standard package quantity1 Piece
Minimum order quantity1
Dangerous goodsNo
Export control regulationsAL : N / ECCN : 9N9999
Environment and compliance
RoHS conformitySince: 01-03-17
WEEE category5
REACH informationLead CAS-No. 7439-92-1 > 0,1 % (w / w)
SCIP number422508cf-4d6d-4759-8dc9-b7c98424c0a1
Siemens catalog
Product group5836
Catalog IDCC-IC10
Group codeR711
Product classStraightforward, can be reused over the short term

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
View Details

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

MXS-AS16L
SMC MXS-AS16L
View Details

SMC

MXS-AS16L

MFR #MXS-AS16L

SKU #YLSAP0XXFGFSWY6

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

MXQ25L-40B-M9NZ
SMC MXQ25L-40B-M9NZ
View Details

SMC

MXQ25L-40B-M9NZ

MFR #MXQ25L-40B-M9NZ

SKU #YLSD1VANMRI726Z

Related Searches

Siemens 3UF7013-1AU00-0 priceSiemens 3UF7013-1AU00-0 quotebuy Siemens 3UF7013-1AU00-03UF7013-1AU00-0 price3UF7013-1AU00-0 stock availabilitySiemens spare partsSiemens 3UF7013-1AU00-0 equivalentSiemens 3UF7013-1AU00-0 specifications