basic device SIMOCODE pro V PN, Ethernet/PROFINET IO, PN system redundancy, OPC UA server, web server, transfer rate 100 Mbps, 2 x bus connection via RJ45, 4 I/3 O freely configurable, Us: 110...240 V AC/DC, input for thermistor connection monostable relay outputs, expandable by expansion modules

SiemensMFR # 3UF7011-1AU00-0SKU # CEY-8EF3B038DD6A
product brand nameSIMOCODE
product designationMotor management system
design of the productbasic unit 3
product type designationpro V PN
current measurementNo
voltage measurementNo
Share

About This Product

basic device SIMOCODE pro V PN, Ethernet/PROFINET IO, PN system redundancy, OPC UA server, web server, transfer rate 100 Mbps, 2 x bus connection via RJ45, 4 I/3 O freely configurable, Us: 110...240 V AC/DC, input for thermistor connection monostable relay outputs, expandable by expansion modules

Siemens 3UF7011-1AU00-0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIMOCODE
product designationMotor management system
design of the productbasic unit 3
product type designationpro V PN
General technical data
current measurementNo
voltage measurementNo
active power measurementYes
energy measurementNo
frequency measurementNo
bus communicationYes
data acquisition functionYes
diagnostics functionYes
password protectionYes
test functionYes
maintenance functionYes
input for thermistor connectionYes
digital inputYes
input for analog temperature sensorsNo
input for ground fault detectionNo
relay outputYes
temperature monitoring moduleYes
current measuring moduleYes
current/voltage measuring moduleYes
fail-safe digital I/O moduleYes
ground-fault monitoring moduleYes
decoupling moduleYes
analog I/O moduleYes
digital I/O module with monostable outputsYes
digital I/O module with bistable outputsYes
control unit with displayYes
control unitYes
apparent power consumption8.3 V·A
consumed active power4.5 W
insulation voltage with degree of pollution 3 at AC rated value300 V
surge voltage resistance rated value4 000 V
according to IEC 60068-2-2715 g / 11 ms
vibration resistance1 … 6 Hz / 15 mm; 6 … 500 Hz / 2 g
at 24 V6 A
at 120 V6 A
at 230 V3 A
at 24 V2 A
at 60 V0.55 A
at 125 V0.25 A
mechanical service life (operating cycles) typical10 000 000
electrical endurance (operating cycles) typical100 000
buffering time in the event of power failure0.02 s
reference code according to IEC 81346-2F
at 50 °C6 A
at 60 °C5 A
type of input characteristicType 1 in accordance with EN 61131-2
Substance Prohibitance (day/month/year)03/01/2017
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1 4,4'-isopropylidenediphenol (Bisphenol A, BPA) CAS-No. 80-05-7 2-benzyl-2-dimethylamino-4'-morpholinobutyrophenone CAS-No. 119313-12-1
Net Weight0.307 kg
Electromagnetic compatibility
EMC emitted interference according to IEC 60947-1class A
EMC immunity according to IEC 60947-1corresponds to degree of severity 3
due to burst according to IEC 61000-4-42 kV (power ports) / 1 kV (signal ports)
due to conductor-earth surge according to IEC 61000-4-52 kV
due to conductor-conductor surge according to IEC 61000-4-51 kV
due to high-frequency radiation according to IEC 61000-4-610 V
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
conducted HF interference emissions according to CISPR11corresponds to degree of severity A
field-bound HF interference emission according to CISPR11corresponds to degree of severity A
Inputs/ Outputs
parameterizable inputsYes
parameterizable outputsYes
number of inputs4
for thermistor connection1
number of digital inputs with a common reference potential4
type 1 acc. to IEC 61131Yes
rated value24 V
number of outputs3
number of semiconductor outputs0
number of outputs as contact-affected switching element3
switching behaviormonostable
number of relay outputs3
type of relay outputsMonostable
wire length for digital signals maximum300 m
with conductor cross-section = 0.5 mm² maximum50 m
with conductor cross-section = 1.5 mm² maximum150 m
with conductor cross-section = 2.5 mm² maximum250 m
Protective and monitoring functions
asymmetry detectionYes
blocking current evaluationYes
power factor monitoringYes
ground fault detectionYes
ground-fault monitoringNo
phase failure detectionYes
phase sequence recognitionYes
voltage detectionYes
monitoring of number of start operationsYes
overvoltage detectionYes
overcurrent detection 1 phaseYes
undervoltage detectionYes
undercurrent detection 1 phaseYes
active power monitoringYes
current detectionYes
overload protectionYes
evaluation of thermistor motor protectionYes
total cold resistance number of sensors in series maximum1.5 kΩ
response value of thermoresistor3 400 ... 3 800 Ω
of the short-circuit control9 Ω
release value of thermoresistor1 500 ... 1 650 Ω
Motor control functions
parameterizable overload relayYes
circuit breaker controlYes
direct startYes
reverse startingYes
star-delta circuitYes
star-delta reversing circuitYes
Dahlander circuitYes
Dahlander reversing circuitYes
pole-changing switch circuitYes
pole-changing switch reversing circuitYes
slide controlYes
valve controlYes
Communication/ Protocol
PROFIBUS DP protocolNo
PROFINET IO protocolYes
PROFIsafe protocolYes
Modbus RTUNo
EtherNet/IPNo
OPC UA ServerYes
LLDPYes
Address Resolution Protocol (ARP)Yes
SNMPYes
HTTPSYes
NTPYes
Media Redundancy Protocol (MRP)Yes
web serverYes
shared deviceYes
at the Ethernet interface AutocrossoverYes
at the Ethernet interface AutonegotiationYes
at the Ethernet interface AutosensingYes
Media Redundancy Protocol for Planned Duplication (MRPD)Yes
is supported Device Level Ring (DLR)No
is supported PROFINET system redundancy (S2)Yes
supports PROFIenergy measured valuesYes
supports PROFIenergy shutdownYes
transfer rate100 Mbit/s
transfer rate maximum100 Mbit/s
PROFINET conformity classC
I&M0 - device-specific informationYes
I&M1 - higher level designation/location designationYes
I&M2 - installation dateYes
I&M3 - commentYes
type of electrical connection of the communication interface2x RJ45
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew and snap-on mounting
height111 mm
width45 mm
depth124 mm
top40 mm
bottom40 mm
left0 mm
right0 mm
Connections/ Terminals
product component removable terminal for auxiliary and control circuitYes
for auxiliary and control circuitscrew-type terminals
solid1x (0.5 ... 4.0mm²), 2x (0.5 ... 2.5 mm²)
finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
for AWG cables solid1x (20 ... 12), 2x (20 ... 14)
for AWG cables stranded1x (20 ... 14), 2x (20 ... 16)
tightening torque with screw-type terminals0.8 ... 1.2 N·m
tightening torque [lbf·in] with screw-type terminals7 ... 10.3 lbf·in
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-25 ... +60 °C
during storage-40 ... +80 °C
during transport-40 ... +80 °C
during operation according to IEC 607213K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
during storage according to IEC 607211K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4
during transport according to IEC 607212K2, 2C1, 2S1, 2M2
during operation5 ... 95 %
contact rating of auxiliary contacts according to ULB300 / R300
Short-circuit protection
design of short-circuit protection per outputFuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A)
Electrical Safety
touch protection against electrical shockfinger-safe
ATEX
IECExYes; IECEx BVS 20.0020 / IECEx PTB 18.0004X
according to ATEX directive 2014/34/EUBVS 06 ATEX F001, PTB 18 ATEX 5003 X
according to UKCAITS21UKEX0464, ITS21UKEX0455X
explosion device group and category according to ATEX directive 2014/34/EUI (M2), II (2) G, II (2) D / I (M2), II (1/2) G, II (1G/2D)
Galvanic isolation
(electrically) protective separation according to IEC 60947-1All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information)
design of the electrical isolationProtective separation in accordance with IEC 60947-1 for all circuits
Control circuit/ Control
product function soft starter controlYes
type of voltage of the control supply voltageAC/DC
at 50 Hz rated value110 ... 240 V
at 60 Hz rated value110 ... 240 V
1 rated value50 Hz
2 rated value60 Hz
relative symmetrical tolerance of the control supply voltage frequency5 %
control supply voltage at DC rated value110 ... 240 V
initial value0.85
full-scale value1.1
initial value0.85
full-scale value1.1
initial value0.85
full-scale value1.1
at 240 V15 A
at 240 V1 ms

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

AW20-N02CG-6CZ-B
SMC AW20-N02CG-6CZ-B
View Details

SMC

AW20-N02CG-6CZ-B

MFR #AW20-N02CG-6CZ-B

SKU #YLSNOOF0IBCZ3J3

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
View Details

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
View Details

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

Related Searches

Siemens 3UF7011-1AU00-0 priceSiemens 3UF7011-1AU00-0 quotebuy Siemens 3UF7011-1AU00-03UF7011-1AU00-0 price3UF7011-1AU00-0 stock availabilitySiemens spare partsSiemens 3UF7011-1AU00-0 equivalentSiemens 3UF7011-1AU00-0 specifications