Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3TF6833-1QG7-ZA02

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3TF6833-1QG7-ZA02

vacuum contactor AC-3e/AC-3 630 A, 335 kW / 400 V, Ue 690 V, 3-pole, Uc: 110-120 V AC(50/60 Hz) drive: conventional rectifier bridge built-in with reversing contactor 3TC44 auxiliary contacts 3 NO + 3 NC main circuit: busbar control and auxiliary circuit: screw terminal without overvoltage damping in main circuit

SiemensMFR # 3TF6833-1QG7-ZA02SKU # CEY-8EF3B038E594
product designationVacuum contactor
product type designation3TF6
size of contactor14
function module for communicationNo
auxiliary switchNo
of main circuit rated value8 kV
Share

About This Product

vacuum contactor AC-3e/AC-3 630 A, 335 kW / 400 V, Ue 690 V, 3-pole, Uc: 110-120 V AC(50/60 Hz) drive: conventional rectifier bridge built-in with reversing contactor 3TC44 auxiliary contacts 3 NO + 3 NC main circuit: busbar control and auxiliary circuit: screw terminal without overvoltage damping in main circuit

Siemens 3TF6833-1QG7-ZA02

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product designationVacuum contactor
product type designation3TF6
General technical data
size of contactor14
function module for communicationNo
auxiliary switchNo
of main circuit with degree of pollution 3 rated value1 000 V
of auxiliary circuit with degree of pollution 3 rated value690 V
of main circuit rated value8 kV
of auxiliary circuit rated value6 kV
in networks with grounded star point between auxiliary and auxiliary circuit300 V
in networks with grounded star point between main and auxiliary circuit500 V
at AC8.1 g / 5 ms, 4.7 g / 10 ms
at AC12.8 g / 5 ms, 7.4 g / 10 ms
of contactor typical5 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)03/01/2017
SVHC substance nameLead CAS-No. 7439-92-1 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1
Net Weight21.022 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-25 ... +55 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity during operation10 ... 95 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
type of voltage for main current circuitAC
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
— up to 690 V at ambient temperature 40 °C rated value700 A
— up to 690 V at ambient temperature 55 °C rated value630 A
— at 400 V rated value630 A
— at 500 V rated value630 A
— at 690 V rated value630 A
— at 400 V rated value552 A
— at 500 V rated value552 A
— at 690 V rated value552 A
at AC-4 at 400 V rated value610 A
— up to 500 V for current peak value n=20 rated value513 A
— up to 690 V for current peak value n=20 rated value513 A
— up to 400 V for current peak value n=30 rated value342 A
— up to 500 V for current peak value n=30 rated value342 A
— up to 690 V for current peak value n=30 rated value342 A
at 40 °C minimum permissible480 mm²
at 400 V rated value300 A
at 690 V rated value300 A
— at 230 V rated value200 kW
— at 400 V rated value355 kW
— at 500 V rated value400 kW
— at 690 V rated value600 kW
— at 230 V rated value160 kW
— at 400 V rated value315 kW
— at 690 V rated value560 kW
up to 400 V for current peak value n=20 rated value338 kVA
up to 690 V for current peak value n=20 rated value586 kVA
up to 400 V for current peak value n=30 rated value226 kVA
up to 690 V for current peak value n=30 rated value390 kVA
thermal short-time current limited to 10 s5 040 A
power loss [W] at AC-3 at 400 V for rated value of the operational current per conductor45 W
power loss [W] at AC-3e at 400 V for rated value of the operational current per conductor35 W
no-load switching frequency at AC2 000 1/h
at AC-1 maximum700 1/h
— at 400 V maximum500 1/h
— at 690 V maximum500 1/h
at AC-2 at AC-3 maximum200 1/h
at AC-2 at AC-3e maximum200 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC
at 50 Hz rated value110 ... 120 V
at 60 Hz rated value110 ... 120 V
at 50 Hz0.8 ... 1.1
at 60 Hz0.8 ... 1.1
at 50 Hz1 000 V·A
at 60 Hz1 000 V·A
at 50 Hz1
at 60 Hz1
at 50 Hz11 V·A
at 60 Hz11 V·A
at 50 Hz1
at 60 Hz1
at AC35 ... 90 ms
at AC65 ... 90 ms
arcing time10 ... 15 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
attachable3
instantaneous contact3
attachable3
instantaneous contact3
operational current at AC-12 maximum10 A
at 230 V rated value5.6 A
at 400 V rated value3.6 A
at 500 V rated value2.5 A
at 690 V rated value2.3 A
operational current at DC-12 at 440 V rated value0.33 A
at 24 V rated value10 A
at 48 V rated value10 A
at 110 V rated value3.2 A
at 125 V rated value2.5 A
at 220 V rated value0.9 A
at 600 V rated value0.22 A
at 24 V rated value10 A
at 48 V rated value5 A
at 110 V rated value1.14 A
at 125 V rated value0.98 A
at 220 V rated value0.48 A
at 600 V rated value0.07 A
contact reliability of auxiliary contactsone incorrect switching operation of 100 million switching operations (17 V, 5 mA)
UL/CSA ratings
at 480 V rated value630 A
at 600 V rated value630 A
— at 200/208 V rated value231 hp
— at 220/230 V rated value266 hp
— at 460/480 V rated value530 hp
— at 575/600 V rated value664 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
— with type of coordination 1 requiredgG: 1000 A (690 V, 100 kA)
— with type of coordination 2 requiredgG: 500 A (690 V, 100 kA), aM: 630 A (690 V, 50 kA), BS88: 500 A (415 V, 50 kA)
for short-circuit protection of the auxiliary switch requiredfuse gG: 10 A
Installation/ mounting/ dimensions
mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
fastening method side-by-side mountingYes
fastening methodscrew fixing
height276 mm
width230 mm
depth237 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
— forwards20 mm
— upwards10 mm
— at the side10 mm
— downwards10 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
Connections/ Terminals
for main current circuitConnection bar
for auxiliary and control circuitscrew-type terminals
at contactor for auxiliary contactsScrew-type terminals
width of connection bar30 mm
thickness of connection bar6 mm
diameter of holes11 mm
number of holes1
stranded70 ... 240 mm²
finely stranded with core end processing50 ... 240 mm²
finely stranded with core end processing240 ... 50 mm²
solid or stranded0.5 ... 2.5 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
— solid2x (0.5 ... 1.0 mm²), 2x (1.0 ... 2.5 mm²)
— finely stranded with core end processing2x (0.5 ... 1.0 mm²), 2x (0.75 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (18 ... 12)
AWG number as coded connectable conductor cross section for main contacts500
AWG number as coded connectable conductor cross section for auxiliary contacts18 ... 12
Safety related data
mirror contact according to IEC 60947-4-1Yes; One NC contact each must be connected in series for the right and left auxiliary switch block respectively
positively driven operation according to IEC 60947-5-1No
suitable for safety functionYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP00

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
View Details

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

MXS-AS16L
SMC MXS-AS16L
View Details

SMC

MXS-AS16L

MFR #MXS-AS16L

SKU #YLSAP0XXFGFSWY6

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
View Details

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

BC8M12
Brush Research Mfg BC8M12
View Details

Brush Research Mfg

BC8M12

MFR #BC8M12

SKU #YLSA0P5BE6ZJCIW

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

Related Searches

Siemens 3TF6833-1QG7-ZA02 priceSiemens 3TF6833-1QG7-ZA02 quotebuy Siemens 3TF6833-1QG7-ZA023TF6833-1QG7-ZA02 price3TF6833-1QG7-ZA02 stock availabilitySiemens spare partsSiemens 3TF6833-1QG7-ZA02 equivalentSiemens 3TF6833-1QG7-ZA02 specifications