product brand nameSIRIUS
product categorySafety relays
product designationSensor extension
product type designation3SK1
Product Function
product function parameterizablesensor floating / sensor non-floating, monitored start-up / automatic start, 1-channel / 2-channel sensor connection, cross-circuit detection, startup testing, antivalent sensors, 2-hand switches
automatic startYes
light barrier monitoringYes
protective door monitoringYes
magnetically operated switch monitoring NC-NOYes
magnetically operated switch monitoring NC-NCYes
laser scanner monitoringYes
light array monitoringYes
EMERGENCY OFF functionYes
monitored start-upYes
pressure-sensitive mat monitoringNo
product feature cross-circuit-proofYes
suitability for interaction press controlNo
monitoring of floating sensorsYes
monitoring of non-floating sensorsYes
position switch monitoringYes
EMERGENCY-OFF circuit monitoringYes
opto-electronic protection device monitoringYes
magnetically operated switch monitoringYes
safety-related circuitsYes
General technical data
certificate of suitability UL approvalYes
product feature protective coating on printed-circuit boardNo
power loss [W] maximum1.2 W
insulation voltage rated value50 V
degree of pollution3
overvoltage category3
surge voltage resistance rated value800 V
protection class IP of the enclosureIP20
shock resistance10 g / 11 ms
vibration resistance according to IEC 60068-2-65 ... 500 Hz: 0.75 mm
reference code according to IEC 81346-2F
Substance Prohibitance (day/month/year)11/05/2012
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1
Net Weight0.127 kg
Ambient conditions
installation altitude at height above sea level maximum4 000 m
noteDerating, see Product Notification 109792701
during operation-25 ... +60 °C
during storage-40 ... +80 °C
relative humidity during operation10 ... 95 %
air pressure according to SN 31205900 ... 1 060 hPa
Electromagnetic compatibility
installation environment regarding EMCThis product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.
EMC emitted interferenceIEC 60947-5-1, Class A
Safety related data
product function suitable for safety functionYes
safe stateSafety outputs switched off
test wear-related service life necessaryNo
function test interval maximum1 a
diagnostics test interval by internal test function maximum600 s
stop category according to IEC 60204-10
IEC 62061
SIL Claim Limit (subsystem) according to EN 620613
according to IEC 62061SIL 3
at single-channel evaluation according to IEC 620611
at 2-channel evaluation according to IEC 620613
1E-9 1/h
0.000000001 1/h
ISO 13849
category according to EN ISO 13849-14
according to ISO 13849-1PL e
at single-channel evaluation according to ISO 13849-1c
at 2-channel evaluation according to ISO 13849-1e
according to ISO 13849-14
at 2-channel evaluation according to ISO 13849-14
device type according to ISO 13849-11
IEC 61508
according to IEC 615083
at single-channel evaluation according to IEC 615081
at 2-channel evaluation according to IEC 615083
safety device type according to IEC 61508-2Type B
PFHD with high demand rate according to IEC 615081E-9 1/h
PFHD with high demand rate according to IEC 615080.000000001 1/h
1E-5
0.00001
Safe failure fraction (SFF)99 %
according to IEC 615081
at single-channel evaluation according to IEC 615080
at 2-channel evaluation according to IEC 615081
of service life according to IEC 6150820 a
for proof test interval or service life according to IEC 6150820 a
Electrical Safety
touch protection against electrical shockfinger-safe
Inputs
feedback inputNo
start inputYes
number of sensor inputs 1-channel or 2-channel1
Outputs
— for signaling function instantaneous contact0
— for signaling function delayed switching0
— safety-related instantaneous contact0
— safety-related delayed switching0
— for signaling function instantaneous contact0
— for signaling function delayed switching0
— safety-related instantaneous contact0
— safety-related delayed switching0
— delayed switching0
wire length between sensor and electronics evaluation device with Cu 1.5 mm² and 150 nF/km maximum4 000 m
Times
typical60 ms
at DC maximum60 ms
typical6 500 ms
maximum6 500 ms
typical60 ms
maximum60 ms
backslide delay time after opening of the safety circuits typical40 ms
recovery time after opening of the safety circuits typical30 ms
of the sensor input minimum60 ms
of the ON pushbutton input minimum0.15 s
Control circuit/ Control
type of voltage of the control supply voltageDC
control supply voltage at DC rated value24 V
initial value0.8
full-scale value1.2
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew and snap-on mounting
height100 mm
width17.5 mm
depth121.6 mm
with side-by-side mounting at the side0 mm
for grounded parts at the side5 mm
Connections/ Terminals
type of electrical connectionscrew terminal
solid1x (0.5 ... 2.5 mm²), 2x (1.0 ... 1.5 mm²)
finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
for AWG cables solid1x (20 ... 14), 2x (18 ... 16)
type of electrical connection plug-in socketNo