product brand nameSIRIUS
product categoryHybrid switching devices
product designationSoft starter
product type designation3RW52
of standard HMI module usable3RW5980-0HS00
of high feature HMI module usable3RW5980-0HF00
of communication module PROFINET standard usable3RW5980-0CS00
of communication module PROFIBUS usable3RW5980-0CP00
of communication module Modbus TCP usable3RW5980-0CT00
of communication module Modbus RTU usable3RW5980-0CR00
of communication module Ethernet/IP3RW5980-0CE00
of circuit breaker usable at 400 V3VA2440-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
of circuit breaker usable at 500 V3VA2440-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
of circuit breaker usable at 400 V at inside-delta circuit3VA2580-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
of circuit breaker usable at 500 V at inside-delta circuit3VA2580-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
of the gG fuse usable up to 690 V2x3NA3365-6; Type of coordination 1, Iq = 65 kA
of the gG fuse usable at inside-delta circuit up to 500 V2x3NA3365-6; Type of coordination 1, Iq = 65 kA
of full range R fuse link for semiconductor protection usable up to 690 V3NE1334-2; Type of coordination 2, Iq = 65 kA
of back-up R fuse link for semiconductor protection usable up to 690 V3NE3336; Type of coordination 2, Iq = 65 kA
General technical data
starting voltage [%]30 ... 100 %
stopping voltage [%]50 %; non-adjustable
start-up ramp time of soft starter0 ... 20 s
current limiting value [%] adjustable130 ... 700 %
CE markingYes
UL approvalYes
CSA approvalYes
HMI-High FeatureNo
is supported HMI-StandardYes
is supported HMI-High FeatureYes
product feature integrated bypass contact systemYes
number of controlled phases3
for main current circuit100 ms
for control circuit100 ms
insulation voltage rated value600 V
degree of pollution3, acc. to IEC 60947-4-2
impulse voltage rated value6 kV
blocking voltage of the thyristor maximum1 600 V
service factor1
surge voltage resistance rated value6 kV
between main and auxiliary circuit600 V
shock resistance15 g / 11 ms, from 12 g / 11 ms with potential contact lifting
vibration resistance15 mm to 6 Hz; 2 g to 500 Hz
utilization category according to IEC 60947-4-2AC 53a
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)02/15/2018
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1 Dibutylbis(pentane-2,4-dionato-O,O')tin CAS-No. 22673-19-4
Net Weight9.757 kg
ramp-up (soft starting)Yes
soft stoppingYes
Soft TorqueYes
adjustable current limitationYes
pump stopYes
intrinsic device protectionYes
motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
evaluation of thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
inside-delta circuitYes
auto-RESETYes
manual RESETYes
remote resetYes; By turning off the control supply voltage
communication functionYes
operating measured value displayYes; Only in conjunction with special accessories
error logbookYes; Only in conjunction with special accessories
via software parameterizableNo
via software configurableYes
PROFIenergyYes; in connection with the PROFINET Standard communication module
firmware updateYes
removable terminal for control circuitYes
torque controlNo
analog outputNo
Power Electronics
at 40 °C rated value370 A
at 50 °C rated value328 A
at 60 °C rated value300 A
at 40 °C rated value641 A
at 50 °C rated value568 A
at 60 °C rated value519 A
rated value200 ... 600 V
at inside-delta circuit rated value200 ... 600 V
relative negative tolerance of the operating voltage-15 %
relative positive tolerance of the operating voltage10 %
relative negative tolerance of the operating voltage at inside-delta circuit-15 %
relative positive tolerance of the operating voltage at inside-delta circuit10 %
at 230 V at 40 °C rated value110 kW
at 230 V at inside-delta circuit at 40 °C rated value200 kW
at 400 V at 40 °C rated value200 kW
at 400 V at inside-delta circuit at 40 °C rated value355 kW
at 500 V at 40 °C rated value250 kW
at 500 V at inside-delta circuit at 40 °C rated value450 kW
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
relative negative tolerance of the operating frequency-10 %
relative positive tolerance of the operating frequency10 %
at rotary coding switch on switch position 1160 A
at rotary coding switch on switch position 2174 A
at rotary coding switch on switch position 3188 A
at rotary coding switch on switch position 4202 A
at rotary coding switch on switch position 5216 A
at rotary coding switch on switch position 6230 A
at rotary coding switch on switch position 7244 A
at rotary coding switch on switch position 8258 A
at rotary coding switch on switch position 9272 A
at rotary coding switch on switch position 10286 A
at rotary coding switch on switch position 11300 A
at rotary coding switch on switch position 12314 A
at rotary coding switch on switch position 13328 A
at rotary coding switch on switch position 14342 A
at rotary coding switch on switch position 15356 A
at rotary coding switch on switch position 16370 A
minimum160 A
for inside-delta circuit at rotary coding switch on switch position 1277 A
for inside-delta circuit at rotary coding switch on switch position 2301 A
for inside-delta circuit at rotary coding switch on switch position 3326 A
for inside-delta circuit at rotary coding switch on switch position 4350 A
for inside-delta circuit at rotary coding switch on switch position 5374 A
for inside-delta circuit at rotary coding switch on switch position 6398 A
for inside-delta circuit at rotary coding switch on switch position 7423 A
for inside-delta circuit at rotary coding switch on switch position 8447 A
for inside-delta circuit at rotary coding switch on switch position 9471 A
for inside-delta circuit at rotary coding switch on switch position 10495 A
for inside-delta circuit at rotary coding switch on switch position 11520 A
for inside-delta circuit at rotary coding switch on switch position 12544 A
for inside-delta circuit at rotary coding switch on switch position 13568 A
for inside-delta circuit at rotary coding switch on switch position 14592 A
for inside-delta circuit at rotary coding switch on switch position 15617 A
for inside-delta circuit at rotary coding switch on switch position 16641 A
at inside-delta circuit minimum277 A
minimum load [%]15 %; Relative to smallest settable Ie
at 40 °C after startup123 W
at 50 °C after startup110 W
at 60 °C after startup102 W
at 40 °C during startup5 575 W
at 50 °C during startup4 706 W
at 60 °C during startup4 157 W
Control circuit/ Control
type of voltage of the control supply voltageAC
at 50 Hz110 ... 250 V
at 60 Hz110 ... 250 V
relative negative tolerance of the control supply voltage at AC at 50 Hz-15 %
relative positive tolerance of the control supply voltage at AC at 50 Hz10 %
relative negative tolerance of the control supply voltage at AC at 60 Hz-15 %
relative positive tolerance of the control supply voltage at AC at 60 Hz10 %
control supply voltage frequency50 ... 60 Hz
relative negative tolerance of the control supply voltage frequency-10 %
relative positive tolerance of the control supply voltage frequency10 %
control supply current in standby mode rated value30 mA
holding current in bypass operation rated value100 mA
inrush current by closing the bypass contacts maximum2.2 A
inrush current peak at application of control supply voltage maximum12.2 A
duration of inrush current peak at application of control supply voltage2.2 ms
design of the overvoltage protectionVaristor
design of short-circuit protection for control circuit4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply
Inputs/ Outputs
number of digital inputs1
number of digital outputs3
not parameterizable2
digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)
number of analog outputs0
at AC-15 at 250 V rated value3 A
at DC-13 at 24 V rated value1 A
Installation/ mounting/ dimensions
mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
fastening methodscrew fixing
height393 mm
width210 mm
depth203 mm
forwards10 mm
backwards0 mm
upwards100 mm
downwards75 mm
at the side5 mm
weight without packaging9.9 kg
Connections/ Terminals
for main current circuitbusbar connection
for control circuitscrew-type terminals
width of connection bar maximum45 mm
with conductor cross-section = 0.5 mm² maximum50 m
with conductor cross-section = 1.5 mm² maximum150 m
with conductor cross-section = 2.5 mm² maximum250 m
for DIN cable lug for main contacts stranded2x (50 ... 240 mm²)
for DIN cable lug for main contacts finely stranded2x (70 ... 240 mm²)
for control circuit solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
for control circuit finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
for AWG cables for control circuit solid1x (20 ... 12), 2x (20 ... 14)
between soft starter and motor maximum800 m
at the digital inputs at AC maximum100 m
for main contacts with screw-type terminals14 ... 24 N·m
for auxiliary and control contacts with screw-type terminals0.8 ... 1.2 N·m
for main contacts with screw-type terminals124 ... 210 lbf·in
for auxiliary and control contacts with screw-type terminals7 ... 10.3 lbf·in
Ambient conditions
installation altitude at height above sea level maximum5 000 m
during operation-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
during storage and transport-40 ... +80 °C
during operation according to IEC 607213K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
during storage according to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
Electromagnetic compatibility
EMC emitted interferenceacc. to IEC 60947-4-2: Class A
Communication/ Protocol
PROFINET standardYes
EtherNet/IPYes
Modbus RTUYes
Modbus TCPYes
PROFIBUSYes
UL/CSA ratings
— usable for Standard Faults up to 575/600 V according to ULType: Class J / L, max. 1200 A; Iq = 18 kA
— usable for High Faults up to 575/600 V according to ULType: Class J / L, max. 1200 A; Iq = 100 kA
— usable for Standard Faults at inside-delta circuit up to 575/600 V according to ULType: Class J / L, max. 1200 A; Iq = 18 kA
— usable for High Faults at inside-delta circuit up to 575/600 V according to ULType: Class J / L, max. 1200 A; Iq = 100 kA
at 200/208 V at 50 °C rated value100 hp
at 220/230 V at 50 °C rated value125 hp
at 460/480 V at 50 °C rated value250 hp
at 575/600 V at 50 °C rated value300 hp
at 200/208 V at inside-delta circuit at 50 °C rated value200 hp
at 220/230 V at inside-delta circuit at 50 °C rated value200 hp
at 460/480 V at inside-delta circuit at 50 °C rated value450 hp
at 575/600 V at inside-delta circuit at 50 °C rated value600 hp
contact rating of auxiliary contacts according to ULR300-B300
Electrical Safety
protection class IP on the front according to IEC 60529IP00; IP20 with cover
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with cover
Approvals Certificates
global warming potential [CO2 eq] / during manufacturing84.2 kg
global warming potential [CO2 eq] / during sales2.81 kg
global warming potential [CO2 eq] / during operation721 kg
global warming potential [CO2 eq] / after end of life-21.8 kg
global warming potential [CO2 eq] / total786 kg
Product information
EAN4047621038018
Product family3RW52 soft starters
Life cycle statusActive
Commodity code85371098
Delivery and logistics
Country of originCzech Republic
Standard delivery time3 Day/Days
ReturnableYes
Net weight9.757 Kg
Packaging dimensions (L x W x H)501 x 325 x 330 MM
Standard package quantity1 Piece
Minimum order quantity1
Dangerous goodsNo
Export control regulationsAL : N / ECCN : N
Environment and compliance
RoHS conformitySince: 15-02-18
WEEE category4
REACH informationLead CAS-No. 7439-92-1 > 0,1 % (w / w)
SCIP numberc4e0feb3-6d92-4a32-88f2-d3556b69e3c2
Siemens catalog
Product group4981
Catalog IDCC-IC10
Group codeR711
Product classStraightforward, can be reused over the short term