Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3RW5225-3TC05

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3RW5225-3TC05

SIRIUS soft starter 200-600 V 63 A, 24 V AC/DC spring-type terminals Thermistor input

SiemensMFR # 3RW5225-3TC05SKU # YLSIJIMXE6XLJ82
product brand nameSIRIUS
product categoryHybrid switching devices
product designationSoft starter
product type designation3RW52
of standard HMI module usable3RW5980-0HS00
of high feature HMI module usable3RW5980-0HF00
Share

About This Product

SIRIUS soft starter 200-600 V 63 A, 24 V AC/DC spring-type terminals Thermistor input

Siemens 3RW5225-3TC05

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product categoryHybrid switching devices
product designationSoft starter
product type designation3RW52
of standard HMI module usable3RW5980-0HS00
of high feature HMI module usable3RW5980-0HF00
of communication module PROFINET standard usable3RW5980-0CS00
of communication module PROFIBUS usable3RW5980-0CP00
of communication module Modbus TCP usable3RW5980-0CT00
of communication module Modbus RTU usable3RW5980-0CR00
of communication module Ethernet/IP3RW5980-0CE00
of circuit breaker usable at 400 V3VA2163-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
of circuit breaker usable at 500 V3VA2163-7MN32-0AA0; Type of coordination 1, Iq = 20 kA, CLASS 10
of circuit breaker usable at 400 V at inside-delta circuit3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
of circuit breaker usable at 500 V at inside-delta circuit3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 20 kA, CLASS 10
of the gG fuse usable up to 690 V3NA3830-6; Type of coordination 1, Iq = 65 kA
of the gG fuse usable at inside-delta circuit up to 500 V3NA3830-6; Type of coordination 1, Iq = 65 kA
of full range R fuse link for semiconductor protection usable up to 690 V3NE1022-0; Type of coordination 2, Iq = 65 kA
of back-up R fuse link for semiconductor protection usable up to 690 V3NE8024-1; Type of coordination 2, Iq = 65 kA
General technical data
starting voltage [%]30 ... 100 %
stopping voltage [%]50 %; non-adjustable
start-up ramp time of soft starter0 ... 20 s
current limiting value [%] adjustable130 ... 700 %
CE markingYes
UL approvalYes
CSA approvalYes
HMI-High FeatureNo
is supported HMI-StandardYes
is supported HMI-High FeatureYes
product feature integrated bypass contact systemYes
number of controlled phases3
for main current circuit100 ms
for control circuit100 ms
insulation voltage rated value600 V
degree of pollution3, acc. to IEC 60947-4-2
impulse voltage rated value6 kV
blocking voltage of the thyristor maximum1 800 V
service factor1
surge voltage resistance rated value6 kV
between main and auxiliary circuit600 V
shock resistance15 g / 11 ms, from 12 g / 11 ms with potential contact lifting
vibration resistance15 mm to 6 Hz; 2 g to 500 Hz
utilization category according to IEC 60947-4-2AC 53a
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)02/15/2018
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1 Dibutylbis(pentane-2,4-dionato-O,O')tin CAS-No. 22673-19-4 Diboron trioxide CAS-No. 1303-86-2 Perfluorobutane sulfonic acid (PFBS) and its salts CAS-No. -
Net Weight3.628 kg
ramp-up (soft starting)Yes
soft stoppingYes
Soft TorqueYes
adjustable current limitationYes
pump stopYes
intrinsic device protectionYes
motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
evaluation of thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
inside-delta circuitYes
auto-RESETYes
manual RESETYes
remote resetYes; By turning off the control supply voltage
communication functionYes
operating measured value displayYes; Only in conjunction with special accessories
error logbookYes; Only in conjunction with special accessories
via software parameterizableNo
via software configurableYes
PROFIenergyYes; in connection with the PROFINET Standard communication module
firmware updateYes
removable terminal for control circuitYes
torque controlNo
analog outputNo
Power Electronics
at 40 °C rated value63 A
at 50 °C rated value55.5 A
at 60 °C rated value50.5 A
at 40 °C rated value109 A
at 50 °C rated value96 A
at 60 °C rated value87.5 A
rated value200 ... 600 V
at inside-delta circuit rated value200 ... 600 V
relative negative tolerance of the operating voltage-15 %
relative positive tolerance of the operating voltage10 %
relative negative tolerance of the operating voltage at inside-delta circuit-15 %
relative positive tolerance of the operating voltage at inside-delta circuit10 %
at 230 V at 40 °C rated value18.5 kW
at 230 V at inside-delta circuit at 40 °C rated value30 kW
at 400 V at 40 °C rated value30 kW
at 400 V at inside-delta circuit at 40 °C rated value55 kW
at 500 V at 40 °C rated value37 kW
at 500 V at inside-delta circuit at 40 °C rated value55 kW
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
relative negative tolerance of the operating frequency-10 %
relative positive tolerance of the operating frequency10 %
at rotary coding switch on switch position 125.5 A
at rotary coding switch on switch position 228 A
at rotary coding switch on switch position 330.5 A
at rotary coding switch on switch position 433 A
at rotary coding switch on switch position 535.5 A
at rotary coding switch on switch position 638 A
at rotary coding switch on switch position 740.5 A
at rotary coding switch on switch position 843 A
at rotary coding switch on switch position 945.5 A
at rotary coding switch on switch position 1048 A
at rotary coding switch on switch position 1150.5 A
at rotary coding switch on switch position 1253 A
at rotary coding switch on switch position 1355.5 A
at rotary coding switch on switch position 1458 A
at rotary coding switch on switch position 1560.5 A
at rotary coding switch on switch position 1663 A
minimum25.5 A
for inside-delta circuit at rotary coding switch on switch position 144.2 A
for inside-delta circuit at rotary coding switch on switch position 248.5 A
for inside-delta circuit at rotary coding switch on switch position 352.8 A
for inside-delta circuit at rotary coding switch on switch position 457.2 A
for inside-delta circuit at rotary coding switch on switch position 561.5 A
for inside-delta circuit at rotary coding switch on switch position 665.8 A
for inside-delta circuit at rotary coding switch on switch position 770.1 A
for inside-delta circuit at rotary coding switch on switch position 874.5 A
for inside-delta circuit at rotary coding switch on switch position 978.8 A
for inside-delta circuit at rotary coding switch on switch position 1083.1 A
for inside-delta circuit at rotary coding switch on switch position 1187.5 A
for inside-delta circuit at rotary coding switch on switch position 1291.8 A
for inside-delta circuit at rotary coding switch on switch position 1396.1 A
for inside-delta circuit at rotary coding switch on switch position 14100 A
for inside-delta circuit at rotary coding switch on switch position 15105 A
for inside-delta circuit at rotary coding switch on switch position 16109 A
at inside-delta circuit minimum44.2 A
minimum load [%]15 %; Relative to smallest settable Ie
at 40 °C after startup31 W
at 50 °C after startup29 W
at 60 °C after startup27 W
at 40 °C during startup882 W
at 50 °C during startup744 W
at 60 °C during startup659 W
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
at 50 Hz rated value24 V
at 60 Hz rated value24 V
relative negative tolerance of the control supply voltage at AC at 50 Hz-20 %
relative positive tolerance of the control supply voltage at AC at 50 Hz20 %
relative negative tolerance of the control supply voltage at AC at 60 Hz-20 %
relative positive tolerance of the control supply voltage at AC at 60 Hz20 %
control supply voltage frequency50 ... 60 Hz
relative negative tolerance of the control supply voltage frequency-10 %
relative positive tolerance of the control supply voltage frequency10 %
control supply voltage at DC rated value24 V
relative negative tolerance of the control supply voltage at DC-20 %
relative positive tolerance of the control supply voltage at DC20 %
control supply current in standby mode rated value160 mA
holding current in bypass operation rated value380 mA
inrush current by closing the bypass contacts maximum7.6 A
inrush current peak at application of control supply voltage maximum3.3 A
duration of inrush current peak at application of control supply voltage12.1 ms
design of the overvoltage protectionVaristor
design of short-circuit protection for control circuit4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply
Inputs/ Outputs
number of digital inputs1
number of digital outputs3
not parameterizable2
digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)
number of analog outputs0
at AC-15 at 250 V rated value3 A
at DC-13 at 24 V rated value1 A
Installation/ mounting/ dimensions
mounting position+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface
fastening methodscrew fixing
height306 mm
width185 mm
depth203 mm
forwards10 mm
backwards0 mm
upwards100 mm
downwards75 mm
at the side5 mm
weight without packaging5.6 kg
Connections/ Terminals
for main current circuitbox terminal
for control circuitspring-loaded terminals
width of connection bar maximum25 mm
with conductor cross-section = 0.5 mm² maximum50 m
with conductor cross-section = 1.5 mm² maximum150 m
with conductor cross-section = 2.5 mm² maximum250 m
using the front clamping point solid1x (2.5 ... 16 mm²)
using the front clamping point finely stranded with core end processing1x (2.5 ... 50 mm²)
using the front clamping point stranded1x (10 ... 70 mm²)
using the back clamping point solid1x (2.5 ... 16 mm²)
r box terminal using the back clamping point1x (10 ... 2/0)
using both clamping points solid2x (2.5 ... 16 mm²)
using both clamping points finely stranded with core end processing2x (2.5 ... 35 mm²)
using both clamping points stranded2x (6 ... 16 mm²), 2x (10 ... 50 mm²)
using the back clamping point finely stranded with core end processing1x (2.5 ... 50 mm²)
using the back clamping point stranded1x (10 ... 70 mm²)
for control circuit solid2x (0.25 ... 1.5 mm²)
for control circuit finely stranded with core end processing2x (0.25 ... 1.5 mm²)
for AWG cables for control circuit solid2x (24 ... 16)
for AWG cables for control circuit finely stranded with core end processing2x (24 ... 16)
between soft starter and motor maximum800 m
at the digital inputs at AC maximum100 m
at the digital inputs at DC maximum1 000 m
for main contacts with screw-type terminals4.5 ... 6 N·m
for auxiliary and control contacts with screw-type terminals0.8 ... 1.2 N·m
for main contacts with screw-type terminals40 ... 53 lbf·in
for auxiliary and control contacts with screw-type terminals7 ... 10.3 lbf·in
Ambient conditions
installation altitude at height above sea level maximum5 000 m
during operation-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
during storage and transport-40 ... +80 °C
during operation according to IEC 607213K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
during storage according to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
Electromagnetic compatibility
EMC emitted interferenceacc. to IEC 60947-4-2: Class A
Communication/ Protocol
PROFINET standardYes
EtherNet/IPYes
Modbus RTUYes
Modbus TCPYes
PROFIBUSYes
UL/CSA ratings
— at 460/480 V according to ULSiemens type: 3RV2742, max. 70 A or 3VA51, max. 125 A; Iq = 10 kA
— 60/480 V according to ULSiemens type: 3VA51, max. 125 A; Iq max = 65 kA
— at 460/480 V at inside-delta circuit according to ULSiemens type: 3VA51, max. 125 A; Iq = 10 kA
— 60/480 V at inside-delta circuit according to ULSiemens type: 3VA51, max. 125 A; Iq max = 65 kA
— at 575/600 V according to ULSiemens type: 3RV2742, max. 70 A or 3VA51, max. 125 A; Iq = 10 kA
— at 575/600 V at inside-delta circuit according to ULSiemens type: 3VA51, max. 125 A; Iq = 10 kA
— usable for Standard Faults up to 575/600 V according to ULType: Class RK5 / K5, max. 200 A; Iq = 10 kA
— usable for High Faults up to 575/600 V according to ULType: Class J / L, max. 225 A; Iq = 100 kA
— usable for Standard Faults at inside-delta circuit up to 575/600 V according to ULType: Class RK5 / K5, max. 200 A; Iq = 10 kA
— usable for High Faults at inside-delta circuit up to 575/600 V according to ULType: Class J / L, max. 225 A; Iq = 100 kA
at 200/208 V at 50 °C rated value15 hp
at 220/230 V at 50 °C rated value20 hp
at 460/480 V at 50 °C rated value40 hp
at 575/600 V at 50 °C rated value50 hp
at 200/208 V at inside-delta circuit at 50 °C rated value30 hp
at 220/230 V at inside-delta circuit at 50 °C rated value30 hp
at 460/480 V at inside-delta circuit at 50 °C rated value75 hp
at 575/600 V at inside-delta circuit at 50 °C rated value75 hp
contact rating of auxiliary contacts according to ULR300-B300
Electrical Safety
protection class IP on the front according to IEC 60529IP00; IP20 with cover
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with cover
Approvals Certificates
global warming potential [CO2 eq] / during manufacturing67.7 kg
global warming potential [CO2 eq] / during sales1.84 kg
global warming potential [CO2 eq] / during operation242 kg
global warming potential [CO2 eq] / after end of life-15.7 kg
global warming potential [CO2 eq] / total296 kg

Accessories 23

Genuine accessories that can be used with the Siemens 3RW5225-3TC05 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
3RW5980-0CP00Aksesuar · Communication modules
3RW5980-0CR00Aksesuar · Communication modules
3RW5980-0CS00Aksesuar · Communication modules
3RW5980-0CT00Aksesuar · Communication modules
3RW5980-0CE00Aksesuar · Communication modules
3RW5980-0HF00Aksesuar · HMI modules
3RW5980-0HS00Aksesuar · HMI modules
3RT2900-1SB20Aksesuar · Miscellaneous accessories · labeling plates
3RW5983-0TC20Aksesuar · Terminal covers
3RW5982-0TB00Yedek parça · Terminals
3RW5953-0VY00Yedek parça · Transport packages
3RW5980-2TR00Yedek parça · Terminals
3RW5953-0GB00Yedek parça · Enclosure components
3RW5950-0GD20Yedek parça · Enclosure components
3RW5923-0PY05Yedek parça · Printed circuit boards
3RW5920-1UT00Yedek parça · Control units
3RW5953-0BY00Yedek parça · Bypass units
3RW5952-0SH05Yedek parça · Power semiconductor modules
3RW5950-0GL20Yedek parça · Enclosure components
3VA2163-7MN32-0AA0Seçmeli zorunlu ürün
3NA3830-6Seçmeli zorunlu ürün
3NE8024-1Seçmeli zorunlu ürün
3NE1022-0Seçmeli zorunlu ürün

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

MTS32-150M
SMC MTS32-150M
View Details

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

CG5EN50SV-150
SMC CG5EN50SV-150
View Details

SMC

CG5EN50SV-150

MFR #CG5EN50SV-150

SKU #YLST11TLVYPVP7H

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
View Details

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

Related Searches

Siemens 3RW5225-3TC05 priceSiemens 3RW5225-3TC05 quotebuy Siemens 3RW5225-3TC053RW5225-3TC05 price3RW5225-3TC05 stock availabilitySiemens spare partsSiemens 3RW5225-3TC05 equivalentSiemens 3RW5225-3TC05 specifications