Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3RW5214-3AC14

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3RW5214-3AC14

SIRIUS soft starter 200-480 V 18 A, 110-250 V AC spring-type terminals Analog output

SiemensMFR # 3RW5214-3AC14SKU # YLSEBQ14PXCEROB
product brand nameSIRIUS
product categoryHybrid switching devices
product designationSoft starter
product type designation3RW52
of standard HMI module usable3RW5980-0HS00
of high feature HMI module usable3RW5980-0HF00
Share

About This Product

SIRIUS soft starter 200-480 V 18 A, 110-250 V AC spring-type terminals Analog output

Siemens 3RW5214-3AC14

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product categoryHybrid switching devices
product designationSoft starter
product type designation3RW52
of standard HMI module usable3RW5980-0HS00
of high feature HMI module usable3RW5980-0HF00
of communication module PROFINET standard usable3RW5980-0CS00
of communication module PROFIBUS usable3RW5980-0CP00
of communication module Modbus TCP usable3RW5980-0CT00
of communication module Modbus RTU usable3RW5980-0CR00
of communication module Ethernet/IP3RW5980-0CE00
of circuit breaker usable at 400 V3RV2032-4DA10; Type of coordination 1, Iq = 65 kA, CLASS 10
of circuit breaker usable at 500 V3RV2032-4DA10; Type of coordination 1, Iq = 15 kA, CLASS 10
of circuit breaker usable at 400 V at inside-delta circuit3RV2032-4EA10; Type of coordination 1, Iq = 65 kA, CLASS 10
of circuit breaker usable at 500 V at inside-delta circuit3RV2032-4EA10; Type of coordination 1, Iq = 15 kA, CLASS 10
of the gG fuse usable up to 690 V3NA3820-6; Type of coordination 1, Iq = 65 kA
of the gG fuse usable at inside-delta circuit up to 500 V3NA3820-6; Type of coordination 1, Iq = 65 kA
of full range R fuse link for semiconductor protection usable up to 690 V3NE1802-0; Type of coordination 2, Iq = 65 kA
of back-up R fuse link for semiconductor protection usable up to 690 V3NE8020-1; Type of coordination 2, Iq = 65 kA
General technical data
starting voltage [%]30 ... 100 %
stopping voltage [%]50 %; non-adjustable
start-up ramp time of soft starter0 ... 20 s
current limiting value [%] adjustable130 ... 700 %
CE markingYes
UL approvalYes
CSA approvalYes
HMI-High FeatureNo
is supported HMI-StandardYes
is supported HMI-High FeatureYes
product feature integrated bypass contact systemYes
number of controlled phases3
for main current circuit100 ms
for control circuit100 ms
insulation voltage rated value600 V
degree of pollution3, acc. to IEC 60947-4-2
impulse voltage rated value6 kV
blocking voltage of the thyristor maximum1 600 V
service factor1
surge voltage resistance rated value6 kV
between main and auxiliary circuit600 V
shock resistance15 g / 11 ms, from 12 g / 11 ms with potential contact lifting
vibration resistance15 mm to 6 Hz; 2 g to 500 Hz
utilization category according to IEC 60947-4-2AC 53a
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)02/15/2018
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1 Dibutylbis(pentane-2,4-dionato-O,O')tin CAS-No. 22673-19-4 Diboron trioxide CAS-No. 1303-86-2
Net Weight1.645 kg
ramp-up (soft starting)Yes
soft stoppingYes
Soft TorqueYes
adjustable current limitationYes
pump stopYes
intrinsic device protectionYes
motor overload protectionYes; Electronic motor overload protection
evaluation of thermistor motor protectionNo
inside-delta circuitYes
auto-RESETYes
manual RESETYes
remote resetYes; By turning off the control supply voltage
communication functionYes
operating measured value displayYes; Only in conjunction with special accessories
error logbookYes; Only in conjunction with special accessories
via software parameterizableNo
via software configurableYes
PROFIenergyYes; in connection with the PROFINET Standard communication module
firmware updateYes
removable terminal for control circuitYes
torque controlNo
analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Power Electronics
at 40 °C rated value18 A
at 50 °C rated value15.9 A
at 60 °C rated value13.8 A
at 40 °C rated value31.5 A
at 50 °C rated value28 A
at 60 °C rated value23.9 A
rated value200 ... 480 V
at inside-delta circuit rated value200 ... 480 V
relative negative tolerance of the operating voltage-15 %
relative positive tolerance of the operating voltage10 %
relative negative tolerance of the operating voltage at inside-delta circuit-15 %
relative positive tolerance of the operating voltage at inside-delta circuit10 %
at 230 V at 40 °C rated value4 kW
at 230 V at inside-delta circuit at 40 °C rated value7.5 kW
at 400 V at 40 °C rated value7.5 kW
at 400 V at inside-delta circuit at 40 °C rated value15 kW
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
relative negative tolerance of the operating frequency-10 %
relative positive tolerance of the operating frequency10 %
at rotary coding switch on switch position 17.5 A
at rotary coding switch on switch position 28.2 A
at rotary coding switch on switch position 38.9 A
at rotary coding switch on switch position 49.6 A
at rotary coding switch on switch position 510.3 A
at rotary coding switch on switch position 611 A
at rotary coding switch on switch position 711.7 A
at rotary coding switch on switch position 812.4 A
at rotary coding switch on switch position 913.1 A
at rotary coding switch on switch position 1013.8 A
at rotary coding switch on switch position 1114.5 A
at rotary coding switch on switch position 1215.2 A
at rotary coding switch on switch position 1315.9 A
at rotary coding switch on switch position 1416.6 A
at rotary coding switch on switch position 1517.3 A
at rotary coding switch on switch position 1618 A
minimum7.5 A
for inside-delta circuit at rotary coding switch on switch position 113 A
for inside-delta circuit at rotary coding switch on switch position 214.2 A
for inside-delta circuit at rotary coding switch on switch position 315.4 A
for inside-delta circuit at rotary coding switch on switch position 416.6 A
for inside-delta circuit at rotary coding switch on switch position 517.8 A
for inside-delta circuit at rotary coding switch on switch position 619.1 A
for inside-delta circuit at rotary coding switch on switch position 720.3 A
for inside-delta circuit at rotary coding switch on switch position 821.5 A
for inside-delta circuit at rotary coding switch on switch position 922.7 A
for inside-delta circuit at rotary coding switch on switch position 1023.9 A
for inside-delta circuit at rotary coding switch on switch position 1125.1 A
for inside-delta circuit at rotary coding switch on switch position 1226.3 A
for inside-delta circuit at rotary coding switch on switch position 1327.5 A
for inside-delta circuit at rotary coding switch on switch position 1428.8 A
for inside-delta circuit at rotary coding switch on switch position 1530 A
for inside-delta circuit at rotary coding switch on switch position 1631.2 A
at inside-delta circuit minimum13 A
minimum load [%]15 %; Relative to smallest settable Ie
at 40 °C after startup17 W
at 50 °C after startup17 W
at 60 °C after startup16 W
at 40 °C during startup276 W
at 50 °C during startup241 W
at 60 °C during startup200 W
Control circuit/ Control
type of voltage of the control supply voltageAC
at 50 Hz110 ... 250 V
at 60 Hz110 ... 250 V
relative negative tolerance of the control supply voltage at AC at 50 Hz-15 %
relative positive tolerance of the control supply voltage at AC at 50 Hz10 %
relative negative tolerance of the control supply voltage at AC at 60 Hz-15 %
relative positive tolerance of the control supply voltage at AC at 60 Hz10 %
control supply voltage frequency50 ... 60 Hz
relative negative tolerance of the control supply voltage frequency-10 %
relative positive tolerance of the control supply voltage frequency10 %
control supply current in standby mode rated value30 mA
holding current in bypass operation rated value75 mA
inrush current by closing the bypass contacts maximum0.17 A
inrush current peak at application of control supply voltage maximum12.2 A
duration of inrush current peak at application of control supply voltage2.2 ms
design of the overvoltage protectionVaristor
design of short-circuit protection for control circuit4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply
Inputs/ Outputs
number of digital inputs1
number of digital outputs3
not parameterizable2
digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)
number of analog outputs1
at AC-15 at 250 V rated value3 A
at DC-13 at 24 V rated value1 A
Installation/ mounting/ dimensions
mounting position+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface
fastening methodscrew fixing
height275 mm
width170 mm
depth152 mm
forwards10 mm
backwards0 mm
upwards100 mm
downwards75 mm
at the side5 mm
weight without packaging2.1 kg
Connections/ Terminals
for main current circuitscrew-type terminals
for control circuitspring-loaded terminals
— solid2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
— finely stranded with core end processing2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)
for AWG cables for main current circuit solid2x (16 ... 12), 2x (14 ... 8)
for control circuit solid2x (0.25 ... 1.5 mm²)
for control circuit finely stranded with core end processing2x (0.25 ... 1.5 mm²)
for AWG cables for control circuit solid2x (24 ... 16)
for AWG cables for control circuit finely stranded with core end processing2x (24 ... 16)
between soft starter and motor maximum800 m
at the digital inputs at AC maximum100 m
for main contacts with screw-type terminals2 ... 2.5 N·m
for auxiliary and control contacts with screw-type terminals0.8 ... 1.2 N·m
for main contacts with screw-type terminals18 ... 22 lbf·in
for auxiliary and control contacts with screw-type terminals7 ... 10.3 lbf·in
Ambient conditions
installation altitude at height above sea level maximum5 000 m
during operation-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
during storage and transport-40 ... +80 °C
during operation according to IEC 607213K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
during storage according to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
Electromagnetic compatibility
EMC emitted interferenceacc. to IEC 60947-4-2: Class A
Communication/ Protocol
PROFINET standardYes
EtherNet/IPYes
Modbus RTUYes
Modbus TCPYes
PROFIBUSYes
UL/CSA ratings
— at 460/480 V according to ULSiemens type: 3RV2742, max. 60 A or 3VA51, max. 60 A; Iq = 5 kA
— 60/480 V according to ULSiemens type: 3RV2742, max. 30 A or 3VA51, max. 35 A; Iq max = 65 kA
— at 460/480 V at inside-delta circuit according to ULSiemens type: 3RV2742, max. 60 A or 3VA51, max. 60 A; Iq = 5 kA
— 60/480 V at inside-delta circuit according to ULSiemens type: 3VA51, max. 35 A; Iq max = 65 kA
— at 575/600 V according to ULSiemens type: 3RV2742, max. 60 A or 3VA51, max. 60 A; Iq = 5 kA
— at 575/600 V at inside-delta circuit according to ULSiemens type: 3RV2742, max. 60 A or 3VA51, max. 60 A; Iq = 5 kA
— usable for Standard Faults up to 575/600 V according to ULType: Class RK5 / K5, max. 70 A; Iq = 5 kA
— usable for High Faults up to 575/600 V according to ULType: Class J / L, max. 70 A; Iq = 100 kA
— usable for Standard Faults at inside-delta circuit up to 575/600 V according to ULType: Class RK5 / K5, max. 70 A; Iq = 5 kA
— usable for High Faults at inside-delta circuit up to 575/600 V according to ULType: Class J / L, max. 70 A; Iq = 100 kA
at 200/208 V at 50 °C rated value3 hp
at 220/230 V at 50 °C rated value5 hp
at 460/480 V at 50 °C rated value10 hp
at 200/208 V at inside-delta circuit at 50 °C rated value7.5 hp
at 220/230 V at inside-delta circuit at 50 °C rated value7.5 hp
at 460/480 V at inside-delta circuit at 50 °C rated value20 hp
contact rating of auxiliary contacts according to ULR300-B300
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Approvals Certificates
global warming potential [CO2 eq] / during manufacturing37.2 kg
global warming potential [CO2 eq] / during sales0.66 kg
global warming potential [CO2 eq] / during operation152 kg
global warming potential [CO2 eq] / after end of life-4.19 kg
global warming potential [CO2 eq] / total185 kg

Accessories 18

Genuine accessories that can be used with the Siemens 3RW5214-3AC14 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
3RW5980-0CP00Aksesuar · Communication modules
3RW5980-0CR00Aksesuar · Communication modules
3RW5980-0CS00Aksesuar · Communication modules
3RW5980-0CT00Aksesuar · Communication modules
3RW5980-0CE00Aksesuar · Communication modules
3RW5980-0HF00Aksesuar · HMI modules
3RW5980-0HS00Aksesuar · HMI modules
3RT2900-1SB20Aksesuar · Miscellaneous accessories · labeling plates
3RW5980-2TR00Yedek parça · Terminals
3RW5950-0GL20Yedek parça · Enclosure components
3RW5950-0GD20Yedek parça · Enclosure components
3RW5920-1UA10Yedek parça · Control units
3RW5921-0PB04Yedek parça · Printed circuit boards
3RW5951-0VY00Yedek parça · Transport packages
3RV2032-4DA10Seçmeli zorunlu ürün
3NA3820-6Seçmeli zorunlu ürün
3NE8020-1Seçmeli zorunlu ürün
3NE1802-0Seçmeli zorunlu ürün

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
View Details

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

MTS32-150M
SMC MTS32-150M
View Details

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

MXQ25L-40B-M9NZ
SMC MXQ25L-40B-M9NZ
View Details

SMC

MXQ25L-40B-M9NZ

MFR #MXQ25L-40B-M9NZ

SKU #YLSD1VANMRI726Z

BC8M12
Brush Research Mfg BC8M12
View Details

Brush Research Mfg

BC8M12

MFR #BC8M12

SKU #YLSA0P5BE6ZJCIW

CG5EN50SV-150
SMC CG5EN50SV-150
View Details

SMC

CG5EN50SV-150

MFR #CG5EN50SV-150

SKU #YLST11TLVYPVP7H

Related Searches

Siemens 3RW5214-3AC14 priceSiemens 3RW5214-3AC14 quotebuy Siemens 3RW5214-3AC143RW5214-3AC14 price3RW5214-3AC14 stock availabilitySiemens spare partsSiemens 3RW5214-3AC14 equivalentSiemens 3RW5214-3AC14 specifications