Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3RV2011-1JA10-ZW96

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3RV2011-1JA10-ZW96

Circuit breaker size S00 for motor protection, CLASS 10 A-release 7...10 A N release 130 A screw terminal Standard switching capacity Multi-unit packaging Pack = 24 units

SiemensMFR # 3RV2011-1JA10-ZW96SKU # CEY-8EF3B0392805
product brand nameSIRIUS
product designationCircuit breaker
design of the productFor motor protection
product type designation3RV2
size of the circuit-breakerS00
product extension auxiliary switchYes
Share

About This Product

Circuit breaker size S00 for motor protection, CLASS 10 A-release 7...10 A N release 130 A screw terminal Standard switching capacity Multi-unit packaging Pack = 24 units

Siemens 3RV2011-1JA10-ZW96

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product designationCircuit breaker
design of the productFor motor protection
product type designation3RV2
General technical data
Product equipment of circuit breaker for motor protection complete unit with protection deviceYes
size of the circuit-breakerS00
size of contactor can be combined company-specificS00, S0
product function disconnector functionalityYes
product extension auxiliary switchYes
at AC in hot operating state9.25 W
at AC in hot operating state per pole3.1 W
type of calculation of power loss current-dependentquadratic
insulation voltage with degree of pollution 3 at AC rated value690 V
surge voltage resistance rated value6 kV
in networks with ungrounded star point between main and auxiliary circuit400 V
in networks with grounded star point between main and auxiliary circuit400 V
on the front according to IEC 60529IP20
on the frontIP20
of the terminalIP20
shock resistance according to IEC 60068-2-2725g / 11 ms
of the main contacts typical100 000
of auxiliary contacts typical100 000
electrical endurance (operating cycles) typical100 000
reference code according to IEC 81346-2Q
continuous current rated value10 A
Substance Prohibitance (day/month/year)10/01/2009
Net Weight0.356 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-20 ... +60 °C
during storage-50 ... +80 °C
during transport-50 ... +80 °C
temperature compensation-20 ... +60 °C
relative humidity during operation10 ... 95 %
Main circuit
number of poles for main current circuit3
adjustable current response value current of the current-dependent overload release7 ... 10 A
type of voltage for main current circuitAC
rated value690 V
rated value20 ... 690 V
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
operating frequency rated value50 ... 60 Hz
operational current rated value10 A
at AC-3 at 400 V rated value10 A
at AC-3e at 400 V rated value10 A
— at 230 V rated value2.2 kW
— at 400 V rated value4 kW
— at 500 V rated value5.5 kW
— at 690 V rated value7.5 kW
— at 230 V rated value2.2 kW
— at 400 V rated value4 kW
— at 500 V rated value5.5 kW
— at 690 V rated value7.5 kW
at AC-3 maximum15 1/h
at AC-3e maximum15 1/h
Auxiliary circuit
type of voltage for auxiliary and control circuitAC/DC
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts0
number of CO contacts for auxiliary contacts0
Protective and monitoring functions
ground fault detectionNo
phase failure detectionYes
trip classCLASS 10
design of the overload releasethermal
at AC at 240 V rated value100 kA
at AC at 400 V rated value100 kA
at AC at 500 V rated value42 kA
at AC at 690 V rated value6 kA
at 240 V rated value100 kA
at 400 V rated value100 kA
at 500 V rated value42 kA
at 690 V rated value4 kA
response value current of instantaneous short-circuit trip unit130 A
UL/CSA ratings
at 480 V rated value10 A
at 600 V rated value10 A
— at 110/120 V rated value0.5 hp
— at 230 V rated value1.5 hp
— at 200/208 V rated value2 hp
— at 220/230 V rated value3 hp
— at 460/480 V rated value5 hp
— at 575/600 V rated value10 hp
UL File Number (CCN)E47705 (NLRV, NLRV7)
Short-circuit protection
product function short circuit protectionYes
design of the short-circuit tripmagnetic
at 400 VgL/gG 50 A
at 500 VgL/gG 40 A
at 690 VgL/gG 40 A
certificate of suitability according to ATEX directive 2014/34/EUDMT 02 ATEX F 001
type of protection according to ATEX directive 2014/34/EUEx II (2) GD
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting method of circuit breaker for Transformer protection, Generator protection and system protection optional standard bar mountingYes
height97 mm
width45 mm
depth97 mm
— forwards0 mm
— backwards0 mm
— upwards50 mm
— downwards50 mm
— at the side0 mm
— forwards0 mm
— backwards0 mm
— upwards50 mm
— at the side30 mm
— downwards50 mm
— forwards0 mm
— backwards0 mm
— upwards50 mm
— downwards50 mm
— at the side30 mm
— downwards30 mm
— upwards30 mm
— at the side9 mm
— downwards30 mm
— upwards30 mm
— at the side9 mm
— downwards30 mm
— upwards30 mm
— at the side9 mm
— downwards30 mm
— upwards30 mm
— at the side9 mm
— downwards50 mm
— upwards50 mm
— backwards0 mm
— at the side30 mm
— forwards0 mm
— downwards50 mm
— upwards50 mm
— backwards0 mm
— at the side30 mm
— forwards0 mm
Connections/ Terminals
product component removable terminal for auxiliary and control circuitNo
for main current circuitscrew-type terminals
arrangement of electrical connectors for main current circuitTop and bottom
— solid or stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for AWG cables for main contacts2x (18 ... 14), 2x 12
solid or stranded0.75 ... 4 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
AWG number as coded connectable conductor cross section for main contacts18 ... 12
for main contacts with screw-type terminals0.8 ... 1.2 N·m
design of screwdriver shaftDiameter 5 to 6 mm
size of the screwdriver tipPozidriv size 2
for main contactsM3
Safety related data
product function suitable for safety functionYes
safety-related switching onNo
safety-related switching OFFYes
service life maximum10 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192050 %
B10 value with high demand rate according to SN 319205 000
failure rate [FIT] with low demand rate according to SN 3192050 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
safety device type according to IEC 61508-2Type A
for proof test interval or service life according to IEC 6150810 a
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Display
display version for switching statusHandle
Approvals Certificates
global warming potential [CO2 eq] / during manufacturing1.98 kg
global warming potential [CO2 eq] / during sales0.134 kg
global warming potential [CO2 eq] / during operation72.7 kg
global warming potential [CO2 eq] / after end of life-0.116 kg
global warming potential [CO2 eq] / total74.698 kg

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
View Details

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
View Details

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

BC8M12
Brush Research Mfg BC8M12
View Details

Brush Research Mfg

BC8M12

MFR #BC8M12

SKU #YLSA0P5BE6ZJCIW

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

Related Searches

Siemens 3RV2011-1JA10-ZW96 priceSiemens 3RV2011-1JA10-ZW96 quotebuy Siemens 3RV2011-1JA10-ZW963RV2011-1JA10-ZW96 price3RV2011-1JA10-ZW96 stock availabilitySiemens spare partsSiemens 3RV2011-1JA10-ZW96 equivalentSiemens 3RV2011-1JA10-ZW96 specifications