product brand nameSIRIUS
product designationCircuit breaker
design of the productfor fuse monitoring
product type designation3RV1
General technical data
Product equipment of circuit breaker for motor protection complete unit with protection deviceYes
size of the circuit-breakerS00
product function disconnector functionalityYes
product extension auxiliary switchYes
at AC in hot operating state5.5 W
at AC in hot operating state per pole1.8 W
type of calculation of power loss current-dependentquadratic
insulation voltage with degree of pollution 3 at AC rated value690 V
surge voltage resistance rated value6 kV
in networks with ungrounded star point between main and auxiliary circuit400 V
in networks with grounded star point between main and auxiliary circuit400 V
on the front according to IEC 60529IP20
on the frontIP20
of the terminalIP00
of the main contacts typical100 000
of auxiliary contacts typical100 000
reference code according to IEC 81346-2Q
continuous current rated value0.2 A
Substance Prohibitance (day/month/year)01/01/2013
Net Weight0.21 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-20 ... +60 °C
during storage-50 ... +80 °C
during transport-50 ... +80 °C
temperature compensation-20 ... +60 °C
relative humidity during operation10 ... 95 %
Main circuit
number of poles for main current circuit3
type of voltage for main current circuitAC/DC
rated value690 V
rated value20 ... 690 V
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
operating frequency rated value50 ... 60 Hz
operational current rated value0.2 A
at AC-3 at 400 V rated value0.2 A
at AC-3e at 400 V rated value0.2 A
at AC-3 maximum15 1/h
at AC-3e maximum15 1/h
Auxiliary circuit
type of voltage for auxiliary and control circuitAC/DC
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts0
number of CO contacts for auxiliary contacts0
Protective and monitoring functions
ground fault detectionNo
phase failure detectionYes
design of the overload releasethermal
at AC at 240 V rated value100 kA
at AC at 400 V rated value100 kA
at AC at 500 V rated value100 kA
at AC at 690 V rated value100 kA
at 240 V rated value100 kA
at 400 V rated value100 kA
at 500 V rated value100 kA
at 690 V rated value100 kA
at 1 current path at DC at 150 V rated value10 kA
with 2 current paths in series at DC at 300 V rated value10 kA
with 3 current paths in series at DC at 450 V rated value10 kA
response value current of instantaneous short-circuit trip unit1.2 A
UL/CSA ratings
at 480 V rated value0.2 A
at 600 V rated value0.2 A
Short-circuit protection
product function short circuit protectionYes
design of the short-circuit tripmagnetic
at 240 Vnone required
at 400 VNone required
at 500 VNone required
at 690 VNone required
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting method of circuit breaker for Transformer protection, Generator protection and system protection optional standard bar mountingYes
height90 mm
width45 mm
depth75 mm
— downwards20 mm
— upwards20 mm
— at the side9 mm
— downwards20 mm
— upwards20 mm
— at the side9 mm
— downwards20 mm
— upwards20 mm
— at the side9 mm
— downwards20 mm
— upwards20 mm
— at the side9 mm
— downwards20 mm
— upwards20 mm
— backwards0 mm
— at the side9 mm
— forwards0 mm
— downwards20 mm
— upwards20 mm
— backwards0 mm
— at the side9 mm
— forwards0 mm
Connections/ Terminals
product component removable terminal for auxiliary and control circuitNo
for main current circuitscrew-type terminals
arrangement of electrical connectors for main current circuitTop and bottom
— solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x (1 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
solid or stranded0.5 ... 4 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
— solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
AWG number as coded connectable conductor cross section for main contacts18 ... 14
for main contacts with screw-type terminals0.8 ... 1.2 N·m
for auxiliary contacts with screw-type terminals0.8 ... 1.2 N·m
size of the screwdriver tipPozidriv size 2
for main contactsM3
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Display
display version for switching statusRocker switch