Special type Circuit breaker size S00 for motor protection CLASS 10 A-release 0.9...1.25 A N-release 16 A Screw terminal Standard switching capacity with transverse auxiliary switch 1 NO+1 NC Ambient temperature -50 °C 500 switching cycles

SiemensMFR # 3RV1011-0KA15-0BA0SKU # YLSNKZGQMVC8FZ9
size of the circuit-breakerS00
product extension auxiliary switchYes
at AC in hot operating state5.5 W
at AC in hot operating state per pole1.8 W
surge voltage resistance rated value6 kV
on the front according to IEC 60529IP20
Share

About This Product

Special type Circuit breaker size S00 for motor protection CLASS 10 A-release 0.9...1.25 A N-release 16 A Screw terminal Standard switching capacity with transverse auxiliary switch 1 NO+1 NC Ambient temperature -50 °C 500 switching cycles

Siemens 3RV1011-0KA15-0BA0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General technical data
Product equipment of circuit breaker for motor protection complete unit with protection deviceYes
size of the circuit-breakerS00
size of contactor can be combined company-specificS00
product function disconnector functionalityYes
product extension auxiliary switchYes
at AC in hot operating state5.5 W
at AC in hot operating state per pole1.8 W
type of calculation of power loss current-dependentquadratic
insulation voltage with degree of pollution 3 at AC rated value690 V
surge voltage resistance rated value6 kV
in networks with ungrounded star point between main and auxiliary circuit400 V
in networks with grounded star point between main and auxiliary circuit400 V
on the front according to IEC 60529IP20
on the frontIP20
of the terminalIP00
shock resistance according to IEC 60068-2-2725g / 11 ms
of the main contacts typical500
of auxiliary contacts typical500
electrical endurance (operating cycles) typical500
reference code according to IEC 81346-2Q
continuous current rated value1.25 A
Substance Prohibitance (day/month/year)01/01/2013
Net Weight327.18 g
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-50 ... +60 °C
during storage-50 ... +80 °C
during transport-50 ... +80 °C
temperature compensation-20 ... +60 °C
relative humidity during operation10 ... 95 %
Main circuit
number of poles for main current circuit3
type of voltage for main current circuitAC
rated value690 V
rated value20 ... 690 V
at AC-3 rated value maximum690 V
operating frequency rated value50 ... 60 Hz
operational current rated value1.25 A
at AC-3 at 400 V rated value1.25 A
— at 230 V rated value0.18 kW
— at 400 V rated value0.37 kW
— at 500 V rated value0.55 kW
— at 690 V rated value0.75 kW
at AC-3 maximum15 1/h
Auxiliary circuit
design of the auxiliary switchtransverse
type of voltage for auxiliary and control circuitAC/DC
number of NC contacts for auxiliary contacts1
number of NO contacts for auxiliary contacts1
number of CO contacts for auxiliary contacts0
at 24 V2 A
at 120 V0.5 A
at 125 V0.5 A
at 230 V0.5 A
at 24 V1 A
at 60 V0.15 A
Protective and monitoring functions
ground fault detectionNo
phase failure detectionYes
trip classCLASS 10
design of the overload releasethermal
protection function thermal overload protection (ANSI 49)Yes
at AC at 240 V rated value100 kA
at AC at 400 V rated value100 kA
at AC at 500 V rated value100 kA
at AC at 690 V rated value2 kA
at 240 V rated value100 kA
at 400 V rated value100 kA
at 500 V rated value100 kA
at 690 V rated value2 kA
response value current of instantaneous short-circuit trip unit16 A
Short-circuit protection
product function short circuit protectionYes
design of the short-circuit tripmagnetic
for short-circuit protection of the auxiliary switch requiredfuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)
at 240 Vnone required
at 400 VgG 20 A
at 500 VgG 16 A
at 690 VgG 16 A
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting method of circuit breaker for Transformer protection, Generator protection and system protection optional standard bar mountingYes
height90 mm
width45 mm
depth75 mm
— forwards0 mm
— backwards0 mm
— upwards20 mm
— downwards20 mm
— at the side0 mm
— forwards0 mm
— backwards0 mm
— upwards20 mm
— at the side9 mm
— downwards20 mm
— forwards0 mm
— backwards0 mm
— upwards20 mm
— downwards20 mm
— at the side9 mm
— downwards20 mm
— upwards20 mm
— at the side9 mm
— downwards20 mm
— upwards20 mm
— at the side9 mm
— downwards20 mm
— upwards20 mm
— at the side9 mm
— downwards20 mm
— upwards20 mm
— at the side9 mm
— downwards20 mm
— upwards20 mm
— backwards0 mm
— at the side9 mm
— forwards0 mm
— downwards20 mm
— upwards20 mm
— backwards0 mm
— at the side9 mm
— forwards0 mm
Connections/ Terminals
product component removable terminal for auxiliary and control circuitNo
for main current circuitscrew-type terminals
for auxiliary and control circuitscrew-type terminals
arrangement of electrical connectors for main current circuitTop and bottom
— solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x (1 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
solid or stranded0.5 ... 4 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
solid or stranded0.5 ... 2.5 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
— solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for main contacts with screw-type terminals0.8 ... 1.2 N·m
for auxiliary contacts with screw-type terminals0.8 ... 1.2 N·m
design of screwdriver shaftDiameter 5 to 6 mm
size of the screwdriver tipPozidriv size 2
for main contactsM3
of the auxiliary and control contactsM3
IEC 61508
for proof test interval or service life according to IEC 6150810 a
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Display
display version for switching statusRocker switch

Accessories 6

Genuine accessories that can be used with the Siemens 3RV1011-0KA15-0BA0 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
3RA1911-1AA00Aksesuar · Wiring modules, connectors and kits · link modules
3RV2928-0BAksesuar · Push-in lugs · push-in lugs
3RT2900-1SB20Aksesuar · Miscellaneous accessories · labeling plates
3RT2900-1SB60Aksesuar · Miscellaneous accessories · labeling plates
3RV1915-5AAksesuar · Plugs, adapters and terminals · infeed terminals
3RV2901-1EBileşen · Auxiliary switch · auxiliary switches

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
View Details

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

BC8M12
Brush Research Mfg BC8M12
View Details

Brush Research Mfg

BC8M12

MFR #BC8M12

SKU #YLSA0P5BE6ZJCIW

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

CG5EN50SV-150
SMC CG5EN50SV-150
View Details

SMC

CG5EN50SV-150

MFR #CG5EN50SV-150

SKU #YLST11TLVYPVP7H

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
View Details

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

Related Searches

Siemens 3RV1011-0KA15-0BA0 priceSiemens 3RV1011-0KA15-0BA0 quotebuy Siemens 3RV1011-0KA15-0BA03RV1011-0KA15-0BA0 price3RV1011-0KA15-0BA0 stock availabilitySiemens spare partsSiemens 3RV1011-0KA15-0BA0 equivalentSiemens 3RV1011-0KA15-0BA0 specifications