Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3RT2047-3SB30

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3RT2047-3SB30

power contactor, AC-3e/AC-3, 110 A, 55 kW / 400 V, 3-pole, 21-33 V AC/DC, 50/60 Hz, with integrated varistor, auxiliary contacts: 1 NC, main circuit: screw terminal, control and auxiliary circuit: spring-loaded terminal, size: S3, F-PLC-IN

SiemensMFR # 3RT2047-3SB30SKU # YLSRWK07M9QXOX
product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
size of contactorS3
function module for communicationNo
auxiliary switchYes
Share

About This Product

power contactor, AC-3e/AC-3, 110 A, 55 kW / 400 V, 3-pole, 21-33 V AC/DC, 50/60 Hz, with integrated varistor, auxiliary contacts: 1 NC, main circuit: screw terminal, control and auxiliary circuit: spring-loaded terminal, size: S3, F-PLC-IN

Siemens 3RT2047-3SB30

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
General technical data
size of contactorS3
function module for communicationNo
auxiliary switchYes
at AC in hot operating state23.7 W
at AC in hot operating state per pole7.9 W
without load current share typical3.5 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value1 000 V
of auxiliary circuit with degree of pollution 3 rated value690 V
of main circuit rated value8 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1690 V
at AC10.3 g / 5 ms, 6,7 g / 10 ms
at DC6.7 g / 5 ms, 4 g / 10 ms
at AC16.3 g / 5 ms, 10.5 g / 10 ms
at DC10.6 g / 5 ms, 6.3 g / 10 ms
of contactor typical5 000 000
of the contactor with added electronically optimized auxiliary switch block typical5 000 000
of the contactor with added auxiliary switch block typical5 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)01/29/2021
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1
Net Weight1.746 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum1 000 V
at AC-3e rated value maximum1 000 V
at AC-1 at 400 V at ambient temperature 40 °C rated value130 A
— up to 690 V at ambient temperature 40 °C rated value130 A
— up to 690 V at ambient temperature 60 °C rated value110 A
— at 400 V rated value110 A
— at 500 V rated value110 A
— at 690 V rated value98 A
— at 1000 V rated value30 A
— at 400 V rated value110 A
— at 500 V rated value110 A
— at 690 V rated value98 A
— at 1000 V rated value30 A
at AC-4 at 400 V rated value97 A
at AC-5a up to 690 V rated value120 A
at AC-5b up to 400 V rated value110 A
— up to 230 V for current peak value n=20 rated value98 A
— up to 400 V for current peak value n=20 rated value98 A
— up to 500 V for current peak value n=20 rated value98 A
— up to 690 V for current peak value n=20 rated value98 A
— up to 230 V for current peak value n=30 rated value65.3 A
— up to 400 V for current peak value n=30 rated value65.3 A
— up to 500 V for current peak value n=30 rated value65.3 A
— up to 690 V for current peak value n=30 rated value65.3 A
minimum cross-section in main circuit at maximum AC-1 rated value50 mm²
at 400 V rated value46 A
at 690 V rated value36 A
— at 24 V rated value100 A
— at 60 V rated value60 A
— at 110 V rated value9 A
— at 220 V rated value2 A
— at 440 V rated value0.6 A
— at 600 V rated value0.4 A
— at 24 V rated value100 A
— at 60 V rated value100 A
— at 110 V rated value100 A
— at 220 V rated value10 A
— at 440 V rated value1.8 A
— at 600 V rated value1 A
— at 24 V rated value100 A
— at 60 V rated value100 A
— at 110 V rated value100 A
— at 220 V rated value80 A
— at 440 V rated value4.5 A
— at 600 V rated value2.6 A
— at 24 V rated value40 A
— at 60 V rated value6 A
— at 110 V rated value2.5 A
— at 220 V rated value1 A
— at 440 V rated value0.15 A
— at 600 V rated value0.06 A
— at 24 V rated value100 A
— at 60 V rated value100 A
— at 110 V rated value100 A
— at 220 V rated value7 A
— at 440 V rated value0.42 A
— at 600 V rated value0.16 A
— at 24 V rated value100 A
— at 60 V rated value100 A
— at 110 V rated value100 A
— at 220 V rated value35 A
— at 440 V rated value0.8 A
— at 600 V rated value0.35 A
at AC-2 at 400 V rated value55 kW
— at 230 V rated value30 kW
— at 400 V rated value55 kW
— at 500 V rated value75 kW
— at 690 V rated value90 kW
— at 1000 V rated value37 kW
— at 230 V rated value30 kW
— at 400 V rated value55 kW
— at 500 V rated value75 kW
— at 690 V rated value90 kW
— at 1000 V rated value37 kW
at 400 V rated value24.3 kW
at 690 V rated value32.9 kW
up to 400 V for current peak value n=20 rated value67 kVA
up to 500 V for current peak value n=20 rated value84 kVA
up to 690 V for current peak value n=20 rated value117 kVA
up to 230 V for current peak value n=30 rated value26 kVA
up to 400 V for current peak value n=30 rated value45.2 kVA
up to 500 V for current peak value n=30 rated value56.5 kVA
up to 690 V for current peak value n=30 rated value78 kVA
limited to 1 s switching at zero current maximum1 960 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum1 502 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum1 095 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum707 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum562 A; Use minimum cross-section acc. to AC-1 rated value
at AC1 000 1/h
at DC1 000 1/h
at AC-1 maximum900 1/h
at AC-2 maximum350 1/h
at AC-3 maximum850 1/h
— maximum850 1/h
at AC-4 maximum200 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
at 50 Hz rated value21 ... 33 V
at 60 Hz rated value21 ... 33 V
control supply voltage at DC rated value21 ... 33 V
initial value0.8
full-scale value1.1
at 50 Hz0.8 ... 1.1
at 60 Hz0.8 ... 1.1
type of PLC-control input according to IEC 60947-1Type 1
consumed current at PLC-control input according to IEC 60947-1 maximum11 mA
voltage at PLC-control input rated value24 V
operating range factor of the voltage at PLC-control input0.8 ... 1.1
design of the surge suppressorwith varistor
inrush current peak2.2 A
duration of inrush current peak100 µs
pickup current mean value4.5 A
pickup current peak7.2 A
duration of pickup current150 ms
holding current mean value0.09 A
at 50 Hz163 V·A
at 60 Hz163 V·A
at minimum rated control supply voltage at DC1.8 V·A
at maximum rated control supply voltage at DC1.8 V·A
— at 50 Hz2.4 V·A
— at 60 Hz2.4 V·A
— at 50 Hz2.4 V·A
— at 60 Hz2.4 V·A
at 50 Hz2.4 V·A
at 60 Hz2.4 V·A
at 50 Hz0.95
at 60 Hz0.95
closing power of magnet coil at DC130 W
holding power of magnet coil at DC1.8 W
at AC50 ... 70 ms
at DC50 ... 70 ms
at AC38 ... 57 ms
at DC38 ... 57 ms
recovery time after power failure typical2.1 s
arcing time10 ... 20 ms
control version of the switch operating mechanismFail-safe PLC input (F-PLC-IN)
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact1
number of NO contacts for auxiliary contacts instantaneous contact0
operational current at AC-12 maximum10 A
at 230 V rated value6 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0.15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0.9 A
at 220 V rated value0.3 A
at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
at 480 V rated value96 A
at 600 V rated value99 A
— at 110/120 V rated value10 hp
— at 230 V rated value20 hp
— at 200/208 V rated value30 hp
— at 220/230 V rated value40 hp
— at 460/480 V rated value75 hp
— at 575/600 V rated value100 hp
contact rating of auxiliary contacts according to ULA600 / P600
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
— with type of coordination 1 requiredgG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
— with type of coordination 2 requiredgG: 200 A (690 V, 100 kA), aM: 100 A (690 V, 100 kA), BS88: 160 A (415 V, 80 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method side-by-side mountingYes
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height140 mm
width70 mm
depth198 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards20 mm
— upwards10 mm
— at the side10 mm
— downwards10 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
Connections/ Terminals
for main current circuitscrew-type terminals
for auxiliary and control circuitspring-loaded terminals
at contactor for auxiliary contactsSpring-type terminals
of magnet coilSpring-loaded terminal
— finely stranded with core end processing2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)
for AWG cables for main contacts2x (10 ... 1/0), 1x (10 ... 2/0)
solid2.5 ... 16 mm²
stranded6 ... 70 mm²
finely stranded with core end processing2.5 ... 50 mm²
solid or stranded0.5 ... 2.5 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
finely stranded without core end processing0.5 ... 2.5 mm²
— solid or stranded2x (0.5 ... 2.5 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²)
— finely stranded without core end processing2x (0.5 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 16)
AWG number extended as coded connectable conductor cross section for main contacts10 ... 2/0
AWG number as coded connectable conductor cross section for auxiliary contacts20 ... 14
Safety related data
mirror contact according to IEC 60947-4-1Yes
positively driven operation according to IEC 60947-5-1No
suitable for safety functionYes
suitability for use safety-related switching OFFYes
safe stateoff
test wear-related service life necessaryYes
diagnostics test interval by internal test function maximum28 800 s
stop category according to IEC 60204-10
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
MTBF52 a
IEC 62061
Safety Integrity Level (SIL) according to IEC 62061SIL 2
PFHD with high demand rate according to IEC 620617.7E-8 1/h
ISO 13849
performance level (PL) according to ISO 13849-1PL c
category according to ISO 13849-12
device type according to ISO 13849-11
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
Safety Integrity Level (SIL) according to IEC 615082
safety device type according to IEC 61508-2Type B
PFHD with high demand rate according to IEC 615087.7E-8 1/h
PFDavg with low demand rate according to IEC 615080.0067
Safe failure fraction (SFF)96 %
hardware fault tolerance according to IEC 615080
T1 value of service life according to IEC 6150820 a
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front

Accessories 79

Genuine accessories that can be used with the Siemens 3RT2047-3SB30 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
3RH2911-2HA22Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2FA22Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA22-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RT2946-4GAksesuar · Terminal covers · box terminal blocks
3RA2942-2FAksesuar · Base plates · base plates
3RH2911-2FA40Aksesuar · Auxiliary switch · auxiliary switches
3RT2936-1ER00Aksesuar · Surge suppressor · diode assemblies
3RH2911-2HA11Aksesuar · Auxiliary switch · auxiliary switches
3RH2921-2DE11Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA31Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA12Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA40-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA01Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA31-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RA2934-2BAksesuar · Mechanical interlocks · mechanical interlocks
3RT2936-4MC00Aksesuar · Miscellaneous accessories · Control Kits
3RA2943-3LAksesuar · Plugs, adapters and terminals · infeed terminals
3RH2914-2GP11Aksesuar · Coupling links · coupling links
3RT2900-1SB10Aksesuar · Miscellaneous accessories · labeling plates
3RA2813-2FW10Aksesuar
3RT2916-4MA10Aksesuar · Sealing covers · sealing covers
3RT2946-1CB00Aksesuar · Surge suppressor · RC elements
3RT2936-1ES00Aksesuar · Surge suppressor · diode assemblies
3RT2900-1SB20Aksesuar · Miscellaneous accessories · labeling plates
3RT2900-1SB60Aksesuar · Miscellaneous accessories · labeling plates
3RT1946-4BB31Aksesuar · Wiring modules, connectors and kits · coil connectors
3RA2816-0EW20Aksesuar
3RT2926-1QT00Aksesuar · LED modules · LED display indicator modules
3RA2943-2AA1Aksesuar · Wiring modules, connectors and kits · wiring kits
3RT2946-4FAksesuar · Terminal covers · auxiliary conductor terminals
3RH2921-2DA11Aksesuar · Auxiliary switch · auxiliary switches
3RH2921-2DA02Aksesuar · Auxiliary switch · auxiliary switches
3RH2921-2DA20Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA03Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA10Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA21Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA30Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NE21Aksesuar · Auxiliary switch · auxiliary switches
3RT2916-2BE01Aksesuar · OFF-delay device · OFF-delay device
3RT1946-4BA31Aksesuar · Wiring modules, connectors and kits · coil connectors
3RH2911-2FA04Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2FB22-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA04-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA11-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA20-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XB22-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2916-2XA22-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NL22Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NL40Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NM31Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA13-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NF20Aksesuar · Auxiliary switch · auxiliary switches
3RA2815-2FW10Aksesuar
3RH2911-2NF02Aksesuar · Auxiliary switch · auxiliary switches
3RA2932-2DAksesuar · Mechanical interlocks · mechanical connectors
3RA2943-2CAksesuar · Wiring modules, connectors and kits · wiring kits
3RA1943-3DAksesuar · Wiring modules, connectors and kits · link modules
3RA1943-3EAksesuar · Wiring modules, connectors and kits · link modules
3RA1953-3GAksesuar · Wiring modules, connectors and kits · link rails
3RA1954-2GAksesuar · Mechanical interlocks · mechanical connectors
3RH2911-2NF22Aksesuar · Auxiliary switch · auxiliary switches
3RH2916-2FA22Aksesuar · Auxiliary switch · auxiliary switches
3RA2813-2AW10Aksesuar
3RA2814-2AW10Aksesuar
3RA2814-2FW10Aksesuar
3RA2815-2AW10Aksesuar
3RA2831-2DG10Aksesuar
3RA2831-2DH10Aksesuar
3RA2832-2DG10Aksesuar
3RA2832-2DH10Aksesuar
3RA2908-1AAksesuar · Miscellaneous accessories · screwdrivers
3RA2943-2BB1Aksesuar · Wiring modules, connectors and kits · wiring kits
3RH2911-2HA02Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA20Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2FB11Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2FB22Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2FC22Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA13Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NF11Aksesuar · Auxiliary switch · auxiliary switches

Related Products

1EE1122-..A00-...4
Siemens 1EE1122-..A00-...4
View Details

Siemens

1EE1122-..A00-...4

MFR #1EE1122-..A00-...4

SKU #YLS3FGFZLYE3EV8

1EE1124-..A00-...4
Siemens 1EE1124-..A00-...4
View Details

Siemens

1EE1124-..A00-...4

MFR #1EE1124-..A00-...4

SKU #YLSKZIN1GEIPRVP

1EE1142-..A00-...4
Siemens 1EE1142-..A00-...4
View Details

Siemens

1EE1142-..A00-...4

MFR #1EE1142-..A00-...4

SKU #YLSUX3MNEZEJGPU

1EE1144-..A00-...4
Siemens 1EE1144-..A00-...4
View Details

Siemens

1EE1144-..A00-...4

MFR #1EE1144-..A00-...4

SKU #YLSD9GON9QOYBAE

1EE1322-....0-...4
Siemens 1EE1322-....0-...4
View Details

Siemens

1EE1322-....0-...4

MFR #1EE1322-....0-...4

SKU #YLSSAVZE8P7OOP6

1EE1322-...00-1..2
Siemens 1EE1322-...00-1..2
View Details

Siemens

1EE1322-...00-1..2

MFR #1EE1322-...00-1..2

SKU #YLSY69IQB2JXAXJ

1EE1322-..A00-...4
Siemens 1EE1322-..A00-...4
View Details

Siemens

1EE1322-..A00-...4

MFR #1EE1322-..A00-...4

SKU #YLSH1E6AJR6XWJF

1EE1324-....0-...4
Siemens 1EE1324-....0-...4
View Details

Siemens

1EE1324-....0-...4

MFR #1EE1324-....0-...4

SKU #YLS8GBB9BXAF83

1EE1324-...00-1..2
Siemens 1EE1324-...00-1..2
View Details

Siemens

1EE1324-...00-1..2

MFR #1EE1324-...00-1..2

SKU #YLSLOS6I1BDXR58

1EE1324-..A00-...4
Siemens 1EE1324-..A00-...4
View Details

Siemens

1EE1324-..A00-...4

MFR #1EE1324-..A00-...4

SKU #YLSE0T3LUEU0CI

Featured Products

MY1M20-200AH
SMC MY1M20-200AH
View Details

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

MTS32-150M
SMC MTS32-150M
View Details

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
View Details

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
View Details

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

Related Searches