power contactor, AC-3e/AC-3, 80 A, 37 kW / 400 V, 3-pole, 230 V AC, 50/60 Hz, auxiliary contacts: 1 NO + 1 NC, main circuit: screw terminal, control and auxiliary circuit: spring-loaded terminal, size: S2, multi-unit packaging, pack = 6 units

SiemensMFR # 3RT2038-3AL20-ZW97SKU # CEY-8EF3B039370C
product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
size of contactorS2
function module for communicationNo
auxiliary switchYes
Share

About This Product

power contactor, AC-3e/AC-3, 80 A, 37 kW / 400 V, 3-pole, 230 V AC, 50/60 Hz, auxiliary contacts: 1 NO + 1 NC, main circuit: screw terminal, control and auxiliary circuit: spring-loaded terminal, size: S2, multi-unit packaging, pack = 6 units

Siemens 3RT2038-3AL20-ZW97

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
General technical data
size of contactorS2
function module for communicationNo
auxiliary switchYes
at AC in hot operating state17.1 W
at AC in hot operating state per pole5.7 W
without load current share typical6.5 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value690 V
of auxiliary circuit with degree of pollution 3 rated value690 V
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
at AC11.8 g / 5 ms, 7.4 g / 10 ms
at AC18.5 g / 5 ms, 11.6 g / 10 ms
of contactor typical10 000 000
of the contactor with added electronically optimized auxiliary switch block typical5 000 000
of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2014
Net Weight1.013 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at AC-1 at 400 V at ambient temperature 40 °C rated value90 A
— up to 690 V at ambient temperature 40 °C rated value90 A
— up to 690 V at ambient temperature 60 °C rated value80 A
— at 400 V rated value80 A
— at 500 V rated value80 A
— at 690 V rated value58 A
— at 400 V rated value80 A
— at 500 V rated value80 A
— at 690 V rated value58 A
at AC-4 at 400 V rated value55 A
at AC-5a up to 690 V rated value79.2 A
at AC-5b up to 400 V rated value66.4 A
— up to 230 V for current peak value n=20 rated value70 A
— up to 400 V for current peak value n=20 rated value70 A
— up to 500 V for current peak value n=20 rated value70 A
— up to 690 V for current peak value n=20 rated value58 A
— up to 230 V for current peak value n=30 rated value46.7 A
— up to 400 V for current peak value n=30 rated value46.7 A
— up to 500 V for current peak value n=30 rated value46.7 A
— up to 690 V for current peak value n=30 rated value46.7 A
minimum cross-section in main circuit at maximum AC-1 rated value35 mm²
at 400 V rated value30 A
at 690 V rated value24 A
— at 24 V rated value55 A
— at 60 V rated value23 A
— at 110 V rated value4.5 A
— at 220 V rated value1 A
— at 440 V rated value0.4 A
— at 600 V rated value0.25 A
— at 24 V rated value55 A
— at 60 V rated value45 A
— at 110 V rated value45 A
— at 220 V rated value5 A
— at 440 V rated value1 A
— at 600 V rated value0.8 A
— at 24 V rated value55 A
— at 60 V rated value55 A
— at 110 V rated value55 A
— at 220 V rated value45 A
— at 440 V rated value2.9 A
— at 600 V rated value1.4 A
— at 24 V rated value35 A
— at 60 V rated value6 A
— at 220 V rated value1 A
— at 440 V rated value0.1 A
— at 600 V rated value0.06 A
— at 24 V rated value55 A
— at 60 V rated value45 A
— at 110 V rated value25 A
— at 220 V rated value5 A
— at 440 V rated value0.27 A
— at 600 V rated value0.16 A
— at 24 V rated value55 A
— at 60 V rated value55 A
— at 110 V rated value55 A
— at 220 V rated value25 A
— at 440 V rated value0.6 A
— at 600 V rated value0.35 A
at AC-2 at 400 V rated value37 kW
— at 230 V rated value22 kW
— at 400 V rated value37 kW
— at 500 V rated value37 kW
— at 690 V rated value45 kW
— at 230 V rated value22 kW
— at 400 V rated value37 kW
— at 500 V rated value37 kW
— at 690 V rated value45 kW
at 400 V rated value15.8 kW
at 690 V rated value21.8 kW
up to 230 V for current peak value n=20 rated value27.8 kVA
up to 400 V for current peak value n=20 rated value48.4 kVA
up to 500 V for current peak value n=20 rated value60.6 kVA
up to 690 V for current peak value n=20 rated value69.3 kVA
up to 230 V for current peak value n=30 rated value18.6 kVA
up to 400 V for current peak value n=30 rated value32.3 kVA
up to 500 V for current peak value n=30 rated value40.4 kVA
up to 690 V for current peak value n=30 rated value55.8 kVA
limited to 1 s switching at zero current maximum1 298 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum898 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum640 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum414 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum333 A; Use minimum cross-section acc. to AC-1 rated value
at AC5 000 1/h
at AC-1 maximum700 1/h
at AC-2 maximum350 1/h
at AC-3 maximum500 1/h
— maximum500 1/h
at AC-4 maximum150 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC
at 50 Hz rated value230 V
at 60 Hz rated value230 V
at 50 Hz0.8 ... 1.1
at 60 Hz0.85 ... 1.1
at 50 Hz210 V·A
at 60 Hz188 V·A
at 50 Hz0.69
at 60 Hz0.65
at 50 Hz17.2 V·A
at 60 Hz16.5 V·A
at 50 Hz0.36
at 60 Hz0.39
at AC10 ... 80 ms
at AC10 ... 18 ms
arcing time10 ... 20 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact1
number of NO contacts for auxiliary contacts instantaneous contact1
operational current at AC-12 maximum10 A
at 230 V rated value10 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0.15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0.9 A
at 220 V rated value0.3 A
at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
at 480 V rated value65 A
at 600 V rated value62 A
— at 110/120 V rated value5 hp
— at 230 V rated value15 hp
— at 200/208 V rated value20 hp
— at 220/230 V rated value25 hp
— at 460/480 V rated value50 hp
— at 575/600 V rated value60 hp
contact rating of auxiliary contacts according to ULA600 / P600
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
— with type of coordination 1 requiredgG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
— with type of coordination 2 requiredgG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method side-by-side mountingYes
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height114 mm
width55 mm
depth130 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
for main current circuitscrew-type terminals
for auxiliary and control circuitspring-loaded terminals
at contactor for auxiliary contactsSpring-type terminals
of magnet coilSpring-loaded terminal
— solid or stranded2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
— finely stranded with core end processing2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
for AWG cables for main contacts2x (18 ... 2), 1x (18 ... 1)
finely stranded with core end processing1 ... 35 mm²
solid or stranded0.5 ... 2.5 mm²
finely stranded with core end processing0.5 ... 1.5 mm²
finely stranded without core end processing0.5 ... 2.5 mm²
— solid or stranded2x (0.5 ... 2.5 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²)
— finely stranded without core end processing2x (0.5 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 14)
AWG number as coded connectable conductor cross section for main contacts18 ... 1
AWG number as coded connectable conductor cross section for auxiliary contacts20 ... 14
Safety related data
mirror contact according to IEC 60947-4-1Yes
positively driven operation according to IEC 60947-5-1No
suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

MY1M20-200AH
SMC MY1M20-200AH
View Details

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

MXQ25L-40B-M9NZ
SMC MXQ25L-40B-M9NZ
View Details

SMC

MXQ25L-40B-M9NZ

MFR #MXQ25L-40B-M9NZ

SKU #YLSD1VANMRI726Z

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
View Details

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

Related Searches

Siemens 3RT2038-3AL20-ZW97 priceSiemens 3RT2038-3AL20-ZW97 quotebuy Siemens 3RT2038-3AL20-ZW973RT2038-3AL20-ZW97 price3RT2038-3AL20-ZW97 stock availabilitySiemens spare partsSiemens 3RT2038-3AL20-ZW97 equivalentSiemens 3RT2038-3AL20-ZW97 specifications