Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3RT2035-1AL20-ZW97

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3RT2035-1AL20-ZW97

power contactor, AC-3e/AC-3, 41 A, 18.5 kW / 400 V, 3-pole, 230 V AC, 50/60 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S2, multi-unit packaging, pack = 6 units

SiemensMFR # 3RT2035-1AL20-ZW97SKU # CEY-8EF3B0393C75
product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
size of contactorS2
function module for communicationNo
auxiliary switchYes
Share

About This Product

power contactor, AC-3e/AC-3, 41 A, 18.5 kW / 400 V, 3-pole, 230 V AC, 50/60 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S2, multi-unit packaging, pack = 6 units

Siemens 3RT2035-1AL20-ZW97

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
General technical data
size of contactorS2
function module for communicationNo
auxiliary switchYes
at AC in hot operating state6.6 W
at AC in hot operating state per pole2.2 W
without load current share typical6.5 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value690 V
of auxiliary circuit with degree of pollution 3 rated value690 V
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
at AC11.8 g / 5 ms, 7.4 g / 10 ms
at AC18.5 g / 5 ms, 11.6 g / 10 ms
of contactor typical10 000 000
of the contactor with added electronically optimized auxiliary switch block typical5 000 000
of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2014
Net Weight1.01 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at AC-1 at 400 V at ambient temperature 40 °C rated value60 A
— up to 690 V at ambient temperature 40 °C rated value60 A
— up to 690 V at ambient temperature 60 °C rated value55 A
— at 400 V rated value41 A
— at 500 V rated value41 A
— at 690 V rated value24 A
— at 400 V rated value41 A
— at 500 V rated value41 A
— at 690 V rated value24 A
at AC-4 at 400 V rated value35 A
at AC-5a up to 690 V rated value52.8 A
at AC-5b up to 400 V rated value33.2 A
— up to 230 V for current peak value n=20 rated value36.5 A
— up to 400 V for current peak value n=20 rated value36.5 A
— up to 500 V for current peak value n=20 rated value36.5 A
— up to 690 V for current peak value n=20 rated value24 A
— up to 230 V for current peak value n=30 rated value24.2 A
— up to 400 V for current peak value n=30 rated value24.2 A
— up to 500 V for current peak value n=30 rated value24.2 A
— up to 690 V for current peak value n=30 rated value24 A
minimum cross-section in main circuit at maximum AC-1 rated value16 mm²
at 400 V rated value22 A
at 690 V rated value18.5 A
— at 24 V rated value55 A
— at 60 V rated value23 A
— at 110 V rated value4.5 A
— at 220 V rated value1 A
— at 440 V rated value0.4 A
— at 600 V rated value0.25 A
— at 24 V rated value55 A
— at 60 V rated value45 A
— at 110 V rated value45 A
— at 220 V rated value5 A
— at 440 V rated value1 A
— at 600 V rated value0.8 A
— at 24 V rated value55 A
— at 60 V rated value55 A
— at 110 V rated value55 A
— at 220 V rated value45 A
— at 440 V rated value2.9 A
— at 600 V rated value1.4 A
— at 24 V rated value35 A
— at 60 V rated value6 A
— at 220 V rated value1 A
— at 440 V rated value0.1 A
— at 600 V rated value0.06 A
— at 24 V rated value55 A
— at 60 V rated value45 A
— at 110 V rated value25 A
— at 220 V rated value5 A
— at 440 V rated value0.27 A
— at 600 V rated value0.16 A
— at 24 V rated value55 A
— at 60 V rated value55 A
— at 110 V rated value55 A
— at 220 V rated value25 A
— at 440 V rated value0.6 A
— at 600 V rated value0.35 A
at AC-2 at 400 V rated value18.5 kW
— at 230 V rated value11 kW
— at 400 V rated value18.5 kW
— at 500 V rated value22 kW
— at 690 V rated value22 kW
— at 230 V rated value11 kW
— at 400 V rated value18.5 kW
— at 500 V rated value22 kW
— at 690 V rated value22 kW
at 400 V rated value11.6 kW
at 690 V rated value16.8 kW
up to 230 V for current peak value n=20 rated value14.5 kVA
up to 400 V for current peak value n=20 rated value25.2 kVA
up to 500 V for current peak value n=20 rated value31.6 kVA
up to 690 V for current peak value n=20 rated value28.6 kVA
up to 230 V for current peak value n=30 rated value9.6 kVA
up to 400 V for current peak value n=30 rated value16.8 kVA
up to 500 V for current peak value n=30 rated value21 kVA
up to 690 V for current peak value n=30 rated value28.6 kVA
limited to 1 s switching at zero current maximum843 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum596 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum400 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum241 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum196 A; Use minimum cross-section acc. to AC-1 rated value
at AC5 000 1/h
at AC-1 maximum1 200 1/h
at AC-2 maximum750 1/h
at AC-3 maximum1 000 1/h
— maximum1 000 1/h
at AC-4 maximum300 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC
at 50 Hz rated value230 V
at 60 Hz rated value230 V
at 50 Hz0.8 ... 1.1
at 60 Hz0.85 ... 1.1
at 50 Hz210 V·A
at 60 Hz188 V·A
at 50 Hz0.69
at 60 Hz0.65
at 50 Hz17.2 V·A
at 60 Hz16.5 V·A
at 50 Hz0.36
at 60 Hz0.39
at AC10 ... 80 ms
at AC10 ... 18 ms
arcing time10 ... 20 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact1
number of NO contacts for auxiliary contacts instantaneous contact1
operational current at AC-12 maximum10 A
at 230 V rated value10 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0.15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0.9 A
at 220 V rated value0.3 A
at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
at 480 V rated value40 A
at 600 V rated value41 A
— at 110/120 V rated value3 hp
— at 230 V rated value7.5 hp
— at 200/208 V rated value10 hp
— at 220/230 V rated value15 hp
— at 460/480 V rated value30 hp
— at 575/600 V rated value40 hp
contact rating of auxiliary contacts according to ULA600 / P600
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
— with type of coordination 1 requiredgG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
— with type of coordination 2 requiredgG: 80 A (690 V, 100 kA), aM: 50 A (690 V, 100 kA), BS88: 63 A (415 V, 80 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method side-by-side mountingYes
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height114 mm
width55 mm
depth130 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
for main current circuitscrew-type terminals
for auxiliary and control circuitscrew-type terminals
at contactor for auxiliary contactsScrew-type terminals
of magnet coilscrew terminal
— solid or stranded2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
— finely stranded with core end processing2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
for AWG cables for main contacts2x (18 ... 2), 1x (18 ... 1)
finely stranded with core end processing1 ... 35 mm²
solid or stranded0.5 ... 2.5 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
— solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
AWG number as coded connectable conductor cross section for main contacts18 ... 1
AWG number as coded connectable conductor cross section for auxiliary contacts20 ... 14
Safety related data
mirror contact according to IEC 60947-4-1Yes
positively driven operation according to IEC 60947-5-1No
suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

AW20-N02CG-6CZ-B
SMC AW20-N02CG-6CZ-B
View Details

SMC

AW20-N02CG-6CZ-B

MFR #AW20-N02CG-6CZ-B

SKU #YLSNOOF0IBCZ3J3

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
View Details

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

CG5EN50SV-150
SMC CG5EN50SV-150
View Details

SMC

CG5EN50SV-150

MFR #CG5EN50SV-150

SKU #YLST11TLVYPVP7H

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

Related Searches

Siemens 3RT2035-1AL20-ZW97 priceSiemens 3RT2035-1AL20-ZW97 quotebuy Siemens 3RT2035-1AL20-ZW973RT2035-1AL20-ZW97 price3RT2035-1AL20-ZW97 stock availabilitySiemens spare partsSiemens 3RT2035-1AL20-ZW97 equivalentSiemens 3RT2035-1AL20-ZW97 specifications