Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3RT2018-1AP62

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3RT2018-1AP62

power contactor, AC-3e/AC-3, 16 A, 7.5 kW / 400 V, 3-pole, 220 V AC, 50 Hz / 240 V, 60 Hz, auxiliary contacts: 1 NC, screw terminal, size: S00

SiemensMFR # 3RT2018-1AP62SKU # CEY-8EF3B0393A80
product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
size of contactorS00
function module for communicationNo
auxiliary switchYes
Share

About This Product

power contactor, AC-3e/AC-3, 16 A, 7.5 kW / 400 V, 3-pole, 220 V AC, 50 Hz / 240 V, 60 Hz, auxiliary contacts: 1 NC, screw terminal, size: S00

Siemens 3RT2018-1AP62

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
General technical data
size of contactorS00
function module for communicationNo
auxiliary switchYes
at AC in hot operating state3 W
at AC in hot operating state per pole1 W
without load current share typical1.7 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value690 V
of auxiliary circuit with degree of pollution 3 rated value690 V
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
at AC7,3 g / 5 ms, 4,7 g / 10 ms
at AC11,4 g / 5 ms, 7,3 g / 10 ms
of contactor typical30 000 000
of the contactor with added electronically optimized auxiliary switch block typical5 000 000
of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2009
Net Weight0.224 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at AC-1 at 400 V at ambient temperature 40 °C rated value22 A
— up to 690 V at ambient temperature 40 °C rated value22 A
— up to 690 V at ambient temperature 60 °C rated value20 A
— at 400 V rated value16 A
— at 500 V rated value12.4 A
— at 690 V rated value8.9 A
— at 400 V rated value16 A
— at 500 V rated value12.4 A
— at 690 V rated value8.9 A
at AC-4 at 400 V rated value11.5 A
at AC-5a up to 690 V rated value19.4 A
at AC-5b up to 400 V rated value13.2 A
— up to 230 V for current peak value n=20 rated value9.6 A
— up to 400 V for current peak value n=20 rated value9.6 A
— up to 500 V for current peak value n=20 rated value9.6 A
— up to 690 V for current peak value n=20 rated value8.9 A
— up to 230 V for current peak value n=30 rated value6.6 A
— up to 400 V for current peak value n=30 rated value6.4 A
— up to 500 V for current peak value n=30 rated value6.4 A
— up to 690 V for current peak value n=30 rated value6.4 A
minimum cross-section in main circuit at maximum AC-1 rated value4 mm²
at 400 V rated value5.5 A
at 690 V rated value4.4 A
— at 24 V rated value20 A
— at 60 V rated value20 A
— at 110 V rated value2.1 A
— at 220 V rated value0.8 A
— at 440 V rated value0.6 A
— at 600 V rated value0.6 A
— at 24 V rated value20 A
— at 60 V rated value20 A
— at 110 V rated value12 A
— at 220 V rated value1.6 A
— at 440 V rated value0.8 A
— at 600 V rated value0.7 A
— at 24 V rated value20 A
— at 60 V rated value20 A
— at 110 V rated value20 A
— at 220 V rated value20 A
— at 440 V rated value1.3 A
— at 600 V rated value1 A
— at 24 V rated value20 A
— at 60 V rated value0.5 A
— at 110 V rated value0.15 A
— at 24 V rated value20 A
— at 60 V rated value5 A
— at 110 V rated value0.35 A
— at 24 V rated value20 A
— at 60 V rated value20 A
— at 110 V rated value20 A
— at 220 V rated value1.5 A
— at 440 V rated value0.2 A
— at 600 V rated value0.2 A
at AC-2 at 400 V rated value7.5 kW
— at 230 V rated value4 kW
— at 400 V rated value7.5 kW
— at 500 V rated value7.5 kW
— at 690 V rated value7.5 kW
— at 230 V rated value4 kW
— at 400 V rated value7.5 kW
— at 500 V rated value7.5 kW
— at 690 V rated value7.5 kW
at 400 V rated value2.5 kW
at 690 V rated value3.5 kW
up to 230 V for current peak value n=20 rated value3.8 kVA
up to 400 V for current peak value n=20 rated value6.6 kVA
up to 500 V for current peak value n=20 rated value8.3 kVA
up to 690 V for current peak value n=20 rated value10.6 kVA
up to 230 V for current peak value n=30 rated value2.5 kVA
up to 400 V for current peak value n=30 rated value4.4 kVA
up to 500 V for current peak value n=30 rated value5.5 kVA
up to 690 V for current peak value n=30 rated value7.6 kVA
limited to 1 s switching at zero current maximum300 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum169 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum128 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum92 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum74 A; Use minimum cross-section acc. to AC-1 rated value
at AC10 000 1/h
at AC-1 maximum1 000 1/h
at AC-2 maximum750 1/h
at AC-3 maximum750 1/h
— maximum750 1/h
at AC-4 maximum250 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC
at 50 Hz rated value220 V
at 60 Hz rated value240 V
at 50 Hz0.8 ... 1.1
at 60 Hz0.8 ... 1.1
at 50 Hz36 V·A
at 60 Hz36 V·A
at 50 Hz0.8
at 60 Hz0.8
at 50 Hz5.9 V·A
at 60 Hz5.9 V·A
at 50 Hz0.24
at 60 Hz0.24
at AC9 ... 35 ms
at AC4 ... 15 ms
arcing time10 ... 15 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact1
number of NO contacts for auxiliary contacts instantaneous contact0
operational current at AC-12 maximum10 A
at 230 V rated value10 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0.15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0.9 A
at 220 V rated value0.3 A
at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
at 480 V rated value14 A
at 600 V rated value11 A
— at 110/120 V rated value1 hp
— at 230 V rated value2 hp
— at 200/208 V rated value3 hp
— at 220/230 V rated value5 hp
— at 460/480 V rated value10 hp
— at 575/600 V rated value10 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
— with type of coordination 1 requiredgG: 50 A (690 V, 100 kA), aM: 25 A (690 V, 100 kA), BS88: 50 A (415 V, 80 kA)
— with type of coordination 2 requiredgG: 25 A (690 V, 100 kA), aM: 20 A (690 V, 100 kA), BS88: 25 A (415 V, 80 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method side-by-side mountingYes
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height58 mm
width45 mm
depth73 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
for main current circuitscrew-type terminals
for auxiliary and control circuitscrew-type terminals
at contactor for auxiliary contactsScrew-type terminals
of magnet coilscrew terminal
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
— solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm²
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for AWG cables for main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
solid0.5 ... 4 mm²
stranded0.5 ... 4 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
solid or stranded0.5 ... 4 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
— solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
AWG number as coded connectable conductor cross section for main contacts20 ... 12
AWG number as coded connectable conductor cross section for auxiliary contacts20 ... 12
Safety related data
mirror contact according to IEC 60947-4-1Yes
positively driven operation according to IEC 60947-5-1No
suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Approvals Certificates
global warming potential [CO2 eq] / during manufacturing1.18 kg
global warming potential [CO2 eq] / during operation38.5 kg
global warming potential [CO2 eq] / after end of life-0.155 kg
global warming potential [CO2 eq] / total39.6 kg

Related Products

1EE1122-..A00-...4
Siemens 1EE1122-..A00-...4
View Details

Siemens

1EE1122-..A00-...4

MFR #1EE1122-..A00-...4

SKU #YLS3FGFZLYE3EV8

1EE1124-..A00-...4
Siemens 1EE1124-..A00-...4
View Details

Siemens

1EE1124-..A00-...4

MFR #1EE1124-..A00-...4

SKU #YLSKZIN1GEIPRVP

1EE1142-..A00-...4
Siemens 1EE1142-..A00-...4
View Details

Siemens

1EE1142-..A00-...4

MFR #1EE1142-..A00-...4

SKU #YLSUX3MNEZEJGPU

1EE1144-..A00-...4
Siemens 1EE1144-..A00-...4
View Details

Siemens

1EE1144-..A00-...4

MFR #1EE1144-..A00-...4

SKU #YLSD9GON9QOYBAE

1EE1322-....0-...4
Siemens 1EE1322-....0-...4
View Details

Siemens

1EE1322-....0-...4

MFR #1EE1322-....0-...4

SKU #YLSSAVZE8P7OOP6

1EE1322-...00-1..2
Siemens 1EE1322-...00-1..2
View Details

Siemens

1EE1322-...00-1..2

MFR #1EE1322-...00-1..2

SKU #YLSY69IQB2JXAXJ

1EE1322-..A00-...4
Siemens 1EE1322-..A00-...4
View Details

Siemens

1EE1322-..A00-...4

MFR #1EE1322-..A00-...4

SKU #YLSH1E6AJR6XWJF

1EE1324-....0-...4
Siemens 1EE1324-....0-...4
View Details

Siemens

1EE1324-....0-...4

MFR #1EE1324-....0-...4

SKU #YLS8GBB9BXAF83

1EE1324-...00-1..2
Siemens 1EE1324-...00-1..2
View Details

Siemens

1EE1324-...00-1..2

MFR #1EE1324-...00-1..2

SKU #YLSLOS6I1BDXR58

1EE1324-..A00-...4
Siemens 1EE1324-..A00-...4
View Details

Siemens

1EE1324-..A00-...4

MFR #1EE1324-..A00-...4

SKU #YLSE0T3LUEU0CI

Featured Products

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

MXS-AS16L
SMC MXS-AS16L
View Details

SMC

MXS-AS16L

MFR #MXS-AS16L

SKU #YLSAP0XXFGFSWY6

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

Related Searches

Siemens 3RT2018-1AP62 priceSiemens 3RT2018-1AP62 quotebuy Siemens 3RT2018-1AP623RT2018-1AP62 price3RT2018-1AP62 stock availabilitySiemens spare partsSiemens 3RT2018-1AP62 equivalentSiemens 3RT2018-1AP62 specifications