Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3RT2017-2KF42-1LA0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3RT2017-2KF42-1LA0

traction contactor, AC-3e/AC-3, 12 A, 5.5 kW / 400 V, 3-pole, 110 V DC, 0.7-1.25* Uc, with integrated suppressor diode, auxiliary contacts: 1 NC, spring-loaded terminal, frame size: S00, with plugged on series resistor, upright mounting position

SiemensMFR # 3RT2017-2KF42-1LA0SKU # CEY-8EF3B03937E8
product brand nameSIRIUS
product designationPower contactor
design of the productWith extended operating range
product type designation3RT2
size of contactorS00
function module for communicationNo
Share

About This Product

traction contactor, AC-3e/AC-3, 12 A, 5.5 kW / 400 V, 3-pole, 110 V DC, 0.7-1.25* Uc, with integrated suppressor diode, auxiliary contacts: 1 NC, spring-loaded terminal, frame size: S00, with plugged on series resistor, upright mounting position

Siemens 3RT2017-2KF42-1LA0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product designationPower contactor
design of the productWith extended operating range
product type designation3RT2
General technical data
size of contactorS00
function module for communicationNo
auxiliary switchYes
at AC in hot operating state3.6 W
at AC in hot operating state per pole1.2 W
without load current share typical4 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value690 V
of auxiliary circuit with degree of pollution 3 rated value690 V
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
at DC7.3 g / 5 ms, 4.7 g / 10 ms
at DC11,4 g / 5 ms, 7,3g / 10 ms
of contactor typical30 000 000
of the contactor with added electronically optimized auxiliary switch block typical5 000 000
of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2009
Net Weight0.306 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-40 ... +70 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at AC-1 at 400 V at ambient temperature 40 °C rated value22 A
— up to 690 V at ambient temperature 40 °C rated value22 A
— up to 690 V at ambient temperature 60 °C rated value20 A
at AC-2 at 400 V rated value12 A
— at 400 V rated value12 A
— at 500 V rated value9.2 A
— at 690 V rated value6.7 A
— at 400 V rated value12 A
— at 500 V rated value9.2 A
— at 690 V rated value6.7 A
at AC-4 at 400 V rated value8.5 A
at maximum AC-1 rated value4 mm²
at 400 V rated value4.1 A
at 690 V rated value3.3 A
— at 24 V rated value20 A
— at 110 V rated value2.1 A
— at 220 V rated value0.8 A
— at 440 V rated value0.6 A
— at 600 V rated value0.6 A
— at 24 V rated value20 A
— at 110 V rated value12 A
— at 220 V rated value1.6 A
— at 440 V rated value0.8 A
— at 600 V rated value0.7 A
— at 24 V rated value20 A
— at 110 V rated value20 A
— at 220 V rated value20 A
— at 440 V rated value1.3 A
— at 600 V rated value1 A
— at 24 V rated value20 A
— at 110 V rated value0.1 A
— at 24 V rated value20 A
— at 110 V rated value0.35 A
— at 24 V rated value20 A
— at 110 V rated value20 A
— at 220 V rated value1.5 A
— at 440 V rated value0.2 A
— at 600 V rated value0.2 A
at AC-2 at 400 V rated value5.5 kW
— at 230 V rated value3 kW
— at 400 V rated value5.5 kW
— at 500 V rated value5.5 kW
— at 690 V rated value5.5 kW
— at 230 V rated value3 kW
— at 400 V rated value5.5 kW
— at 500 V rated value5.5 kW
— at 690 V rated value5.5 kW
at 400 V rated value2 kW
at 690 V rated value2.5 kW
limited to 1 s switching at zero current maximum200 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum123 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum96 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum74 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum61 A; Use minimum cross-section acc. to AC-1 rated value
at DC1 500 1/h
at AC-2 at AC-3e maximum750 1/h
at AC-4 maximum250 1/h
Control circuit/ Control
type of voltageDC
type of voltage of the control supply voltageDC
control supply voltage at DC rated value110 V
initial value0.7
full-scale value1.25
design of the surge suppressorsuppressor diode
closing power of magnet coil at DC13 W
holding power of magnet coil at DC4 W
at DC25 ... 130 ms
at DC7 ... 20 ms
arcing time10 ... 15 ms
control version of the switch operating mechanismE1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts1
operational current at AC-12 maximum10 A
at 230 V rated value10 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0.15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0.9 A
at 220 V rated value0.3 A
at 600 V rated value0.1 A
UL/CSA ratings
at 480 V rated value11 A
at 600 V rated value11 A
— at 110/120 V rated value0.5 hp
— at 230 V rated value2 hp
— at 200/208 V rated value3 hp
— at 220/230 V rated value3 hp
— at 460/480 V rated value7.5 hp
— at 575/600 V rated value10 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
— with type of coordination 1 requiredgG: 50 A (690 V,100 kA), aM: 20 A (690 V,100 kA), BS88: 35 A (415 V,80 kA)
— with type of coordination 2 requiredgG: 20 A (690 V, 100 kA), aM: 16 A (690 V, 100 kA), BS88: 20 A (415 V, 80 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (690 V, 1 kA)
Installation/ mounting/ dimensions
mounting positionstanding, on horizontal mounting surface
fastening method side-by-side mountingYes
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height70 mm
width45 mm
depth121 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
for main current circuitspring-loaded terminals
for auxiliary and control circuitspring-loaded terminals
at contactor for auxiliary contactsSpring-type terminals
of magnet coilSpring-loaded terminal
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
— solid or stranded2x (0,5 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 2.5 mm²)
— finely stranded without core end processing2x (0.5 ... 2.5 mm²)
for AWG cables for main contacts2x (20 ... 12)
— solid or stranded2x (0,5 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 2.5 mm²)
— finely stranded without core end processing2x (0.5 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 12)
AWG number as coded connectable conductor cross section for main contacts20 ... 12
AWG number as coded connectable conductor cross section for auxiliary contacts20 ... 12
Safety related data
mirror contact according to IEC 60947-4-1Yes
positively driven operation according to IEC 60947-5-1No
suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Communication/ Protocol
product function bus communicationNo
Approvals Certificates
global warming potential [CO2 eq] / during manufacturing1.42 kg
global warming potential [CO2 eq] / during operation152 kg
global warming potential [CO2 eq] / after end of life-0.305 kg
global warming potential [CO2 eq] / total153 kg

Accessories 7

Genuine accessories that can be used with the Siemens 3RT2017-2KF42-1LA0 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
3RT2916-1GA00Aksesuar · Additional load modules · additional load modules
3RT2916-1PA1Aksesuar · EMC suppression modules · EMC suppression modules
3RT2916-1PA2Aksesuar · EMC suppression modules · EMC suppression modules
3RT2916-1PA3Aksesuar · EMC suppression modules · EMC suppression modules
3RT2916-1PB1Aksesuar · EMC suppression modules · EMC suppression modules
3RT2916-1PB2Aksesuar · EMC suppression modules · EMC suppression modules
3RT2916-1PB3Aksesuar · EMC suppression modules · EMC suppression modules

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

MXS-AS16L
SMC MXS-AS16L
View Details

SMC

MXS-AS16L

MFR #MXS-AS16L

SKU #YLSAP0XXFGFSWY6

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
View Details

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
View Details

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

Related Searches

Siemens 3RT2017-2KF42-1LA0 priceSiemens 3RT2017-2KF42-1LA0 quotebuy Siemens 3RT2017-2KF42-1LA03RT2017-2KF42-1LA0 price3RT2017-2KF42-1LA0 stock availabilitySiemens spare partsSiemens 3RT2017-2KF42-1LA0 equivalentSiemens 3RT2017-2KF42-1LA0 specifications