power contactor, AC-3e/AC-3, 9 A, 4 kW / 400 V, 3-pole, 230 V AC, 50/60 Hz, auxiliary contacts: 1 NC, spring-loaded terminal, size: S00, multi-unit packaging, pack = 60 units

SiemensMFR # 3RT2016-2AP02-ZW96SKU # CEY-8EF3B0393322
product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
size of contactorS00
function module for communicationNo
auxiliary switchYes
Share

About This Product

power contactor, AC-3e/AC-3, 9 A, 4 kW / 400 V, 3-pole, 230 V AC, 50/60 Hz, auxiliary contacts: 1 NC, spring-loaded terminal, size: S00, multi-unit packaging, pack = 60 units

Siemens 3RT2016-2AP02-ZW96

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
General technical data
size of contactorS00
function module for communicationNo
auxiliary switchYes
at AC in hot operating state0.9 W
at AC in hot operating state per pole0.3 W
without load current share typical1.1 W
type of calculation of power loss current-dependentquadratic
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
at AC6,7 g / 5 ms, 4,2 g / 10 ms
at AC10,5 g / 5 ms, 6,6 g / 10 ms
of contactor typical30 000 000
of the contactor with added electronically optimized auxiliary switch block typical5 000 000
of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2009
Net Weight0.25 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at AC-1 at 400 V at ambient temperature 40 °C rated value22 A
— up to 690 V at ambient temperature 40 °C rated value22 A
— up to 690 V at ambient temperature 60 °C rated value20 A
— at 400 V rated value9 A
— at 500 V rated value7.7 A
— at 690 V rated value6.7 A
— at 400 V rated value9 A
— at 500 V rated value7.7 A
— at 690 V rated value6.7 A
at AC-4 at 400 V rated value8.5 A
at AC-5a up to 690 V rated value19.4 A
at AC-5b up to 400 V rated value7.4 A
— up to 230 V for current peak value n=20 rated value5.3 A
— up to 400 V for current peak value n=20 rated value5.3 A
— up to 500 V for current peak value n=20 rated value5.3 A
— up to 690 V for current peak value n=20 rated value5 A
— up to 230 V for current peak value n=30 rated value3.5 A
— up to 400 V for current peak value n=30 rated value3.5 A
— up to 500 V for current peak value n=30 rated value3.6 A
— up to 690 V for current peak value n=30 rated value3.3 A
minimum cross-section in main circuit at maximum AC-1 rated value4 mm²
at 400 V rated value4.1 A
at 690 V rated value3.3 A
— at 24 V rated value20 A
— at 60 V rated value20 A
— at 110 V rated value2.1 A
— at 220 V rated value0.8 A
— at 440 V rated value0.6 A
— at 600 V rated value0.6 A
— at 24 V rated value20 A
— at 60 V rated value20 A
— at 110 V rated value12 A
— at 220 V rated value1.6 A
— at 440 V rated value0.8 A
— at 600 V rated value0.7 A
— at 24 V rated value20 A
— at 60 V rated value20 A
— at 110 V rated value20 A
— at 220 V rated value20 A
— at 440 V rated value1.3 A
— at 600 V rated value1 A
— at 24 V rated value20 A
— at 60 V rated value0.5 A
— at 110 V rated value0.15 A
— at 24 V rated value20 A
— at 60 V rated value5 A
— at 110 V rated value0.35 A
— at 24 V rated value20 A
— at 60 V rated value20 A
— at 110 V rated value20 A
— at 220 V rated value1.5 A
— at 440 V rated value0.2 A
— at 600 V rated value0.2 A
at AC-2 at 400 V rated value4 kW
— at 230 V rated value2.2 kW
— at 400 V rated value4 kW
— at 500 V rated value4 kW
— at 690 V rated value5.5 kW
— at 230 V rated value2.2 kW
— at 400 V rated value4 kW
— at 500 V rated value4 kW
— at 690 V rated value5.5 kW
at 400 V rated value2 kW
at 690 V rated value2.5 kW
up to 230 V for current peak value n=20 rated value2 kVA
up to 400 V for current peak value n=20 rated value3.6 kVA
up to 500 V for current peak value n=20 rated value4.6 kVA
up to 690 V for current peak value n=20 rated value5.9 kVA
up to 230 V for current peak value n=30 rated value1.3 kVA
up to 400 V for current peak value n=30 rated value2.4 kVA
up to 500 V for current peak value n=30 rated value3.1 kVA
up to 690 V for current peak value n=30 rated value4 kVA
limited to 1 s switching at zero current maximum155 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum111 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum86 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum66 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum55 A; Use minimum cross-section acc. to AC-1 rated value
at AC10 000 1/h
at AC-1 maximum1 000 1/h
at AC-2 maximum750 1/h
at AC-3 maximum750 1/h
— maximum750 1/h
at AC-4 maximum250 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC
at 50 Hz rated value230 V
at 60 Hz rated value230 V
at 50 Hz0.8 ... 1.1
at 60 Hz0.85 ... 1.1
at 50 Hz27 V·A
at 60 Hz24.3 V·A
at 50 Hz0.8
at 60 Hz0.75
at 50 Hz4.2 V·A
at 60 Hz3.3 V·A
at 50 Hz0.25
at 60 Hz0.25
at AC9 ... 35 ms
at AC4 ... 15 ms
arcing time10 ... 15 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact1
number of NO contacts for auxiliary contacts instantaneous contact0
operational current at AC-12 maximum10 A
at 230 V rated value10 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0.15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0.9 A
at 220 V rated value0.3 A
at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
at 480 V rated value7.6 A
at 600 V rated value9 A
— at 110/120 V rated value0.33 hp
— at 230 V rated value1 hp
— at 200/208 V rated value2 hp
— at 220/230 V rated value3 hp
— at 460/480 V rated value5 hp
— at 575/600 V rated value7.5 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
— with type of coordination 1 requiredgG: 35 A (690 V,100 kA), aM: 20 A (690 V,100 kA), BS88: 35 A (415 V,80 kA)
— with type of coordination 2 requiredgG: 20 A (690 V, 100 kA), aM: 16 A (690 V, 100 kA), BS88: 20 A (415 V, 80 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method side-by-side mountingYes
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height70 mm
width45 mm
depth73 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
for main current circuitspring-loaded terminals
for auxiliary and control circuitspring-loaded terminals
at contactor for auxiliary contactsSpring-type terminals
of magnet coilSpring-loaded terminal
— solid2x (0.5 ... 4 mm²)
— solid or stranded2x (0,5 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 2.5 mm²)
— finely stranded without core end processing2x (0.5 ... 2.5 mm²)
for AWG cables for main contacts2x (20 ... 12)
solid0.5 ... 4 mm²
stranded0.5 ... 4 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
finely stranded without core end processing0.5 ... 2.5 mm²
solid or stranded0.5 ... 4 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
finely stranded without core end processing0.5 ... 2.5 mm²
— solid or stranded2x (0,5 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 2.5 mm²)
— finely stranded without core end processing2x (0.5 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 12)
AWG number as coded connectable conductor cross section for main contacts20 ... 12
AWG number as coded connectable conductor cross section for auxiliary contacts20 ... 12
Safety related data
mirror contact according to IEC 60947-4-1Yes
positively driven operation according to IEC 60947-5-1No
suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front

Related Products

1EE1122-..A00-...4
Siemens 1EE1122-..A00-...4
View Details

Siemens

1EE1122-..A00-...4

MFR #1EE1122-..A00-...4

SKU #YLS3FGFZLYE3EV8

1EE1124-..A00-...4
Siemens 1EE1124-..A00-...4
View Details

Siemens

1EE1124-..A00-...4

MFR #1EE1124-..A00-...4

SKU #YLSKZIN1GEIPRVP

1EE1142-..A00-...4
Siemens 1EE1142-..A00-...4
View Details

Siemens

1EE1142-..A00-...4

MFR #1EE1142-..A00-...4

SKU #YLSUX3MNEZEJGPU

1EE1144-..A00-...4
Siemens 1EE1144-..A00-...4
View Details

Siemens

1EE1144-..A00-...4

MFR #1EE1144-..A00-...4

SKU #YLSD9GON9QOYBAE

1EE1322-....0-...4
Siemens 1EE1322-....0-...4
View Details

Siemens

1EE1322-....0-...4

MFR #1EE1322-....0-...4

SKU #YLSSAVZE8P7OOP6

1EE1322-...00-1..2
Siemens 1EE1322-...00-1..2
View Details

Siemens

1EE1322-...00-1..2

MFR #1EE1322-...00-1..2

SKU #YLSY69IQB2JXAXJ

1EE1322-..A00-...4
Siemens 1EE1322-..A00-...4
View Details

Siemens

1EE1322-..A00-...4

MFR #1EE1322-..A00-...4

SKU #YLSH1E6AJR6XWJF

1EE1324-....0-...4
Siemens 1EE1324-....0-...4
View Details

Siemens

1EE1324-....0-...4

MFR #1EE1324-....0-...4

SKU #YLS8GBB9BXAF83

1EE1324-...00-1..2
Siemens 1EE1324-...00-1..2
View Details

Siemens

1EE1324-...00-1..2

MFR #1EE1324-...00-1..2

SKU #YLSLOS6I1BDXR58

1EE1324-..A00-...4
Siemens 1EE1324-..A00-...4
View Details

Siemens

1EE1324-..A00-...4

MFR #1EE1324-..A00-...4

SKU #YLSE0T3LUEU0CI

Featured Products

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
View Details

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
View Details

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

Related Searches

Siemens 3RT2016-2AP02-ZW96 priceSiemens 3RT2016-2AP02-ZW96 quotebuy Siemens 3RT2016-2AP02-ZW963RT2016-2AP02-ZW96 price3RT2016-2AP02-ZW96 stock availabilitySiemens spare partsSiemens 3RT2016-2AP02-ZW96 equivalentSiemens 3RT2016-2AP02-ZW96 specifications