Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3RT2015-2AP01-ZW97

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3RT2015-2AP01-ZW97

power contactor, AC-3e/AC-3, 7 A, 3 kW / 400 V, 3-pole, 230 V AC, 50/60 Hz, auxiliary contacts: 1 NO, spring-loaded terminal, size: S00, multi-unit packaging, pack = 32 units

SiemensMFR # 3RT2015-2AP01-ZW97SKU # CEY-8EF3B0393DE7
product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
size of contactorS00
function module for communicationNo
auxiliary switchYes
Share

About This Product

power contactor, AC-3e/AC-3, 7 A, 3 kW / 400 V, 3-pole, 230 V AC, 50/60 Hz, auxiliary contacts: 1 NO, spring-loaded terminal, size: S00, multi-unit packaging, pack = 32 units

Siemens 3RT2015-2AP01-ZW97

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
General technical data
size of contactorS00
function module for communicationNo
auxiliary switchYes
at AC in hot operating state0.6 W
at AC in hot operating state per pole0.2 W
without load current share typical1.1 W
type of calculation of power loss current-dependentquadratic
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
at AC6,7 g / 5 ms, 4,2 g / 10 ms
at AC10,5 g / 5 ms, 6,6 g / 10 ms
of contactor typical30 000 000
of the contactor with added electronically optimized auxiliary switch block typical5 000 000
of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2009
Net Weight0.235 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at AC-1 at 400 V at ambient temperature 40 °C rated value18 A
— up to 690 V at ambient temperature 40 °C rated value18 A
— up to 690 V at ambient temperature 60 °C rated value16 A
— at 400 V rated value7 A
— at 500 V rated value6 A
— at 690 V rated value4.9 A
— at 400 V rated value7 A
— at 500 V rated value6 A
— at 690 V rated value4.9 A
at AC-4 at 400 V rated value6.5 A
at AC-5a up to 690 V rated value15.8 A
at AC-5b up to 400 V rated value5.8 A
— up to 230 V for current peak value n=20 rated value4 A
— up to 400 V for current peak value n=20 rated value4 A
— up to 500 V for current peak value n=20 rated value3.8 A
— up to 690 V for current peak value n=20 rated value3.6 A
— up to 230 V for current peak value n=30 rated value2.7 A
— up to 400 V for current peak value n=30 rated value2.7 A
— up to 500 V for current peak value n=30 rated value2.5 A
— up to 690 V for current peak value n=30 rated value2.4 A
minimum cross-section in main circuit at maximum AC-1 rated value2.5 mm²
at 400 V rated value2.6 A
at 690 V rated value1.8 A
— at 24 V rated value15 A
— at 60 V rated value15 A
— at 110 V rated value1.5 A
— at 220 V rated value0.6 A
— at 440 V rated value0.42 A
— at 600 V rated value0.42 A
— at 24 V rated value15 A
— at 60 V rated value15 A
— at 110 V rated value8.4 A
— at 220 V rated value1.2 A
— at 440 V rated value0.6 A
— at 600 V rated value0.5 A
— at 24 V rated value15 A
— at 60 V rated value15 A
— at 110 V rated value15 A
— at 220 V rated value15 A
— at 440 V rated value0.9 A
— at 600 V rated value0.7 A
— at 24 V rated value15 A
— at 60 V rated value0.35 A
— at 110 V rated value0.1 A
— at 24 V rated value15 A
— at 60 V rated value3.5 A
— at 110 V rated value0.25 A
— at 24 V rated value15 A
— at 60 V rated value15 A
— at 110 V rated value15 A
— at 220 V rated value1.2 A
— at 440 V rated value0.14 A
— at 600 V rated value0.14 A
at AC-2 at 400 V rated value3 kW
— at 230 V rated value1.5 kW
— at 400 V rated value3 kW
— at 500 V rated value3 kW
— at 690 V rated value4 kW
— at 230 V rated value1.5 kW
— at 400 V rated value3 kW
— at 500 V rated value3 kW
— at 690 V rated value4 kW
at 400 V rated value1.15 kW
at 690 V rated value1.15 kW
up to 230 V for current peak value n=20 rated value1.5 kVA
up to 400 V for current peak value n=20 rated value2.7 kVA
up to 500 V for current peak value n=20 rated value3.3 kVA
up to 690 V for current peak value n=20 rated value4.3 kVA
up to 230 V for current peak value n=30 rated value1 kVA
up to 400 V for current peak value n=30 rated value1.8 kVA
up to 500 V for current peak value n=30 rated value2.2 kVA
up to 690 V for current peak value n=30 rated value2.9 kVA
limited to 1 s switching at zero current maximum120 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum86 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum67 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum52 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum43 A; Use minimum cross-section acc. to AC-1 rated value
at AC10 000 1/h
at AC-1 maximum1 000 1/h
at AC-2 maximum750 1/h
at AC-3 maximum750 1/h
— maximum750 1/h
at AC-4 maximum250 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC
at 50 Hz rated value230 V
at 60 Hz rated value230 V
at 50 Hz0.8 ... 1.1
at 60 Hz0.85 ... 1.1
at 50 Hz27 V·A
at 60 Hz24.3 V·A
at 50 Hz0.8
at 60 Hz0.75
at 50 Hz4.2 V·A
at 60 Hz3.3 V·A
at 50 Hz0.25
at 60 Hz0.25
at AC9 ... 35 ms
at AC4 ... 15 ms
arcing time10 ... 15 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact0
number of NO contacts for auxiliary contacts instantaneous contact1
operational current at AC-12 maximum10 A
at 230 V rated value10 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0.15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0.9 A
at 220 V rated value0.3 A
at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
at 480 V rated value4.8 A
at 600 V rated value6.1 A
— at 110/120 V rated value0.25 hp
— at 230 V rated value0.75 hp
— at 200/208 V rated value1.5 hp
— at 220/230 V rated value2 hp
— at 460/480 V rated value3 hp
— at 575/600 V rated value5 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
— with type of coordination 1 requiredgG: 35 A (690 V,100 kA), aM: 20 A (690 V,100 kA), BS88: 35 A (415 V,80 kA)
— with type of coordination 2 requiredgG: 20 A (690 V, 100 kA), aM: 16 A (690 V, 100 kA), BS88: 20 A (415 V, 80 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method side-by-side mountingYes
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height70 mm
width45 mm
depth73 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
for main current circuitspring-loaded terminals
for auxiliary and control circuitspring-loaded terminals
at contactor for auxiliary contactsSpring-type terminals
of magnet coilSpring-loaded terminal
— solid2x (0.5 ... 4 mm²)
— solid or stranded2x (0,5 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 2.5 mm²)
— finely stranded without core end processing2x (0.5 ... 2.5 mm²)
for AWG cables for main contacts2x (20 ... 12)
solid0.5 ... 4 mm²
stranded0.5 ... 4 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
finely stranded without core end processing0.5 ... 2.5 mm²
solid or stranded0.5 ... 4 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
finely stranded without core end processing0.5 ... 2.5 mm²
— solid or stranded2x (0,5 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 2.5 mm²)
— finely stranded without core end processing2x (0.5 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 12)
AWG number as coded connectable conductor cross section for main contacts20 ... 12
AWG number as coded connectable conductor cross section for auxiliary contacts20 ... 12
Safety related data
mirror contact according to IEC 60947-4-1Yes; with 3RH29
positively driven operation according to IEC 60947-5-1No
suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
View Details

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
View Details

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
View Details

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

Related Searches

Siemens 3RT2015-2AP01-ZW97 priceSiemens 3RT2015-2AP01-ZW97 quotebuy Siemens 3RT2015-2AP01-ZW973RT2015-2AP01-ZW97 price3RT2015-2AP01-ZW97 stock availabilitySiemens spare partsSiemens 3RT2015-2AP01-ZW97 equivalentSiemens 3RT2015-2AP01-ZW97 specifications