Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3RT1076-6SF36-3PA0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3RT1076-6SF36-3PA0

power contactor, AC-3e/AC-3 500 A, 250 kW / 400 V AC (50-60 Hz) / DC 96-127 V x (0.8-1.1) F-PLC input 24 V DC 3-pole, auxiliary contacts 2 NO + 2 NC permanently mounted drive: electronic main circuit: busbar control and auxiliary circuit: screw terminal

SiemensMFR # 3RT1076-6SF36-3PA0SKU # YLSSUBABRUYJ8AZ
product brand nameSIRIUS
product designationPower contactor
product type designation3RT1
size of contactorS12
function module for communicationNo
auxiliary switchYes
Share

About This Product

power contactor, AC-3e/AC-3 500 A, 250 kW / 400 V AC (50-60 Hz) / DC 96-127 V x (0.8-1.1) F-PLC input 24 V DC 3-pole, auxiliary contacts 2 NO + 2 NC permanently mounted drive: electronic main circuit: busbar control and auxiliary circuit: screw terminal

Siemens 3RT1076-6SF36-3PA0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product designationPower contactor
product type designation3RT1
General technical data
size of contactorS12
function module for communicationNo
auxiliary switchYes
at AC in hot operating state165 W
at AC in hot operating state per pole55 W
without load current share typical3.6 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value1 000 V
of auxiliary circuit with degree of pollution 3 rated value500 V
of main circuit rated value8 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1690 V
at AC8,5 g / 5 ms, 4,2 g / 10 ms
at DC8,5 g / 5 ms, 4,2 g / 10 ms
at AC13,4 g / 5 ms, 6,5 g / 10 ms
at DC13,4 g / 5 ms, 6,5 g / 10 ms
of contactor typical10 000 000
of the contactor with added electronically optimized auxiliary switch block typical5 000 000
of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)03/01/2017
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1
Net Weight10.419 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum1 000 V
at AC-3e rated value maximum1 000 V
at AC-1 at 400 V at ambient temperature 40 °C rated value610 A
— up to 690 V at ambient temperature 40 °C rated value610 A
— up to 690 V at ambient temperature 60 °C rated value550 A
— up to 1000 V at ambient temperature 40 °C rated value200 A
— up to 1000 V at ambient temperature 60 °C rated value200 A
— at 400 V rated value500 A
— at 500 V rated value500 A
— at 690 V rated value450 A
— at 1000 V rated value180 A
— at 400 V rated value500 A
— at 500 V rated value500 A
— at 690 V rated value450 A
— at 1000 V rated value180 A
at AC-4 at 400 V rated value430 A
at AC-5a up to 690 V rated value536 A
at AC-5b up to 400 V rated value415 A
— up to 230 V for current peak value n=20 rated value414 A
— up to 400 V for current peak value n=20 rated value414 A
— up to 500 V for current peak value n=20 rated value414 A
— up to 690 V for current peak value n=20 rated value414 A
— up to 1000 V for current peak value n=20 rated value180 A
— up to 230 V for current peak value n=30 rated value276 A
— up to 400 V for current peak value n=30 rated value276 A
— up to 500 V for current peak value n=30 rated value276 A
— up to 690 V for current peak value n=30 rated value276 A
— up to 1000 V for current peak value n=30 rated value180 A
minimum cross-section in main circuit at maximum AC-1 rated value370 mm²
at 400 V rated value175 A
at 690 V rated value150 A
— at 24 V rated value400 A
— at 60 V rated value330 A
— at 110 V rated value33 A
— at 220 V rated value3.8 A
— at 440 V rated value0.9 A
— at 600 V rated value0.6 A
— at 24 V rated value400 A
— at 60 V rated value400 A
— at 110 V rated value400 A
— at 220 V rated value400 A
— at 440 V rated value4 A
— at 600 V rated value2 A
— at 24 V rated value400 A
— at 60 V rated value400 A
— at 110 V rated value400 A
— at 220 V rated value400 A
— at 440 V rated value11 A
— at 600 V rated value5.2 A
— at 24 V rated value400 A
— at 60 V rated value11 A
— at 110 V rated value3 A
— at 220 V rated value0.6 A
— at 440 V rated value0.18 A
— at 600 V rated value0.125 A
— at 24 V rated value400 A
— at 60 V rated value400 A
— at 110 V rated value400 A
— at 220 V rated value2.5 A
— at 440 V rated value0.65 A
— at 600 V rated value0.37 A
— at 24 V rated value400 A
— at 60 V rated value400 A
— at 110 V rated value400 A
— at 220 V rated value400 A
— at 440 V rated value1.4 A
— at 600 V rated value0.75 A
at AC-2 at 400 V rated value250 kW
— at 230 V rated value160 kW
— at 400 V rated value250 kW
— at 500 V rated value315 kW
— at 690 V rated value400 kW
— at 1000 V rated value250 kW
— at 230 V rated value160 kW
— at 400 V rated value250 kW
— at 500 V rated value315 kW
— at 690 V rated value400 kW
— at 1000 V rated value250 kW
at 400 V rated value98 kW
at 690 V rated value148 kW
up to 230 V for current peak value n=20 rated value160 kVA
up to 400 V for current peak value n=20 rated value280 kVA
up to 500 V for current peak value n=20 rated value350 kVA
up to 690 V for current peak value n=20 rated value490 kVA
up to 1000 V for current peak value n=20 rated value310 kVA
up to 230 V for current peak value n=30 rated value110 kVA
up to 400 V for current peak value n=30 rated value190 kVA
up to 500 V for current peak value n=30 rated value230 kVA
up to 690 V for current peak value n=30 rated value330 kVA
up to 1000 V for current peak value n=30 rated value310 kVA
limited to 1 s switching at zero current maximum7 484 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum7 484 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum5 978 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum3 765 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum2 887 A; Use minimum cross-section acc. to AC-1 rated value
at AC500 1/h
at DC500 1/h
at AC-1 maximum200 1/h
at AC-2 maximum170 1/h
at AC-3 maximum200 1/h
— maximum200 1/h
at AC-4 maximum130 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
at 50 Hz rated value96 ... 127 V
at 60 Hz rated value96 ... 127 V
control supply voltage at DC rated value96 ... 127 V
initial value0.8
full-scale value1.1
at 50 Hz0.8 ... 1.1
at 60 Hz0.8 ... 1.1
type of PLC-control input according to IEC 60947-1Type 1
consumed current at PLC-control input according to IEC 60947-1 maximum14 mA
voltage at PLC-control input rated value24 V
operating range factor of the voltage at PLC-control input0.8 ... 1.1
design of the surge suppressorwith varistor
— at 50 Hz560 V·A
— at 60 Hz560 V·A
— at 60 Hz750 V·A
— at 50 Hz750 V·A
at 50 Hz750 V·A
at 60 Hz750 V·A
at 50 Hz0.8
at 60 Hz0.8
at minimum rated control supply voltage at DC3 V·A
at maximum rated control supply voltage at DC3.6 V·A
— at 50 Hz5.6 V·A
— at 60 Hz5.6 V·A
— at 50 Hz9 V·A
— at 60 Hz9 V·A
at 50 Hz0.5
at 60 Hz0.4
closing power of magnet coil at DC800 W
holding power of magnet coil at DC3.6 W
at AC60 ... 75 ms
at DC60 ... 75 ms
at AC115 ... 130 ms
at DC115 ... 130 ms
recovery time after power failure typical2 s
arcing time10 ... 15 ms
control version of the switch operating mechanismFail-safe PLC input (F-PLC-IN)
Auxiliary circuit
design of the auxiliary switchlateral, permanently connected
number of NC contacts for auxiliary contacts instantaneous contact2
number of NO contacts for auxiliary contacts instantaneous contact2
operational current at AC-12 maximum10 A
at 230 V rated value6 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0.15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0.9 A
at 220 V rated value0.3 A
at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
at 480 V rated value477 A
at 600 V rated value472 A
— at 200/208 V rated value150 hp
— at 220/230 V rated value200 hp
— at 460/480 V rated value400 hp
— at 575/600 V rated value500 hp
contact rating of auxiliary contacts according to ULA600 / P600
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
— with type of coordination 1 requiredgG: 630 A (690 V, 100 kA)
— with type of coordination 2 requiredgG: 500 A (690 V, 100 kA), aM: 500 A (690 V, 50 kA), BS88: 500 A (415 V, 50 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
fastening method side-by-side mountingYes
fastening methodscrew fixing
height214 mm
width160 mm
depth225 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards20 mm
— upwards10 mm
— at the side10 mm
— downwards10 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
Connections/ Terminals
for main current circuitConnection bar
for auxiliary and control circuitscrew-type terminals
at contactor for auxiliary contactsScrew-type terminals
of magnet coilscrew terminal
width of connection bar25 mm
thickness of connection bar6 mm
diameter of holes11 mm
number of holes1
for AWG cables for main contacts2/0 ... 500 kcmil
stranded70 ... 240 mm²
solid or stranded0.5 ... 4 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
— solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 1x 12
AWG number as coded connectable conductor cross section for auxiliary contacts18 ... 14
Safety related data
mirror contact according to IEC 60947-4-1Yes
positively driven operation according to IEC 60947-5-1No
suitable for safety functionYes
suitability for use safety-related switching OFFYes
safe stateoff
test wear-related service life necessaryYes
stop category according to IEC 60204-10
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
MTBF75 a
IEC 62061
Safety Integrity Level (SIL) according to IEC 62061SIL 2
PFHD with high demand rate according to IEC 620614.5E-7 1/h
ISO 13849
performance level (PL) according to ISO 13849-1PL c
category according to ISO 13849-12
device type according to ISO 13849-11
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
Safety Integrity Level (SIL) according to IEC 615082
safety device type according to IEC 61508-2Type B
PFHD with high demand rate according to IEC 615084.5E-7 1/h
PFDavg with low demand rate according to IEC 615080.007
Safe failure fraction (SFF)93 %
hardware fault tolerance according to IEC 615080
T1 value of service life according to IEC 6150820 a
Electrical Safety
protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with box terminal/cover

Accessories 36

Genuine accessories that can be used with the Siemens 3RT1076-6SF36-3PA0 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
3RA1954-2AAksesuar · Mechanical interlocks · mechanical interlocks
3RT1926-4MA10Aksesuar · Sealing covers · sealing covers
3RT1955-4PA00Aksesuar · Terminal covers · connection methods
3RT1956-1CC00Aksesuar · Surge suppressor · RC elements
3RT2900-1SB60Aksesuar · Miscellaneous accessories · labeling plates
3RT2926-1QT00Aksesuar · LED modules · LED display indicator modules
3RT1966-4BA31Aksesuar · Wiring modules, connectors and kits · coil connectors
3RT1966-4EA2Aksesuar · Terminal covers · terminal covers
3RT1966-4EA3Aksesuar · Terminal covers · terminal covers
3TX6546-3BAksesuar · Terminal covers · terminal covers
3RT1916-4JA02Aksesuar · Miscellaneous accessories · insulation stops
3RT2900-1SB20Aksesuar · Miscellaneous accessories · labeling plates
3RH1921-1XA22-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RA1972-2AAksesuar · Base plates · base plates
3RA1972-2EAksesuar · Base plates · base plates
3RA1972-2FAksesuar · Base plates · base plates
3RA1973-2AAksesuar · Wiring modules, connectors and kits · link rails
3RA1973-2BAksesuar · Wiring modules, connectors and kits · link rails
3RA1973-3EAksesuar · Wiring modules, connectors and kits · link rails
3RT1966-4EA1Aksesuar · Terminal covers · terminal covers
3RH1921-1CA01Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1CA10Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1CD01Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1CD10Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1DA11Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1EA02Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1EA11Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1EA20Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1JA11Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1KA02Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1KA11Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1KA20Aksesuar · Auxiliary switch · auxiliary switches
3RT2900-1SB10Aksesuar · Miscellaneous accessories · labeling plates
3RT1976-6AYedek parça · Contact pieces and vacuum interrupters · contacts
3RT1976-7AYedek parça · Arc chutes · arc chutes
3RT1955-4NQ02Yedek parça · Terminal covers · plugs

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

CG5EN50SV-150
SMC CG5EN50SV-150
View Details

SMC

CG5EN50SV-150

MFR #CG5EN50SV-150

SKU #YLST11TLVYPVP7H

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
View Details

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

Related Searches

Siemens 3RT1076-6SF36-3PA0 priceSiemens 3RT1076-6SF36-3PA0 quotebuy Siemens 3RT1076-6SF36-3PA03RT1076-6SF36-3PA0 price3RT1076-6SF36-3PA0 stock availabilitySiemens spare partsSiemens 3RT1076-6SF36-3PA0 equivalentSiemens 3RT1076-6SF36-3PA0 specifications