Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3RT1065-6LA06

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3RT1065-6LA06

power contactor, AC-3e/AC-3 265 A, 132 kW / 400 V without operating mechanism 3-pole, auxiliary contacts 2 NO + 2 NC main circuit: busbar control and auxiliary circuit: screw terminal

SiemensMFR # 3RT1065-6LA06SKU # CEY-8EF3B0393BA4
product brand nameSIRIUS
product designationPower contactor
product type designation3RT1
size of contactorS10
function module for communicationNo
auxiliary switchYes
Share

About This Product

power contactor, AC-3e/AC-3 265 A, 132 kW / 400 V without operating mechanism 3-pole, auxiliary contacts 2 NO + 2 NC main circuit: busbar control and auxiliary circuit: screw terminal

Siemens 3RT1065-6LA06

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product designationPower contactor
product type designation3RT1
General technical data
size of contactorS10
function module for communicationNo
auxiliary switchYes
at AC in hot operating state54 W
at AC in hot operating state per pole18 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value1 000 V
of auxiliary circuit with degree of pollution 3 rated value500 V
of main circuit rated value8 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1690 V
at AC8,5 g / 5 ms, 4,2 g / 10 ms
at DC8,5 g / 5 ms, 4,2 g / 10 ms
at AC13,4 g / 5 ms, 6,5 g / 10 ms
at DC13,4 g / 5 ms, 6,5 g / 10 ms
of contactor typical10 000 000
of the contactor with added electronically optimized auxiliary switch block typical5 000 000
of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)05/01/2012
SVHC substance nameLead CAS-No. 7439-92-1
Net Weight5.522 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum1 000 V
at AC-3e rated value maximum1 000 V
at AC-1 at 400 V at ambient temperature 40 °C rated value330 A
— up to 690 V at ambient temperature 40 °C rated value330 A
— up to 690 V at ambient temperature 60 °C rated value300 A
— up to 1000 V at ambient temperature 40 °C rated value150 A
— up to 1000 V at ambient temperature 60 °C rated value150 A
— at 400 V rated value265 A
— at 500 V rated value265 A
— at 690 V rated value265 A
— at 1000 V rated value95 A
— at 400 V rated value265 A
— at 500 V rated value265 A
— at 690 V rated value265 A
— at 1000 V rated value95 A
at AC-4 at 400 V rated value230 A
at AC-5a up to 690 V rated value290 A
at AC-5b up to 400 V rated value219 A
— up to 230 V for current peak value n=20 rated value265 A
— up to 400 V for current peak value n=20 rated value265 A
— up to 500 V for current peak value n=20 rated value265 A
— up to 690 V for current peak value n=20 rated value265 A
— up to 1000 V for current peak value n=20 rated value95 A
— up to 230 V for current peak value n=30 rated value184 A
— up to 400 V for current peak value n=30 rated value184 A
— up to 500 V for current peak value n=30 rated value184 A
— up to 690 V for current peak value n=30 rated value184 A
— up to 1000 V for current peak value n=30 rated value95 A
minimum cross-section in main circuit at maximum AC-1 rated value185 mm²
at 400 V rated value117 A
at 690 V rated value105 A
— at 24 V rated value300 A
— at 60 V rated value300 A
— at 110 V rated value33 A
— at 220 V rated value3.8 A
— at 440 V rated value0.9 A
— at 600 V rated value0.6 A
— at 24 V rated value300 A
— at 60 V rated value300 A
— at 110 V rated value300 A
— at 220 V rated value300 A
— at 440 V rated value4 A
— at 600 V rated value2 A
— at 24 V rated value300 A
— at 60 V rated value300 A
— at 110 V rated value300 A
— at 220 V rated value300 A
— at 440 V rated value11 A
— at 600 V rated value5.2 A
— at 24 V rated value300 A
— at 60 V rated value11 A
— at 110 V rated value3 A
— at 220 V rated value0.6 A
— at 440 V rated value0.18 A
— at 600 V rated value0.125 A
— at 24 V rated value300 A
— at 60 V rated value300 A
— at 110 V rated value300 A
— at 220 V rated value2.5 A
— at 440 V rated value0.65 A
— at 600 V rated value0.37 A
— at 24 V rated value300 A
— at 60 V rated value300 A
— at 110 V rated value300 A
— at 220 V rated value300 A
— at 440 V rated value1.4 A
— at 600 V rated value0.75 A
— at 230 V rated value75 kW
— at 400 V rated value132 kW
— at 500 V rated value160 kW
— at 690 V rated value250 kW
— at 1000 V rated value132 kW
— at 230 V rated value75 kW
— at 400 V rated value132 kW
— at 500 V rated value160 kW
— at 690 V rated value250 kW
— at 1000 V rated value132 kW
at 400 V rated value66 kW
at 690 V rated value102 kW
up to 230 V for current peak value n=20 rated value100 kVA
up to 400 V for current peak value n=20 rated value180 kVA
up to 500 V for current peak value n=20 rated value220 kVA
up to 690 V for current peak value n=20 rated value310 kVA
up to 1000 V for current peak value n=20 rated value160 kVA
up to 230 V for current peak value n=30 rated value70 kVA
up to 400 V for current peak value n=30 rated value120 kVA
up to 500 V for current peak value n=30 rated value150 kVA
up to 690 V for current peak value n=30 rated value220 kVA
up to 1000 V for current peak value n=30 rated value160 kVA
limited to 1 s switching at zero current maximum4 880 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum4 045 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum2 785 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum1 664 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum1 276 A; Use minimum cross-section acc. to AC-1 rated value
at AC2 000 1/h
at DC2 000 1/h
at AC-1 maximum800 1/h
at AC-2 maximum250 1/h
at AC-3 maximum500 1/h
— maximum500 1/h
at AC-4 maximum130 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
at AC30 ... 95 ms
at DC30 ... 95 ms
at AC40 ... 80 ms
at DC40 ... 80 ms
arcing time10 ... 15 ms
control version of the switch operating mechanismWithout operating mechanism
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact2
number of NO contacts for auxiliary contacts instantaneous contact2
operational current at AC-12 maximum10 A
at 230 V rated value6 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0.15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0.9 A
at 220 V rated value0.3 A
at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
at 480 V rated value240 A
at 600 V rated value242 A
— at 200/208 V rated value75 hp
— at 220/230 V rated value100 hp
— at 460/480 V rated value200 hp
— at 575/600 V rated value250 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
— with type of coordination 1 requiredgG: 500 A (690 V, 100 kA)
— with type of coordination 2 requiredgG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
fastening method side-by-side mountingYes
fastening methodscrew fixing
height210 mm
width145 mm
depth202 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards20 mm
— upwards10 mm
— at the side10 mm
— downwards10 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
Connections/ Terminals
for main current circuitConnection bar
for auxiliary and control circuitscrew-type terminals
at contactor for auxiliary contactsScrew-type terminals
of magnet coilscrew terminal
width of connection bar25 mm
thickness of connection bar6 mm
diameter of holes11 mm
number of holes1
for AWG cables for main contacts2/0 ... 500 kcmil
stranded70 ... 240 mm²
solid or stranded0.5 ... 4 mm²
finely stranded with core end processing0.5 ... 2.5 mm²
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
— solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 1x 12
AWG number as coded connectable conductor cross section for auxiliary contacts18 ... 14
Safety related data
mirror contact according to IEC 60947-4-1Yes
positively driven operation according to IEC 60947-5-1No
suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with box terminal/cover

Accessories 38

Genuine accessories that can be used with the Siemens 3RT1065-6LA06 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
3RH1921-1DA11Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1EA11Aksesuar · Auxiliary switch · auxiliary switches
3RT1966-4EA1Aksesuar · Terminal covers · terminal covers
3RA1954-2AAksesuar · Mechanical interlocks · mechanical interlocks
3RT1966-4EA2Aksesuar · Terminal covers · terminal covers
3TX6546-3BAksesuar · Terminal covers · terminal covers
3RH1921-1JA11Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1KA11Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1EA02Aksesuar · Auxiliary switch · auxiliary switches
3RA1962-2AAksesuar · Base plates · base plates
3RT1966-4EA3Aksesuar · Terminal covers · terminal covers
3RH1921-1EA20Aksesuar · Auxiliary switch · auxiliary switches
3RT1916-4JA02Aksesuar · Miscellaneous accessories · insulation stops
3RA1963-2AAksesuar · Wiring modules, connectors and kits · link rails
3RT2900-1SB10Aksesuar · Miscellaneous accessories · labeling plates
3RT2926-1QT00Aksesuar · LED modules · LED display indicator modules
3RH1921-1KA20Aksesuar · Auxiliary switch · auxiliary switches
3RT1926-4MA10Aksesuar · Sealing covers · sealing covers
3RH1921-1KA02Aksesuar · Auxiliary switch · auxiliary switches
3RT2900-1SB20Aksesuar · Miscellaneous accessories · labeling plates
3RT2900-1SB60Aksesuar · Miscellaneous accessories · labeling plates
3RA1962-2EAksesuar · Base plates · base plates
3RH1981-1JA11Aksesuar · Auxiliary switch · auxiliary switches
3RH1981-1DA11Aksesuar · Auxiliary switch · auxiliary switches
3RT1966-4GAksesuar · Terminal covers · box terminal blocks
3RT1966-4BA31Aksesuar · Wiring modules, connectors and kits · coil connectors
3RT1955-4PA00Aksesuar · Terminal covers · connection methods
3RH1921-1CD10Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1CD01Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1CA10Aksesuar · Auxiliary switch · auxiliary switches
3RH1921-1CA01Aksesuar · Auxiliary switch · auxiliary switches
3RA1973-3EAksesuar · Wiring modules, connectors and kits · link rails
3RA1963-3EAksesuar · Wiring modules, connectors and kits · link rails
3RA1963-2BAksesuar · Wiring modules, connectors and kits · link rails
3RA1962-2FAksesuar · Base plates · base plates
3RH1921-1XA22-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RT1965-7AYedek parça · Arc chutes · arc chutes
3RT1965-6AYedek parça · Contact pieces and vacuum interrupters · contacts

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

MXS-AS16L
SMC MXS-AS16L
View Details

SMC

MXS-AS16L

MFR #MXS-AS16L

SKU #YLSAP0XXFGFSWY6

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
View Details

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
View Details

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
View Details

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

BC8M12
Brush Research Mfg BC8M12
View Details

Brush Research Mfg

BC8M12

MFR #BC8M12

SKU #YLSA0P5BE6ZJCIW

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

Related Searches

Siemens 3RT1065-6LA06 priceSiemens 3RT1065-6LA06 quotebuy Siemens 3RT1065-6LA063RT1065-6LA06 price3RT1065-6LA06 stock availabilitySiemens spare partsSiemens 3RT1065-6LA06 equivalentSiemens 3RT1065-6LA06 specifications